SFA Phasing Plan Implementation. Jacobs’ original mechanical system design was based upon the understanding that the campus chilled water piping would be installed and operational in conjunction with the CUP project, and that construction of the CUP would be prioritized over the renovations of the SFA chiller plant. As such it was anticipated that the plant and distribution system would be tested and brought online at the same time to support service to the new and existing buildings. Based on changes to the overall construction schedule for the other projects, it will become necessary to continue the use of the temporary chilled water piping truss bridging across Congress Street in conjunction with operation of the CUP and renovated SFA plant. Construction of the SFA plant renovations was prioritized as well. The interim mode of operation proposed by the contractor directly connects the three existing buildings to the distribution system, deferring the installation of the decoupling heat exchangers. As such, Jacobs was requested to review the operational phasing plan proposed by the contractor to determine operability and evaluate the hydraulic and hydrostatic impacts for this interim mode of operation (use of the temporary pipe truss). Jacobs developed a hydraulic model to evaluate flowrates and allowable system pressures for acceptability and DocuSign Envelope ID: 42DC06DB-C071-44AC-A530-2F1BCDA88F15 Texas Facilities Commission Capitol Complex Package 3 – CUP and Tunnel Additional Services Proposal 2 July 29, 2020 determine the acceptability of the distribution pumps to accommodate the interim mode of operation. This plan was contingent on utilizing Grundfos pumps in lieu of Xxxxxxxxx pumps in SFA and, as a result, changed the selection in the CUP as well. Jacobs analyzed and is making made modifications to the CUP piping and support scheme, and Structural will modify the auxiliary steel to account for this change. The mechanical evaluation of the contractor proposed phasing plan is documented for record purposes, but no additional compensation is requested for the mechanical work described herein. Another consequence of the proposed phasing plan requires larger (higher horsepower) pumps in order to overcome the pressure restrictions associated with the use of the temporary piping bridge. Jacobs will evaluate and confirm a design upgrade that accommodates the temporary and permanent electrical service for the larger SFA distribution pumps. Findings from the assessment of the proposed c...
AutoNDA by SimpleDocs

Related to SFA Phasing Plan Implementation

  • Project Implementation 2. The Borrower shall:

  • Implementation Program 1. The Borrower shall:

  • Project Implementation Manual The Recipient, through the PCU, shall: (i) take all action required to carry out Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4 (ii) of the Project in accordance with the provisions and requirements set forth or referred to in the Project Implementation Manual; (ii) submit recommendations to the Association for its consideration for changes and updates of the Project Implementation Manual as they may become necessary or advisable during Project implementation in order to achieve the objective of Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4(ii) of the Project; and (iii) not assign, amend, abrogate or waive the Project Implementation Manual or any of its provisions without the Association’s prior agreement. Notwithstanding the foregoing, if any of the provisions of the Project Implementation Manual is inconsistent with the provisions of this Agreement, the provisions of this Agreement shall prevail and govern.

  • Implementation Plan The Authority shall cause to be prepared an Implementation Plan meeting the requirements of Public Utilities Code Section 366.2 and any applicable Public Utilities Commission regulations as soon after the Effective Date as reasonably practicable. The Implementation Plan shall not be filed with the Public Utilities Commission until it is approved by the Board in the manner provided by Section 4.9.

  • Joint Network Implementation and Grooming Process Upon request of either Party, the Parties shall jointly develop an implementation and grooming process (the “Joint Grooming Process” or “Joint Process”) which may define and detail, inter alia:

  • Staffing Plan 8.l The Board and the Association agree that optimum class size is an important aspect of the effective educational program. The Polk County School Staffing Plan shall be constructed each year according to the procedures set forth in Board Policy and, upon adoption, shall become Board Policy.

  • COOPERATION IN IMPLEMENTATION On demand of the other Spouse and without undue delay or expense, each Spouse shall execute, acknowledge, or deliver any instrument, furnish any information, or perform any other acts reasonably necessary to carry out the provisions of this Agreement. If a Spouse fails to execute any document as required by this provision, the court may appoint the court clerk or his or her authorized designee to execute the document on that Xxxxxx’s behalf.

  • Implementation of Strategic Plan Goals This Agreement supports the County’s Strategic Plan, Goal 1, Operational Effectiveness/Fiscal Sustainability. This Agreement will provide revenue reimbursement to the Department for services rendered.

  • Improvement Plan A written plan developed by the evaluator, utilized when a teacher received a Rating of Ineffective on his/her Evaluation or on any individual deficiency in the evaluation system.

  • Performance Improvement Plan timely and accurate completion of key actions due within the reporting period 100 percent The Supplier will design and develop an improvement plan and agree milestones and deliverables with the Authority

Time is Money Join Law Insider Premium to draft better contracts faster.