Backup Solution Sample Clauses

Backup Solution. Integrated Backup Appliance: Qty=02 (Primary and DR) Product Name Quantity Integrated Backup Appliance (Primary and DR) DP4400-48TB 2 Continuous Data Protection and Replication Solution for VMs/ Socket 14 License Criteria Architecture Purpose built integrated backup appliance based on software defined/vmware based backup server and backup storage with native capability of data deduplication Capacity 48TB usable capacity (post-RAID capacity ignoring dedupe factor) with in-line, variable length global deduplication (i.e. global deduplication irrespective of number of logical containers or backup devices created/used in the system) Scalability Should provide data in place upgrade and scalability to 90TB or more post-RAID capacity in the same chassis in 2u form factor. Can use object storage as external tier for long term retention. Protection and Fault Tolerance Must have robust FT and self healing mechanism. E.g. RAID with hotspare, end-to-end verification without performance degradation, snapshots to protect against physical and logical failures . System should be able to survive double disk failure. Proposed model should support to be deployed/upgraded to redundant controller for High Availability. Cleanup/Housekeeping System should have seamless self-maintenance and housekeeping mechanism (e.g. cleanup, garbage collection) Deduplication Technology Solution should offer In-line variable length and global dedulication. Solution must also support source side deduplication and any required deduplication license(s) must be included. Connectivity Should have 10G/1GbE. Must support IPv4, IPv6. Protocols Should support multiple backup protocols (NFS, CIFS, Boost and any other recommended proprietary protocol) simultaneously. All protocol licenses must be included. Throughput Can handle 8TB/Hr or more throughput using the proposed protocol(s) Application/DB Direct Integration Support Should support integration with industry leading native utilities (Oracle RMAN, BR*Tools, MSSQL backup) Platforms Compatibility Should support integration with open systems, and any other specialized platforms Security and Encryption Should support strong encryption of data-at-rest/in replication. Required license should be included. Solution must meet compliance standards Replication Network optimized replication with capability of bandwidth throttling. Solution must support 1:1, many:1, 1:many, and cascaded replication. Required replication license(s) should be included for entire c...
AutoNDA by SimpleDocs

Related to Backup Solution

  • Workstation Encryption Supplier will require hard disk encryption of at least 256-bit Advanced Encryption Standard (AES) on all workstations and/or laptops used by Personnel where such Personnel are accessing or processing Accenture Data.

  • Problem/ Solution Statement Problem California’s forest health crisis is an emergency of unprecedented scope and scale, with disastrous implications for the state’s environment, economy, energy systems, and human life. Unlike essentially all other technologies and solutions proposed to respond to the crisis, gasification has the potential to process forest waste in a way that extracts value and sequesters a large portion of its carbon. Before the recipient’s development of the pre- commercial Powertainer technology, no one had developed gasification technology that could economically respond to the problem. As a result, there have not yet been any large-scale deployments of distributed, commercial-scale gasification technology. The acceleration of tree mortality and persistent drought conditions make finding solutions to this problem more critical with each passing day.

  • Solution The Supplier’s contractually committed technical approach for solving an information technology business objective and associated Requirements as defined and authorized by the scope of the Contract or any order or Statement of Work issued under the Contract. Solution means all Supplier and Supplier’s third-party providers’ components making up the Solution, including but not limited to Software, Product, configuration design, implementation, Supplier-developed interfaces, Services and Work Product.

  • B1 The Specification B1.1 In consideration of the Contractor supplying the Services during the Contract Period in accordance with the Authority’s requirements as set out in the Specification and the provisions of the Contract the Contractor shall be paid the Contract Price.

  • Data Encryption Contractor must encrypt all State data at rest and in transit, in compliance with FIPS Publication 140-2 or applicable law, regulation or rule, whichever is a higher standard. All encryption keys must be unique to State data. Contractor will secure and protect all encryption keys to State data. Encryption keys to State data will only be accessed by Contractor as necessary for performance of this Contract.

  • Interface A defined set of transmission facilities that separate Load Zones and that separate the NYCA from adjacent Control Areas. Investor-Owned Transmission Owners. A Transmission Owner that is owned by private investors. At the present time these include: Central Xxxxxx Gas & Electric Corporation, Consolidated Edison Company of New York, Inc., New York State Electric & Gas Corporation, Niagara Mohawk Power Corporation, Orange and Rockland Utilities, Inc., and Rochester Gas and Electric Corporation.

  • Workstation/Laptop encryption All workstations and laptops that process and/or store DHCS PHI or PI must be encrypted using a FIPS 140-2 certified algorithm which is 128bit or higher, such as Advanced Encryption Standard (AES). The encryption solution must be full disk unless approved by the DHCS Information Security Office.

  • Workspace Whenever an academic or student union building is planned for construction or renovation, there shall be consideration of the needs for office space of graduate student employees in relevant departments. The University shall provide to all graduate student employees an on-campus mailbox. With approval of their department chair, graduate student employees shall be given key access into the buildings in which their offices or labs are housed for the purpose of performing assistantship work in said office or lab which is permitted by the department chair to be done outside of regular business hours. Department chairs may deny key access into buildings and/or offices/labs in order to minimize access to confidential materials or to minimize the risk of theft, fire/explosion hazards, personal harm, and other security/safety issues. Denial shall not be arbitrary or capricious. If key access is denied, the reason will be provided to the graduate student employee(s) involved. All departmental policies related to the issuance of keys to TOs shall apply equally to TOs in the Division of Continuing Education. Graduate student employees shall have reasonable access to photocopiers for copying related to their employment within departmental guidelines for usage. The parties agree to the creation of a joint committee, composed of equal numbers of representatives of the Union and the University, that will attempt to develop a plan to provide appropriate telephone access for bargaining unit members in connection with their employment responsibilities. The University will provide to this committee a report on the offices assigned to bargaining unit members during the 2005-2006 academic year and the proximity of those offices to a University telephone available for use by the respective bargaining unit member.

  • Health plan specification The Employer will require health plans participating in the Group Insurance Program to develop and implement health promotion and health education programs for State employees and their dependents.

  • Signaling Parameters All SS7 signaling parameters will be provided in conjunction with traffic exchange trunk groups, where and as available. These parameters include Automatic Number Identification ("ANI"), Calling Party Number ("CPN"), Privacy Indicator, calling party category information, originating line information, charge number, etc. Also included are all parameters relating to network signaling information, such as Carrier Information Parameter ("CIP"), wherever such information is needed for call routing or billing. GTE will provide SS7 via GR-394-SS7 and/or GR-317-SS7 format(s).

Time is Money Join Law Insider Premium to draft better contracts faster.