D Component, Sub Sample Clauses

D Component, Sub system and System Testing The Contractor shall provide support for rapid development of customized test fixtures, equipment, instrumentation test sets, and processes to evaluate system and sub-system conformance and performance of hardware, avionics and other aviation subassemblies; missiles and missile system components; radar assemblies, subassemblies and components; and other unique RTC customer assets. Support may include combining test efforts with RTC environmental capabilities to provide testing of assets while in extreme environments. The Contractor shall also provide support for distributed testing and hardware in the loop (HWIL) test capabilities, combining test and evaluation with modeling and simulation to support simulation based acquisition. Support will include operation of multiple HWIL facilities and the Distributed Test Control Center (DTCC), in addition to operation and utilization of the RTC High Performance Computing Center (HPCC) and other assets. Required services shall include engineering; software development, test design; modeling and simulation; transportation of test articles and materials, instrumentation, data processing/instrumentation calibration, on-site test participation, to include operation of test facilities and equipment; data reduction and analysis; and report preparation as it relates to system performance. The Contractor shall provide support for testing of missile and aviation system components to the requirements of associated technical data packages including relevant drawings, specifications, standards, contracts, technical documentation, and test plans. Components, sub-assemblies, and assemblies to be tested shall include electrical, mechanical, and electro-mechanical parts necessary for both currently fielded and planned missile and aviation systems. Support will be required for visual inspection (for workmanship, quality conformance, proper markings and identification, dimensional conformance, and physical characteristics as called out in the Technical Data Package (TDP)) and functional testing that will include determining proper test setups necessary for a wide range of electrical and mechanical items, selecting, connecting, and operating test equipment for test setups, preparing/modifying test setups as necessary to meet the requirements of the TDP and test plan, preparation of components for testing (i.e. disassembly of mechanical components), conducting tests, and recording data and reporting results. T...
AutoNDA by SimpleDocs

Related to D Component, Sub

  • Third Party Components The Products and Services may contain third party components (including open source software) subject to separate license agreements. To the limited extent a third party license expressly supersedes this XXXX, such third party license governs Customer’s use of that third party component.

  • Sub-Loop In locations where SBC-AMERITECH has deployed: (1) Digital Loop Carrier systems and an uninterrupted copper loop is replaced with a fiber segment or shared copper in the distribution section of the loop; (2) Digital Added Main Line (“DAML”) technology to derive multiple voice-grade POTS circuits from a single copper pair; or (3) entirely fiber optic facilities to the end user, SBC-AMERITECH will make the following options available to CLEC:

  • Household Component The Medical Expenditure Panel Survey (MEPS) provides nationally representative estimates of health care use, expenditures, sources of payment, and health insurance coverage for the U.S. civilian non-institutionalized population. The MEPS Household Component (HC) also provides estimates of respondents’ health status, demographic and socio-economic characteristics, employment, access to care, and satisfaction with health care. Estimates can be produced for individuals, families, and selected population subgroups. The panel design of the survey, which includes 5 Rounds of interviews covering 2 full calendar years, provides data for examining person level changes in selected variables such as expenditures, health insurance coverage, and health status. Using computer assisted personal interviewing (CAPI) technology, information about each household member is collected, and the survey builds on this information from interview to interview. All data for a sampled household are reported by a single household respondent. The MEPS-HC was initiated in 1996. Each year a new panel of sample households is selected. Because the data collected are comparable to those from earlier medical expenditure surveys conducted in 1977 and 1987, it is possible to analyze long-term trends. Each annual MEPS-HC sample size is about 15,000 households. Data can be analyzed at either the person or event level. Data must be weighted to produce national estimates. The set of households selected for each panel of the MEPS HC is a subsample of households participating in the previous year’s National Health Interview Survey (NHIS) conducted by the National Center for Health Statistics. The NHIS sampling frame provides a nationally representative sample of the U.S. civilian non-institutionalized population and reflects an oversample of blacks and Hispanics. In 2006, the NHIS implemented a new sample design, which included Asian persons in addition to households with black and Hispanic persons in the oversampling of minority populations. MEPS further oversamples additional policy relevant sub- groups such as low income households. The linkage of the MEPS to the previous year’s NHIS provides additional data for longitudinal analytic purposes.

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame (MDF) to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (DAMLs), and may have up to 6,000 feet of bridged tap between the End User’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For Loops less than 18,000 feet and with less than 1300 Ohms resistance, the Loop will provide a voice grade transmission channel suitable for Loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point.

  • Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and its cross-box (or other access point) that serves an end user location.

  • Separation of Components The SOFTWARE PRODUCT is licensed as a single product. Its component parts may not be separated for use on more than one computer.

  • Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the End User’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the End User and the cross-box.

  • Unbundled Sub-Loop Distribution Intrabuilding Network Cable (USLD-INC) is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross connect device in the building equipment room up to and including the point of demarcation at the End User’s premises.

  • Program Components Activities and services delivered under this Program Element align with Foundational Programs and Foundational Capabilities, as defined in Oregon’s Public Health Modernization Manual, (xxxx://xxx.xxxxxx.xxx/oha/PH/ABOUT/TASKFORCE/Documents/public_health_modernization_man ual.pdf) as well as with public health accountability outcome and process metrics (if applicable) as follows:

  • Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters).

Time is Money Join Law Insider Premium to draft better contracts faster.