Circuit Breaker Sample Clauses

Circuit Breaker. All expenditures that shall incurred towards packing, transport, inspection, testing charges etc. are to be borne by the PIA.
AutoNDA by SimpleDocs
Circuit Breaker. Bank, in its discretion, through the Compensation Committee, may decide that there will be no payout in a given year until the level of net income (as reported in the Corporation’s financial statements) earned from each business is at least $2 million (or the level determined in the future by the Board of the Corporation).
Circuit Breaker. To install and maintain in good working condition at the Tenant's expense the circuit breaker(s) to the Tenant's electricity supply which are installed in the Premises and if the Tenant shall fail for whatever reason to install or maintain the same, then the Landlord may do so and the costs of installation and/or maintenance shall be a debt due from the Tenant to the Landlord and be recoverable forthwith as such. For the avoidance of doubt, the Tenant shall not be liable to maintain any other circuit breakers which are not installed in the Premises, notwithstanding that the same may be installed in relation to the electricity supply to the Premises.
Circuit Breaker. As of the Measurement Date, no unearned RSUs may become Earned RSUs if as of such date there exists a material weakness in safety, soundness or compliance (e.g., a regulatory memorandum of understanding), at the Company level or the Bank level, as determined in the sole discretion of the Committee (a “Circuit Breaker”), such that a Circuit Breaker at the Bank level shall prevent the earning of RSUs for Participants employed by such Bank and that a Circuit Breaker at the Company level shall prevent the earning of RSUs by all Participants as of the Measurement Date; provided, however, that in the event a Circuit Breaker exists, RSUs that would become Earned RSUs but for the existence of the Circuit Breaker shall not be forfeited as of the Measurement Date, and may become Earned RSUs if the Circuit Breaker ceases to exist in its entirety prior to the second anniversary of the Measurement Date.
Circuit Breaker. Is anything else in the room failing to turn on? If so, check your service panel (breaker/fuse box) for a tripped breaker or blown fuse.
Circuit Breaker. Each apartment has a circuit breaker box in the kitchen. If an electric outlet becomes overloaded, it automatically throws the circuit off. If this happens, wait a few minutes, then locate which switch shut off. Make sure whatever caused the overload has been removed and then flip the switch back on.
Circuit Breaker i. Circuit breaker shall be three poles, single throw, air breaker type with stored energy, trip free mechanism & shunt trip. The circuit breaker of the outgoing feeder shall have an in built microprocessor base release, short circuit, over current & earth fault protection release.
AutoNDA by SimpleDocs
Circuit Breaker. Make - As per approved make. Type - Microprocessor release air circuit breaker Rated voltage - 415 Volts Rated frequency - 50 Hz Rated current - 1600/( Icu=Icf=1sec 50 kA) 800A(Icu=Icf=1sec 50 kA) No. of pole - 3 Aux. Voltage for trip/close coil - 110 V DC Motor for spring charging Voltage - 240 V AC Protection unit - Equivalent to SR-18G with fault indication & thermal masonry. Interlocking arrangement electrically & mechanically with bus coupler & incomer. PROTECTION (FOR LT SUPPLY 415V PANEL) The minimum protection to provided for different type of circuit are listed below :- INCOMING FEEDER :-
Circuit Breaker. As defined by the National Fire Protection Association-70 2020 National Electric Code, a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
Circuit Breaker. Services to be performed as part of scheduled circuit breaker preventative maintenance:  Tag out system at main breaker prior to starting any electrical work.  Open breaker, rack it out.  Check and exercise circuit breaker tripping system.  Clean any accumulation of dust or dirt from the circuit breaker.  Label all circuit breakers in English and French as required.  Inspect all wiring inside the panel. Repair and replace any wires that shows frays or discoloration.  Remove tag out from the main breaker. Put on the breaker.  Record voltage and amperage from main distribution. Report electrical voltage and amerage to FAC for analysis. Contractor shall not change voltage and amperage.  Inspect connections for tightness, inspect for damaged connections. Report damaged connection to FAC.  Check for the presence of ground currents, evaluate and resolve defective circuits (a defective circuit that has a ground current).  Make sure grounding resistance is less than 25 ohms. If not less than 25 ohms, report to FAC.  Remove tags/locks.  List all materials and record the data used in the log book.  Clean-up work space.