General Design Parameters Sample Clauses

General Design Parameters. Equipment shall be designed: • To facilitate manufacture, inspection, installation, maintenance, cleaning and repairs. • To ensure safe and satisfactory operation for an acceptable life expectation of 12 years under the ambient conditions prevailing at the Site. • To prevent undue stresses being produced by expansion due to temperature changes. • To keep maintenance costs to a minimum. • To facilitate inter-changeability of units and/or sub-parts throughout the Contract works with regard to new equipment and equipment and/or sub-parts currently being used on the existing JW Wastewater Treatment Works. • To operate without undue vibration and excessive noise. Maximum of 84dBA measured at 1 metre from operating equipment. • To comply with the legal requirements in respect of safety as well as the prevention of water and air pollution. • To satisfy any specific requirement contained in the statutory codes and legislation. • To be suitable for operation 365 days per year, 24 hours per day under specified design conditions.
AutoNDA by SimpleDocs
General Design Parameters. Waste Sludge Thickener Tanks shall be designed such that the following requirements are met:- • To facilitate manufacture, inspection, installation, maintenance, cleaning and repairs, • To ensure safe and satisfactory operation for an acceptable life expectation of 12 years under the ambient conditions prevailing at the Site, • To prevent undue stresses being produced by expansion due to temperature changes. • To keep maintenance costs to a minimum, • To comply with the legal requirements in respect of safety as well as the prevention of water and air pollution, • To satisfy any specific requirement contained in the statutory codes and legislation, and • To be suitable for operation 365 days per year, 24 hours per day under specified design conditions.
General Design Parameters. The following criteria shall apply to the design and planning of the Project by SCC:

Related to General Design Parameters

  • Final Design Phase A. After acceptance by Owner of the Preliminary Design Phase documents, revised opinion of probable Construction Cost as determined in the Preliminary Design Phase, and/or any other Right of Way plan documents, subject to any Owner-directed modifications or changes in the scope, extent, character, or design requirements of or for the Project, and upon written authorization from Owner, Engineer shall:

  • Design Standards Most recent edition of the “Owner’s Design Standards,” including any partial updates as may be directed by the Owner.

  • Schematic Design Phase INDICATE IN STATEMENT OF WORK “NOT APPLICABLE” IF SECTION IS NOT APPLICABLE

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • Design Criteria and Standards All PROJECTS/SERVICES shall be performed in accordance with instructions, criteria and standards set forth by the DIRECTOR.

  • Design Services The Engineer shall perform services during the schematic design phase, the design development phase, the contract documents phase, and the bidding period as hereinafter specified.

  • Design Phase All Basic Services set forth in the Agreement with the exception of Interdisciplinary Document Coordination Review, conducting a Card Trick session, Value-Engineering services, Estimating services. Bidding Phase • All Basic Services set forth in the Agreement. Construction Phase • All Basic Services set forth in the Agreement. Post-Construction • All Basic Services set forth in the Agreement.

  • Preliminary Design Phase During the Preliminary Design Phase, the CONSULTANT shall, if requested by the CITY and accepted by the CONSULTANT as part of a Services Authorization:

  • Project Implementation Manual The Recipient, through the PCU, shall: (i) take all action required to carry out Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4 (ii) of the Project in accordance with the provisions and requirements set forth or referred to in the Project Implementation Manual; (ii) submit recommendations to the Association for its consideration for changes and updates of the Project Implementation Manual as they may become necessary or advisable during Project implementation in order to achieve the objective of Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4(ii) of the Project; and (iii) not assign, amend, abrogate or waive the Project Implementation Manual or any of its provisions without the Association’s prior agreement. Notwithstanding the foregoing, if any of the provisions of the Project Implementation Manual is inconsistent with the provisions of this Agreement, the provisions of this Agreement shall prevail and govern.

  • Schematic Design Documents In accordance with the approved Preliminary Design and Construction Schedule and based upon approval of and comments made by the Owner regarding the Concept Design Studies, the Design Professional shall prepare and submit to the Owner Schematic Design Documents, including drawings and outline specifications. These documents shall represent a further development of the approved design concept, providing additional detail and specificity regarding the intended design solution. Typically, all such documents shall be drawn to scale, indicating materials and assemblies, as appropriate, to convey the design intent and to illustrate the Project’s basic elements, scale and relationship to the Site. All major pieces of furniture and equipment to be fixed or supplied by the CM/GC shall be illustrated to scale. (See ASTM Standard Practice E 1804-02, August 2007, Sections 6.3, 8.2 and 8.3 for guidance on information which is generally developed in Schematic Design.)

Time is Money Join Law Insider Premium to draft better contracts faster.