Apparatus Bays Sample Clauses

Apparatus Bays. The Station shall require two (2) apparatus bays of equal size and overall construction. Design shall include an add-alternate within the design for these bays to be “drive-through” bays with motorized, overhead (OH) doors on two sides enabling the apparatus to enter and exit without backing up. The Apparatus Bays shall not face north nor shall it be subject to shade allowing for snow and ice build- up. OH door operators shall be equipped with extenders at both tracks of each OH door to accommodate the height of apparatus bumpers. Fire personnel shall be able to manually open the OH doors in the event of power outage or motor failure. All design of OH door opening shall include indicator lights at each side of the OH door opening, programmed to indicate door void of opening to maneuver the apparatus. The bays shall measure, at a minimum, 80’ deep and 20’ wide. The design shall also include an operator extender which will extend the frequency of the OH door operators, allowing an OH door to initiate opening at a further distance from the Station. A training wall shall be incorporated into the design of the Apparatus Bays with sufficient height, anchors, and break-away openings to perform typical fire drill procedures, including technical rescue training. No mechanical, electrical or plumbing systems shall be located on the training wall. Apparatus bays shall include full-length trench drains, parallel and centrally located in the floor of each Apparatus bay with a prominent, positive slope, extending to the perimeter of the engine truck, to promote drainage. Steps shall be taken by the Consultant to ensure the concrete in Apparatus Bays shall be delivered to the Owner, aesthetically appealing, functional and damage free. No center, roof support shall be permitted between Apparatus Bays. The roof shall clear-span both Apparatus Bays. First-In Fire Alerting system shall be designed and installed by Low Voltage Incorporated (LVI) and incorporated into the Consultants plans and specifications. Consultant shall coordinate all design information with LVI. All Apparatus Bays shall be equipped with a building exhaust system and Plymovent vehicle exhaust removal system by Complete Air Systems. Consultant shall coordinate all design information with Complete Air Systems. Dropped from the ceiling, over-head, compressed air and electrical connections suitable for regular operations and apparatus (medic requires specialty plug) charging shall be provided within the desi...
AutoNDA by SimpleDocs

Related to Apparatus Bays

  • Appliances The Landlord shall: (check one) ☐ - Provide the following appliances: . ☐ - Not provide any appliances.

  • Structures Airport facilities such as bridges; culverts; catch basins, inlets, retaining walls, cribbing; storm and sanitary sewer lines; water lines; underdrains; electrical ducts, manholes, handholes, lighting fixtures and bases; transformers; flexible and rigid pavements; navigational aids; buildings; vaults; and, other manmade features of the airport that may be encountered in the work and not otherwise classified herein. 10-50 SUBGRADE. The soil which forms the pavement foundation.

  • Fittings 3.2.1 Landing gear support structure and attachment fitting

  • Devices BNY Mellon will restrict the transfer of Customer Data from its network to mass storage devices. BNY Mellon will use a mobile device management system or equivalent tool when mobile computing is used to provide the services. Applications on such authenticated devices will be housed within an encrypted container and BNY Mellon will maintain the ability to remote wipe the contents of the container.

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Architecture The Private Improvements shall have architectural features, detailing, and design elements in accordance with the Project Schematic Drawings. All accessory screening walls or fences, if necessary, shall use similar primary material, color, and detailing as on the Private Improvements.

  • Fire Fighting Costs of operating and maintaining the fire-fighting equipments and personnel, if any.

  • Firmware The Contractor shall deliver firmware required for production acceptance testing in accordance with CDRL A009 Contractor’s Supplier Configuration Management Plan. The Contractor shall use Government furnished software for testing. Deliverable Data Item (See DD-1423): CDRL A009: “Contractor’s Supplier Configuration Management Plan”

  • Electrical Provide drawings for the following systems:

  • Fencing The SPD shall Fence the demarcated boundary of the Demised Premises at the SPD’s own expense in every respect.

Time is Money Join Law Insider Premium to draft better contracts faster.