psig Sample Clauses

psig. Notwithstanding anything to the contrary herein, Buyer and Seller agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. Seller shall be responsible for transportation of Gas to, and duly tendering the Gas at, the Delivery Point(s). Buyer shall be responsible for transportation of Gas from the Delivery Point(s) and each Party assumes all liability therefor and shall indemnify, defend and hold harmless the other Party from any Claims, including injury to and death of persons, arising from any act or incident occurring in respect thereof. Buyer shall provide Seller notice of Maintenance Operations within a reasonably practicable time prior to the commencement thereof. Any reduction of Gas taken pursuant to a notice of Maintenance Operations shall not be considered a default.
AutoNDA by SimpleDocs
psig. Pressure expressed in pounds per square inch gauge.
psig. The Contractor shall provide a documented failsafe analysis of gas flow controls, related power supplies, backups, and interlocks. The Contractor shall select a single supplier of each category of instruments furnished. Additional suppliers for a given category will be considered only if the primary supplier cannot meet the design requirements for a specific instrument. All instruments shall bear an instrument data plate which gives the salient technical data for the instrument. The Contractor shall verify that all instruments and control devices are calibrated. Calibration shall be certified by an independent laboratory or agency with traceability to the National Bureau of Standards. The Contractor shall check control signal generation, transmission, reception and response for all control loops under simulated conditions. System electronics shall be shielded against electromagnetic interferences and shall be capable of withstanding surges in power supplies.
psig. The center section of the end xxxxxxx contain the bearings, oil deflectors and hydrogen seals.. The lower halves of the bearings are equipped with dual element thermocouples. The leads are connected through a quick disconnect through the end shield to allow ease of bearing removal. A three section inner and a two section outer oil deflector are bolted into the end shield and provide sealing of the oil along the shaft. The deflectors are either fabricated or cast aluminum. All faces of the deflectors have "O" ring grooves to provide additional protection from oil leaks. All annular areas formed between the set of teeth are designed to provide minimum pressure drops and have oil gutters machined in to prevent oil from backdripping on the shaft. The hydrogen seal casing and seals, which prevent hydrogen gas from escaping along the shaft utilize steel babbitted rings. Pressurized oil for the seals is supplied from the main oil system header to the seal oil control unit, where it is regulated. The seal oil control unit is factory assembled packaged system and is located in the collector end compartment and includes the following components: o Differential pressure regulator valve with bypass o Differential pressure gage (seal oil pressure vs casing gas pressure) and two differential pressure switches: one for alarm and one for actuating the DC emergency seal oil pump o Shut-off and isolation valves for operation and maintenance The connection end bearing and hydrogen seals are insulated from the rotor to prevent direct electrical contact between the rotor and the end shield. Both end xxxxxxx will have proximity type vibration probes. These are located axially outboard of the bearing. Mounting for velocity type vibration sensors is also provided on the surface of the bearing caps. All exiting wiring from the temperature indication devices and the insulating test leads are brought out of the unit through gas tight conex type seals to prevent any chance of a hydrogen leak.
psig. In the event that the average monthly working pressure at the point of delivery exceeds sixty (60) psig for more than two (2) consecutive months, for reasons other than Force Majeure, Seller shall have the right to terminate this contract.
psig. The proposed change does not impact the margin of safety included in the design pressure compared to the peak calculated pressure because the proposed activity does not alter, in any way, the available force provided by the tendons. Additionally, the proposed activity does not affect the initial temperature conditions within the Reactor Building assumed in the accident analysis for a steam line break. Therefore, this proposed change does not involve a significant reduction in a margin [of] safety. The NRC staff has reviewed the licensee’s analysis and, based on this review, it appears that the three standards of 10 CFR 50.92(c) are satisfied. Therefore, the NRC staff proposes to determine that the amendment request involves no significant hazards consideration.
AutoNDA by SimpleDocs
psig a. The testing apparatus shall be set-up such that there are two (2) connections, one for applying air to the rudder and the second for releasing air pressure. The test pressure gauge shall be in current calibration and shall be installed at the outlet connection. Additionally, a relief valve or U tube shall be installed as part of the test rig to prevent accidental over pressurization of the rudder.
psig. The City has applied for a point source implementation grant (“PSIG”) in the amount of up to approximately $7,000,000 from the Minnesota Pollution Control Agency (“MPCA”). If such grant is approved and received, the grant proceeds will be applied to grant- eligible Qualified Costs for stormwater facilities within the Property and shall reduce, redeem, defease or reimburse the City for the amount of City TIF Bond proceeds allocated to such Qualified Costs. The City and Developer will cooperate in meeting all PSIG requirements. The proceeds of the PSIG shall be deposited in the Disbursing Account in accordance with and subject to the Disbursing Agreement, or shall be retained by City and applied to reimburse the City or Authority for prior disbursements. The City will take bridge financing risk for the PSIG funds applied for and will not seek reimbursement from Developer if the PSIG is not awarded in whole or in part.‌
psig. Pound-force per square inch gauge, which is the pressure relative to atmospheric pressure. May 2017 C01025C17 Georgetown Wet Weather Treatment Station 15050 - 4 PIPING SYSTEMS
Time is Money Join Law Insider Premium to draft better contracts faster.