The Unbundled Sub-Loop clause defines the terms under which a telecommunications provider grants another provider access to a specific segment of its local loop infrastructure, typically between a central office and a customer's premises. This clause outlines the technical and operational requirements for accessing and maintaining the sub-loop, such as demarcation points, service quality standards, and procedures for installation or repair. Its core function is to facilitate competition by enabling multiple service providers to use portions of the existing network, thereby promoting consumer choice and efficient use of infrastructure.
Unbundled Sub-Loop. Feeder (USLF) provides connectivity between BellSouth's central office and its cross-box (or other access point) that serves an end user location.
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscriber’s building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
2.7.4.1 In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25-pair increments for SouthEast’s use on this cross-connect panel. SouthEast will be responsible for connecting its facilities to the 25-pair cross-connect block(s).
Unbundled Sub-Loop. (distribution facilities)
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscribers’ building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscriber’s building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
2.7.4.1 In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25-pair increments for <<customer_name>>’s use on this cross-connect panel. <<customer_name>> will be responsible for connecting its facilities to the 25-pair cross-connect block(s).
Unbundled Sub-Loop. Feeder Loop, 2 Wire Loop-Start, Voice Grade - Zone 2 UEA USBFB 18.35 122.52 46.61 149.46 59.37 19.99 19.99 19.99
Unbundled Sub-Loop. Feeder Loop, 4 Wire Loop-Start, Voice Grade - Zone 3 UEA USBFE 41.37 226.36 144.28 19.99 19.99 19.99 19.99 Order Coordination For Specified Conversion Time, Per LSR UEA OCOSL 45.34 Unbundled ▇▇▇-▇▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇, ▇ ▇▇▇▇ ▇▇▇▇ ▇▇▇ - ▇▇▇▇ ▇ ▇▇▇ USBFF 19.63 202.01 105.88 19.99 19.99 19.99 19.99
Unbundled Sub-Loop. Modification Unbundled Sub-Loop Modification - 2-W Copper Dist Load Coil/Equip Removal per 2-W PR UEF ULM2X $355.71 $12.26 $18.94 $8.42 Unbundled Sub-loop Modification - 4-W Copper Dist Load Coil/Equip Removal per 4-W PR UEF ULM4X $355.71 $12.26 $18.94 $8.42 Unbundled Sub-loop Modification - 2-w/4-w Copper Dist Bridged Tap Removal, perPR unloaded UEF ULM4T $560.55 $14.30 $18.94 $8.42 Unbundled Network Terminating Wire (UNTW) Unbundled Network Terminating Wire (UNTW) per Pair UENTW UENPP $1.37 $2.48 $2.48 $1.74 $1.74 $18.94 $8.42 Network Interface Device (NID) Network Interface Device (NID) - 1-2 lines UENTW UND12 $86.46 $56.75 $18.94 $8.42 Network Interface Device (NID) - 1-6 lines UENTW UND16 $127.93 $98.21 $18.94 $8.42 Network Interface Device Cross Connect - 2 W UENTW UNDC2 $11.73 $11.73 $18.94 $8.42 Network Interface Device Cross Connect - 4W UENTW UNDC4 $11.73 $11.73 $18.94 $8.42 CATEGORY NOTES UNBUNDLED NETWORK ELEMENT Interim Zone BCS USOC RATES OSS RATES Charge - Charge - Svc Order Svc Order Incremental Incremental Manual Svc Manual Svc Submitted Submitted Charge - Manual Charge - Manual Order vs. Order vs. Elec Manually per Svc Order vs. Svc Order vs. Electronic-Disc Electronic-Disc per LSR LSR Electronic-1st Electronic-Add'l 1st Add'l Nonrecurring Nonrecurring Disconnect Recurring First Add'l First Add'l SOMEC ▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇ Unbundled Loop Concentration - System A (TR008 ULC UCT8A $441.42 $650.81 $650.81 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - System B (TR008 ULC UCT8B $52.97 $271.17 $271.17 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - System A (TR303 ULC UCT3A $478.93 $650.81 $650.81 Unbundled Loop Concentration - System B (TR303 ULC UCT3B $89.26 $271.17 $271.17 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - DS1 Loop Interface Car ULC UCTCO $5.04 $126.57 $92.14 $33.57 $9.40 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - ISDN Loop Interface (Brite Card UDN ULCC1 $8.00 $21.07 $20.96 $10.78 $10.71 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - UDC Loop Interface (Brite Card UDC ULCCU $8.00 $21.07 $20.96 $10.78 $10.71 $19.99 $19.99 $19.99 $19.99 Unbundled Loop Concentration - -2 Wire Voice-Loop Start or Ground Start LoopInterface (POTS Card) UEA ULCC2 $2.00 $21.07 $20.96 $10.78 $10.71 $18.94 $8.42 Unbundled Loop Concentration - 2 Wire Voice - Reverse Battery Loop Interface(SPOTS Card) UEA ULCCR $11.89 $21.07 $20.96 $10.78 $10.71 $18.94 $8.42 Unbundled Loop Concentrat...
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscriber’s building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
2.7.4.1 In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25-pair increments for Wakul’s use on this cross-connect panel. Wakul will be responsible for connecting its facilities to the 25-pair cross-connect block(s).
Unbundled Sub-Loop. Intrabuilding Network Cable (USL-INC) (a.k.a. riser cable) is the distribution facility inside a subscriber’s building or between buildings on one customer’s same premises (continuous property not separated by a public street or road). USL-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation, at the end user’s premises.
2.7.4.1 In a scenario that requires connection in a building equipment room, BellSouth will install a cross connect panel for the purpose of accessing USL-INC pairs. The cross-connect panel will function as a single point of interconnection (SPOI) for USL-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25-pair increments for Metro FiberLink, Inc.’s use on this cross-connect panel. Metro FiberLink, Inc. will be responsible for connecting its facilities to the 25-pair cross-connect block(s).