Equipment Housing services Sample Clauses

Equipment Housing services. Guaranteed power Power is key to your operation in our data centres. Without a reliable power supply, you cannot operate. Interxion has taken extensive measures to equip its data centres with a reliable and resilient power infrastructure, including diesel generators with sufficient fuel storage, UPS systems, various redundant elements in the distribution network throughout our building, as well as effective escalation procedures and 24x7 support in case of problems. The Equipment Housing service provides various solutions for your power needs. The following power options are available, although these may vary per data centre due to local customs and/or regulations. • AC power voltage: 230 Volt single phase or 400 Volt three phase • AC 230 V power breakers: 6, 16 or 32 Ampere (Zurich 13 A) • DC power voltage: 48 Volt, DC power breakers: various sizes Power is provided per plug or plug set which Interxion installs under the raised floor at the location of the cabinet position or at the points in the Cage or Suite as requested by the Customer. The AC and DC power point of supply is at the installed plug or plug set, as indicated in Schedule 4 by “SLA Demarcation Line”. Distribution of power from the supply point onwards is the responsibility of the Customer, subject to the following restrictions. Power usage is either included as a flat rate in the monthly rental charges for the plug or plug set, or is measured separately by a customer specific kWh meter. Private rooms and Suites are by default equipped with a kWh meter. Cages and Cabinet positions do not have kWh meters, although these can be installed on request at additional cost to the customer. Max usage of a power plugset: The current drawn from the plugset shall not exceed a total maximum continuous load of 70% from one rated MCB (Miniature Circuit Breaker) For instance, the total continuous current drawn from a 16 Amp breaker plugset shall not exceed a maximum of 11.2 Amp. Compliance with this requirement will be measured by for instance the following methods: • Once a month a check with a clamp meter measuring and confirming the contractually agreed continuous current in Amps. • Once a month read the kWh meters (11.2 A * 230V* 24hrs * 30 days/1000 = 1,855 kWh/month) In case of a customer specific meter, power usage is metered according to the terms in and charged at the price as defined in the Service Form. In most locations, Intention offers three different service levels to meet your individual Equ...
AutoNDA by SimpleDocs

Related to Equipment Housing services

  • SERVICES AND EQUIPMENT Section 21.01. Landlord shall, at its cost and expense:

  • Installation Services 3.1 The Bitstream 2a Service includes a Standard Install as set out below (in each case to the extent that the relevant provisioning works are not already complete for the relevant Service Order).1

  • Hospice Services Services are available for a Member whose Attending Physician has determined the Member's illness will result in a remaining life span of six months or less.

  • Office Equipment The Client must not install any cabling, IT or telecom connections without the Provider’s consent, which the Provider may refuse at its absolute discretion. As a condition to the Provider’s consent, the Client must permit the Provider to oversee any installations (for example IT or electrical systems) and to verify that such installations do not interfere with the use of the accommodation(s) by other Clients or the Provider or any landlord of the building.

  • Monitoring Services IDT staff shall, using methods that include face-to-face and other contacts with the member, monitor the services a member receives. This monitoring shall ensure that:

  • Construction Services 4,500 thousand SDR for Japan Post in Group A 15,000 thousand SDR for all other entities in Group A 4,500 thousand SDR for entities in Group B Architectural, engineering and other technical services covered by this Agreement: 450 thousand SDR Other services: 130 thousand SDR List of Entities which procure the services, specified in Annex 4:

  • Collection Services 5.01 General 5-1 5.02 Solid Waste Collection 5-1 5.03 Targeted Recyclable Materials Collection 5-3

  • Financing Services The Manager shall:

  • Dining Services Meal Plan and applicable Dining Services policies are as stated herein. Any questions regarding Resident’s Meal Plan or Torero ID Card should be directed to Campus Card Services: xxxxxxxxxx@xxxxxxxx.xxx or (000) 000-0000.

  • Hosting Services 13.1 If Supplier or its subcontractor, affiliate or any other person or entity providing products or services under the Contract Hosts Customer Data in connection with an Acquisition, the provisions of Appendix 1, attached hereto and incorporated herein, apply to such Acquisition.

Time is Money Join Law Insider Premium to draft better contracts faster.