Technology Support Rooms and Riser. All technology support rooms will be provided with electronic access control and building optional standby power. Local UPS units will be provided where equipment cannot go offline. The support rooms should be located central to the areas that they serve and have clear access to cable pathways coming in and out of the rooms. The Building Entrance Facility (BEF) will be dedicated to incoming Telecommunications Service Provider, Tenant and Interbuilding services and will include the building demarcation point will be in this room. The Main Technology Room (MTR) will provide a protected environment for terminating all building-related backbone cables. This room is where the building Technology systems connect to the BEF and distribute to the TRs throughout the building. Two Technology Rooms (TRs) will be located on each floor and will contain adequate space for the technology riser and additional wall space for small quantities of network equipment required for building-related services such as voice/data, access control, DocuSign Envelope ID: 93B39195-D5C3-430B-8A8C-CCAC6E53AEA8 Aggie Square – Phase 1 UC Xxxxx, Sacramento Campus, CA LSTE - W surveillance cameras and building automation systems. The TRs will be stacked vertically to accommodate day one and future telecommunications service cabling from the BEF to each tenant space.
AutoNDA by SimpleDocs
Technology Support Rooms and Riser. All technology support rooms will be provided with electronic access control and building optional standby power. Local UPS units will be provided where equipment cannot go offline. The support rooms should be located central to the areas that they serve and have clear access to cable pathways coming in and out of the rooms. The Building Entrance Facility (BEF) will be dedicated to incoming Telecommunications Service Provider, Tenant and Interbuilding services and will include the building demarcation point will be in this room. The Main Technology Room (MTR) will provide a protected environment for terminating all building-related backbone cables. This room is where the building Technology systems connect to the BEF and distribute to the TRs throughout the building. Two Technology Rooms (TRs) will be located on each floor and will contain adequate space for the technology riser and additional wall space for small quantities of network equipment required for building-related services such as voice/data, access control, surveillance cameras and building automation systems. The TRs will be stacked vertically to accommodate day one and future telecommunications service cabling from the BEF to each tenant space.

Related to Technology Support Rooms and Riser

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Technical Support Services 2.1 The technical support services (the "Services"): Party A agrees to provide to Party B the relevant services requested by Party B, which are specified in Exhibit 1 attached hereto ("Exhibit 1").

  • Operations Support Systems Functions CBT shall provide CLEC, upon CLEC's request, nondiscriminatory access to CBT's Operations Support Systems functions for pre-ordering, ordering, provisioning, maintenance and repair and billing, in accordance with the terms and schedules established in the Commission’s Arbitration Award in Case No. 97-152-TP-ARB, August 14, 1997 (“Arbitration Award”). CBT shall provide CLEC advance written notice of any material changes to CBT operating support systems functions.

  • Operational Support Systems (OSS 2.13.1 BellSouth has developed and made available the following electronic interfaces by which <<customer_name>> may submit LSRs electronically. LENS Local Exchange Navigation System EDI Electronic Data Interchange TAG Telecommunications Access Gateway

  • Maintenance and Support Services As long as you are not using the Help Desk as a substitute for our training services on the Tyler Software, and you timely pay your maintenance and support fees, we will, consistent with our then-current Support Call Process:

  • Hosting 46.7.4.1 At CLEC’s request, SBC-SWBT and SBC-AMERITECH shall perform hosting responsibilities for the provision of billable message data and/or access usage data received from CLEC for distribution to the appropriate billing and/or processing location or for delivery to CLEC of such data via SBC-SWBT’s and SBC-AMERITECH’s internal network or the nationwide CMDS network pursuant to the applicable Appendix HOST, which is/are attached hereto and incorporated herein by reference.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Operations Support Systems Verizon systems for pre-ordering, ordering, provisioning, maintenance and repair, and billing.

  • Software Development Software designs, prototypes, and all documentation for the final designs developed under this agreement must be made fully transferable upon direction of NSF. NSF may make the software design, prototype, and documentation for the final design available to competitors for review during any anticipated re-competition of the project.

Time is Money Join Law Insider Premium to draft better contracts faster.