FUEL OIL PUMPS Sample Clauses

FUEL OIL PUMPS. The Contractor shall provide and install a fuel oil transfer pump as shown on the contract drawings to transfer fuel from the port and starboard fuel oil storage tanks off-vessel at the forward and midship fueling lockers. A bronze simplex basket strainer shall be installed before the inlet of the pump. The pump shall be coupled to an AC electric motor and shall be furnished as a matched set from the pump manufacturer. See contract Clause C750 for additional requirements on drives and motors. The pump shall be provided with local controls near the pump and remotely inside each of the fueling lockers. The controls shall have start, stop and a run indicator light. The controls inside the fueling lockers shall be rated for Class 1, Division 1 applications. An emergency pump stop control, in a weather tight enclosure, shall be installed on the main deck exterior near the switchboard room. The Contractor shall provide and install two (2) fuel oil transfer pumps as shown on the contract drawings to transfer fuel from the port and starboard fuel oil storage tanks to the fuel oil day tank in order to serve the diesel generator sets. A bronze simplex basket strainer shall be installed before the inlet of the pump. Each pump shall be coupled to an AC electric motor and shall be furnished as a matched set from the pump manufacturer. See contract Clause C750 for additional requirements on drives and motors. One pump shall be provided with hand/off/ automatic modes of operation, and the other pump shall be manual control only. Manual controls shall be provided locally near the pump and remotely near the day tank in the switchboard room. The controls shall have start, stop and a run indicator light. Automatic control of the pump shall be provided based on input from the fuel oil day tank level sensors. The pumps shall be configured to turn on when the level in the fuel oil day tank reaches 20 percent and shall turn off when the level reaches 85 percent. An emergency pump stop control, in a weather tight enclosure, shall be installed on the main deck exterior near switchboard room.
AutoNDA by SimpleDocs

Related to FUEL OIL PUMPS

  • Fuel 28.1 The Vehicle must be returned with the amount of fuel equal to that at the time of the commencement of the rental. If the Vehicle is returned with less fuel, the difference will be charged to You at a rate of $5.00 including GST per litre (which includes a service component).

  • Delivery Point (a) All Energy shall be Delivered hereunder by Seller to Buyer at the Delivery Point. Seller shall be responsible for the costs of delivering its Energy to the Delivery Point consistent with all standards and requirements set forth by the FERC, ISO-NE, the Interconnecting Utility and any other applicable Governmental Entity and any applicable tariff.

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • Delivery Points ‌ Project water made available to the Agency pursuant to Article 6 shall be delivered to the Agency by the State at the delivery structures established in accordance with Article 10.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties have agreed to use One-Way Interconnection Trunks for the delivery of traffic from PCS to Verizon, PCS, at PCS’s own expense, shall:

  • Interconnection Customer Interconnection Facilities Interconnection Customer shall design, procure, construct, install, own and/or control Interconnection Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.

  • By Interconnection Customer Interconnection Customer may unilaterally terminate the Interconnection Service Agreement pursuant to Applicable Laws and Regulations upon providing Transmission Provider and the Interconnected Transmission Owner sixty (60) days prior written notice thereof, provided that Interconnection Customer is not then in Default under the Interconnection Service Agreement.

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • Interconnection Point The Service Provider is responsible for connecting to the LFC Network at the Interconnection Point. The LFC may only change an Interconnection Point if a change is necessary to protect the security or integrity of that Interconnection Point in order to maintain the continuity of supply of the Wholesale Services. In the event of any such change:

Time is Money Join Law Insider Premium to draft better contracts faster.