Humidity test Sample Clauses

Humidity test. After being laminated to glass and scored, the product shall show no evidence of deterioration following a 48 hour exposure to a relative humidity of 98% at 50 degrees centigrade.
AutoNDA by SimpleDocs
Humidity test. Expose the CK, in both operational mode and transportation mode, to the test conditions for the aggravated temperature-humidity cycle in accordance with test method standard MIL-STD-810, Humidity test, Method 507.4, both the operational mode and transportation mode will be exposed for 5 cycles. After each mode of cycling has been W911QY-04-R-0011 Attachment 1 MIL-PRF-32026(GL) completed, inspect the CK for evidence of corrosion, structural damage, degradation, or permanent deformation.
Humidity test. The product shall show no evidence of deterioration after being subjected for 48 hrs to a temperature of 48.9 (plus/minus) 2.2(degrees)C and a relative humidity of 98 (plus/minus) 2%. Refer to 3.3.6 for sample preparation.
Humidity test. Humidity test is conducted on two randomly selected as anodized witness coupons. The test results should confirm the requirements specified in process qualification test. Thermal cycling test: Thermal cycling test is conducted on two randomly selected as anodized witness coupons. However, for acceptance test coupons are subjected to only 100 hot and cold cycles as specified in qualification test. The test coupons should pass through the test conducted without any degradation. Measurement of optical properties: The optical properties, infrared emittance of the coating are measured wherever feasible on some of the selected areas of components and the test coupons before and after environmental tests (humidity and thermal cycling). The optical properties should confirm the requirements as specified under technical specifications and no change in infrared emittance should be observed after environmental tests. ANNEXURE 2 CHECKLIST/GENERAL SPECIFICATIONS FOR ELIGIBILITY FOR QUALIFICATION BY ISAC ELIGIBILTY CRITERIA Sl. No. Description Compliance Remarks A minimum of 5 years of experience in carrying out Anodizing, Black Anodizing & Hard Anodizing on Aerospace components made out of Aluminum 6061 alloys ISRO Qualification/ NADCAP certification to process Aerospace components Dedicated process line (As per Annexure 3) established in ~1500 ft2 area (minimum) to carry out Anodizing, Black Anodizing & Hard Anodizing on Aerospace components made out of Aluminum 6061 alloys ISO 9001-2008/AS9100 certificate Clearance from Karnataka Pollution Control Board to carry out electroplating activities Effluent treatment Facility Chemical Analysis facility with qualified personnel Safety practice (As per Annexure 4) To provide the Bank Guarantee for the value of FIM issued against each work order. DEDICATED PROCESS LINE DETAILS
Humidity test. Humidity test is conducted on two randomly selected as anodized witness coupons. The test results should confirm the requirements specified in process qualification test.
Humidity test. The humidity test is carried out to examine the resistance of anodic film to corrosive pre-launch and launch atmosphere. The test is conducted in a thermostatically controlled humidity chamber. The relative humidity in the chamber is maintained with 95 ± 0.5% at 50oC. After the test the anodic coating is examined visually and their optical properties are measured. No degradation in physical appearance and optical properties should be observed.

Related to Humidity test

  • Temperature Where low temperature and/or self-service cases are used for any of such merchandise coming under the jurisdiction of the Union, such cases shall be served only by employees covered by this Agreement.

  • Stability Testing Patheon may be requested to conduct stability testing on the Products in accordance with the protocols set out in the Specifications for the separate fees and during the time periods set out in Schedule C to a Product Agreement. Patheon will not make any changes to these testing protocols without prior written approval from Client. If a confirmed stability test failure occurs, Patheon will notify Client within one Business Day, after which Patheon and Client will jointly determine the proceedings and methods to be undertaken to investigate the cause of the failure, including which party will bear the cost of the investigation. Patheon will not be liable for these costs unless it has failed to perform the Manufacturing Services in accordance with the Specifications, cGMPs, and Applicable Laws. Patheon will give Client ail stability test data and results at Client’s request.

  • Laboratory Testing All laboratories selected by UPS Freight for analyzing Controlled Substances Testing will be HHS certified.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Acceptance Test 7.1 Before delivering the Goods or Articles upon completion of the Services, the Seller shall carefully inspect and test them for compliance with the Specification. The Seller shall, if required by the Buyer, give the Buyer reasonable notice of such test and the Buyer shall be entitled to be represented thereat. The test shall hereinafter be referred to as the “Acceptance Test”.

  • Maintenance Period During the Maintenance Period the Developer shall at its own expense maintain repair and otherwise S.9 keep the Works in good working order and repair to the reasonable satisfaction of xxx Xxxxxxxxxx unless xxx Xxxxxxxxxx shall declare that any required maintenance and/or repair is an emergency in which case the Developer shall carry out the said maintenance and/or repair immediately Access to the Works and consequences of inspections The Developer shall arrange for xxx Xxxxxxxxxx to have access to the Works and the Site at all

  • Measuring EPP parameters Every 5 minutes, EPP probes will select one “IP address” of the EPP servers of the TLD being monitored and make an “EPP test”; every time they should alternate between the 3 different types of commands and between the commands inside each category. If an “EPP test” result is undefined/unanswered, the EPP service will be considered as unavailable from that probe until it is time to make a new test.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Reformulation Standard “Reformulated Products” shall mean Products that contain concentrations less than or equal to 0.1% (1,000 parts per million (ppm)) of DEHP when analyzed pursuant to U.S. Environmental Protection Agency testing methodologies 3580A and 8270C or other methodology utilized by federal or state government agencies for the purpose of determining the phthalate content in a solid substance.