CONSTRUCTION QUALITY CONTROL PLAN (CQCP) Sample Clauses

CONSTRUCTION QUALITY CONTROL PLAN (CQCP). The Contractor shall provide a Construction Quality Control Plan (CQCP) and quality control manager which is the performance of the tasks that ensure that construction is performed according to Arlington County and WMATA Technical Specifications, drawings, requisitions, codes of practices, construction procedures and other technical documents referenced in contractual documents on time, within a defined budget, and a safe work environment. The CQCP shall be consistent with the FTA-IT-90-5001-02.1 and ISO 9001:2008 standards or any update thereto. The CQCP shall address quality assurance in organization, oversight, design, development, installation, inspection, review, and record keeping. WMATA shall be copied on all quality control documents and test results related to the Project. The Contractor shall create the CQCP and name one individual as quality control manager for the Project. The quality control manager’s sole duties on the Project shall be to provide quality control management independent of construction and profit. The quality control manager shall be responsible for all quality control activities and act as the primary contact on quality control issues. The quality control manager must report directly to someone at least one level above the General Contractor’s Project Manager and Superintendent. The quality control manager must be a professional engineer with sufficient experience and expertise to perform the duties required of such a role. The CQCP shall be provided prior to the start of construction and are subject to WMATA’s approval as part of the approved Construction Documents. The CQCP shall be as listed below: • CQC Plan Cover Sheet • CQC Plan AcknowledgementOrganizational Chart • Resumes and Certifications Documentation • Quality Control Manager Responsibility • Stop Work Authorization Letter • Major Definable Features of Work • Three Phases of Inspection • Quality Control Testing and Verifications • Tests and Records • Testing Agency Schedule • Submittals • Tracking Deficiencies • Contractor’s Quality Control Report (CQCR) • Non-Conformance Report • Construction Punch List • Weekly QA/QC Meeting MinutesPreparatory Meeting Checklist • Initial Inspection Checklist • Receiving Material Inspection ReportContractor Quality Control Worksheet
AutoNDA by SimpleDocs

Related to CONSTRUCTION QUALITY CONTROL PLAN (CQCP)

  • Quality Control Plan Within forty five (45) days after the design development documents are approved, the Design-Builder shall develop a quality control plan for the Project (the “Quality Control Plan”). A draft of the Quality Control Plan shall be submitted to the Department and shall be subject to the Department’s review and approval. The Quality Control Plan shall be tailored to the specific products/type of construction activities contemplated by the GMP Basis Documents, and in general, shall include a table of contents, quality control team organization, duties/responsibilities of quality control personnel, submittal procedures, inspection procedures, deficiency correction procedures, documentation process, and a list of any other specific actions or procedures that will be required for key elements of the Work.

  • Quality Control Program The Contractor shall describe the Quality Control Program in a written document which shall be reviewed by the Engineer prior to the start of any production, construction, or off-site fabrication. The written Quality Control Program shall be submitted to the Engineer for review at least ten (10) calendar days before the start of construction. The Quality Control Program shall be organized to address, as a minimum, the following items:

  • Quality Assurance/Quality Control Contractor shall establish and maintain a quality assurance/quality control program which shall include procedures for continuous control of all construction and comprehensive inspection and testing of all items of Work, including any Work performed by Subcontractors, so as to ensure complete conformance to the Contract with respect to materials, workmanship, construction, finish, functional performance, and identification. The program established by Contractor shall comply with any quality assurance/quality control requirements incorporated in the Contract.

  • Quality Control A. Controlled Affiliate agrees to use the Licensed Marks and Name only in connection with the licensed services and further agrees to be bound by the conditions regarding quality control shown in attached Exhibit A as they may be amended by BCBSA from time-to-time.

  • Construction Management Plan Contractor shall prepare and furnish to the Owner a thorough and complete plan for the management of the Project from issuance of the Proceed Order through the issuance of the Design Professional's Certificate of Material Completion. Such plan shall include, without limitation, an estimate of the manpower requirements for each trade and the anticipated availability of such manpower, a schedule prepared using the critical path method that will amplify and support the schedule required in Article 2.1.5 below, and the Submittal Schedule as required in Article 2.2.3. The Contractor shall include in his plan the names and resumés of the Project Superintendent, Project Manager and the person in charge of Safety.

  • COUNTY’S QUALITY ASSURANCE PLAN The County or its agent will evaluate the Contractor’s performance under this Contract on not less than an annual basis. Such evaluation will include assessing the Contractor’s compliance with all Contract terms and conditions and performance standards. Contractor deficiencies which the County determines are severe or continuing and that may place performance of the Contract in jeopardy if not corrected will be reported to the Board of Supervisors. The report will include improvement/corrective action measures taken by the County and the Contractor. If improvement does not occur consistent with the corrective action measures, the County may terminate this Contract or impose other penalties as specified in this Contract.

  • Construction, Etc Each covenant contained herein shall be construed (absent express provision to the contrary) as being independent of each other covenant contained herein, so that compliance with any one covenant shall not (absent such an express contrary provision) be deemed to excuse compliance with any other covenant. Where any provision herein refers to action to be taken by any Person, or which such Person is prohibited from taking, such provision shall be applicable whether such action is taken directly or indirectly by such Person. For the avoidance of doubt, all Schedules and Exhibits attached to this Agreement shall be deemed to be a part hereof.

  • Use; Quality Control a. Neither party may alter the other party’s trademarks from the form provided and must comply with removal requests as to specific uses of its trademarks or logos.

  • Construction Administration Phase Delete the following paragraph if Submittal Exchange isn’t going to be used: 2.2.2.

  • Construction Phase - Administration of the Construction Contract 1.6.1 The Construction Phase shall commence with the acceptance of the Construction Manager’s Guaranteed Maximum Price (or acceptance of a partial Guaranteed Maximum Price for a stage or phase) and issuance of a Notice to Proceed with Construction Services and terminate sixty (60) days after Final Payment to the Contractor is made, or when all of Architect/Engineer’s services have been satisfactorily performed, whichever occurs later.

Time is Money Join Law Insider Premium to draft better contracts faster.