XLOAD Sample Clauses

XLOAD. EXE is a PC-DOS program and has the following command line syntax: XLOAD -c<CODE> -f<CONFIG> where: CODE is the name of the file containing the SDLA executable code for the HDLC implementation, e.g. HDLC.502. CONFIG is the name of the file containing the HDLC configuration information, e.g. HDLC.SDL Example: XLOAD -c\HDLC\HDLC.502 -f\HDLC\HDLC.SDL XLOAD will perform a system test, read the CODE and CONFIG files and load and configure the adapter. If XLOAD does not execute successfully, an error message will be displayed and an exit code will be returned. XLOAD may also display configuration warning messages. A description of these messages and corresponding exit codes are described in Section "Error Messages". HDLC.502 This is the HDLC support code which is loaded onto the card and establishes the link level communications. HDLC.502 is NOT a PC-DOS program and is not executable under DOS. HDLC.SDL This file contains the HDLC code configuration data. HDLC.SDL is an ASCII text file and may be edited using any standard editor. The default parameters are as follows: io_port = 0x360 mem_segment = 0xC000 mem_window = 8 line_speed = 9600 DTE = 1 line_speed Value PC memory window 0 0000H to 1FFFH 2 2000H to 3FFFH 4 4000H to 5FFFH 6 6000H to 7FFFH 8 8000H to 9FFFH A A000H to BFFFH C C000H to DFFFH T1 = 1 T2 = 0 T4 = 10 N2 = 10 k = 7 auto_modem_err_fixup = 1 auto_HDLC = 1 HDLC_config_options = 0x00 The HDLC link normally takes the line clocking from the modem. However, the S502 adapter will provide a clocking signal on pin 24. This means that in a local attach or test situation, there is no need for the expense or complexity of a modem eliminator. Valid values are (7.2 MHz adapter): Value (bps) Actual Line Comments Speed (bps) max_I_f ie l d _l en g t h = 1027 0 ---- No clocking signal provided io_port 1200 1202 This corresponds to the base port address as set by the jumpers 2400 2405 on the SDLA adapter. Valid values are 0x250, 0x300, 0x350 4800 4760 and 0x360. 9600 9727 19200 18643 38400 37286 mem_segment 45000 44744 This is the 64K PC memory segment in which the shared 56000 55930 memory window will reside. Valid values are 0xA000, 0xC000, 64000 55930 0xD000 and 0xE000. 74447 74573 112000 111860 128000 111860 mem_window This defines the 8k window of the PC memory segment which the PC sees as being occupied by the SDLA card. Valid values DTE and their meanings are as follows: Defines the station's link level and packet level configuration and should be set to 1 fo...
AutoNDA by SimpleDocs
XLOAD. EXE XLOAD.EXE is a PC-DOS program and has the following command line syntax: XLOAD -c<CODE> -f<CONFIG> where: CODE is the name of the file containing the SDLA executable code for the X.25 implementation, e.g. X25.502. CONFIG is the name of the file containing the X.25 and HDLC configuration information, e.g. X25.SDL Example: XLOAD -c\X25\X25.502 -f\X25\X25.SDL XLOAD will perform a system test, read the CODE and CONFIG files and load and configure the adapter. If XLOAD does not execute successfully, an error message will be displayed and an exit code will be returned. XLOAD may also display configuration warning messages. A description of these messages and corresponding exit codes are described in Section "Error Messages".

Related to XLOAD

  • DELIVERY PRESSURE Xxxxxx agrees to use due care and diligence to furnish gas hereunder at such uniform pressure as Seller may elect up to, but not exceeding 20 pounds per square inch gauge, and not less than 5 pounds per square inch gauge, at the "Point of Delivery". Buyer shall be responsible for the installation and operation of adequate safety equipment downstream of the Point of Delivery so as to relieve or control pressure variations within the limits described above that may, for any reason through malfunction of Seller's equipment or otherwise, occur on Buyer's side of the "Delivery Point".

  • Work Load The professional obligation of academic employees comprises both scheduled and non-scheduled activities. The Guild and the District recognize that it is part of the professional responsibility of faculty to carry out their duties in an appropriate manner and place. As part of this responsibility faculty are expected to play an important role in the recruitment and retention of students, campus and departmental governance, program review, accreditation, planning and mentoring. Faculty commitment to retention will be demonstrated by informing students that they are to talk with the instructor prior to dropping the course. Faculty are encouraged to include a statement to this effect in their course syllabi. While it is understood that course syllabi content falls within the purview of the individual faculty member’s academic freedom, the parties also understand that items required to be part of syllabi in order to maintain college or continuing education accreditation must also be included. Tenured/tenure-track faculty who have less than a full-time contract are not eligible to work any additional assignments including long-term substitution (day-to-day substitution is allowed provided the limits specified in Section 5.2.1.3 are not exceeded). Faculty assignments shall be made in the following priority order: Tenured/tenure-track, pro- rata, overload, Priority of Assignment (POA) adjunct faculty assignments, then non-POA adjunct faculty.

  • Bandwidth the amount of data (quantified as “Mbps” or “Gbps”) made available to Customer as specified in a Service Order.

  • Floor Load Tenant shall not place a load upon any floor of the Premises that exceeds 50 pounds per square foot “live load”. Landlord reserves the right to reasonably designate the position of all Equipment which Tenant wishes to place within the Premises, and to place limitations on the weight thereof.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Network Upgrades The Transmission Owner shall design, procure, construct, install, and own the Network Upgrades described in Attachment 6 of this Agreement. If the Transmission Owner and the Interconnection Customer agree, the Interconnection Customer may construct Network Upgrades that are located on land owned by the Interconnection Customer. Unless the Transmission Owner elects to pay for Network Upgrades, the actual cost of the Network Upgrades, including overheads, shall be borne initially by the Interconnection Customer.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Workload An employee who believes that her workload is unsafe or consistently excessive shall discuss the problem with her immediate supervisor. If the problem is not resolved in this discussion, the employee may seek a remedy by means of the grievance procedure. If the matter is not resolved in the grievance procedure, it may be referred to troubleshooter who shall:

  • Flextime (a) For the purpose of this Agreement, flextime means the hours worked by an employee, or group of employees, who are given authority by the Employer to:

  • Generators Temporary installation of generators, and permanent installation of generators that are placed inside existing non-residential buildings or that occupy an area under 50 square feet behind the building they serve.

Time is Money Join Law Insider Premium to draft better contracts faster.