eFiling Direct Connector Sample Clauses

eFiling Direct Connector. The eFiling Direct Connector must be a XML based, secured, access controlled web service that will allow EFSPs to submit filings to the EFM and to manage filer user accounts. The eFiling Direct Connector must employ security so that the transmissions are encrypted and initiated from known sources. Upon a successful submission, the eFiling Direct Connector must provide a success code and a confirmation number back to the EFSP. The eFiling Direct Connector must then insert the filing and metadata into the EFM for further processing by the clerk’s office. If the filing is unsuccessful, the eFiling Direct Connector must return an error code that can be deciphered by the EFSP for further action by the filer. The eFiling Direct Connector must provide standard interface messaging in order for the EFSPs to determine the current status of submitted filings. The system must provide back to the EFSPs the following information: • unique trace number of the filing • the outcome of the filing (accepted, rejected or error) • the date/time the outcome was determined • access to the file-stamped copy of the document The web services must be implemented in compliance with the Electronic Case File 4.0 standard and any future revisions. Tyler shall support the following services: • FilingAssembly – submits the assembled filing document(s) and metadata and makes them available for court review • GetPolicy – retrieves the policy information of a specific court in an XML format • GetFeesCalculation – retrieves the fees applicable for the given filing • GetFilingList – retrieves the list of filings that match the given parameters (filer, case, or date range) • GetFilingStatus – retrieves the current status of a filing Tyler shall provide the following identification management web services: • Authenticate a user by user name and passwordRegister a new user account • Deactivate a user account • Update the email address on the account • Retrieve the security question for a user by user name (to support password reset) • Reset the password of a user by user name, given the matching response to the security question Tyler must provide to EFSPs the service interface documentation to the eFiling Direct Connector web services.
AutoNDA by SimpleDocs

Related to eFiling Direct Connector

  • Signaling protocol The Parties will interconnect their networks using SS7 signaling where Technically Feasible and available as defined in GR 905 Telcordia Standards including ISDN User Part (ISUP) for trunk signaling and TCAP for CCS-based features in the Interconnection of their networks. All Network Operations Forum (NOF) adopted standards shall be adhered to. Where available, CenturyLink signaling services to link its Signaling Transfer Points (STPs) for CLEC switches which connect to CenturyLink’s STPs via “A” links or for CLEC’s STPs to connect to CenturyLink’s STPs via “D” links which are dedicated to the transport of signaling for local Interconnection, may be ordered from the CenturyLink Tariff.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where EveryCall has requested an Unbundled Loop and BellSouth uses Integrated Digital Loop Carrier (IDLC) systems to provide the local service to the end user and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to EveryCall. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for EveryCall (e.g. hairpinning):

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Library CONTRACTOR shall provide an inmate law library in compliance with Rule 33-501.301, F.A.C., FDC’s Policy 501.301, and ACA Standards.

  • Local Switching Interfaces 4.2.13.1 Deland Actel shall order ports and associated interfaces compatible with the services it wishes to provide as listed in Exhibit A. BellSouth shall provide the following local switching interfaces:

  • Searchability Offering searchability capabilities on the Directory Services is optional but if offered by the Registry Operator it shall comply with the specification described in this section.

  • Interface A defined set of transmission facilities that separate Load Zones and that separate the NYCA from adjacent Control Areas. Investor-Owned Transmission Owners. A Transmission Owner that is owned by private investors. At the present time these include: Central Xxxxxx Gas & Electric Corporation, Consolidated Edison Company of New York, Inc., New York State Electric & Gas Corporation, Niagara Mohawk Power Corporation, Orange and Rockland Utilities, Inc., and Rochester Gas and Electric Corporation.

  • Background Screening VENDOR shall comply with all requirements of Sections 1012.32 and 1012.465, Florida Statutes, and all of its personnel who (1) are to be permitted access to school grounds when students are present, (2) will have direct contact with students, or (3) have access or control of school funds, will successfully complete the background screening required by the referenced statutes and meet the standards established by the statutes. This background screening will be conducted by SBBC in advance of VENDOR or its personnel providing any services under the conditions described in the previous sentence. VENDOR shall bear the cost of acquiring the background screening required by Section 1012.32, Florida Statutes, and any fee imposed by the Florida Department of Law Enforcement to maintain the fingerprints provided with respect to VENDOR and its personnel. The parties agree that the failure of VENDOR to perform any of the duties described in this section shall constitute a material breach of this Agreement entitling SBBC to terminate immediately with no further responsibilities or duties to perform under this Agreement. VENDOR agrees to indemnify and hold harmless SBBC, its officers and employees from any liability in the form of physical or mental injury, death or property damage resulting from VENDOR’s failure to comply with the requirements of this section or with Sections 1012.32 and 1012.465, Florida Statutes.

Time is Money Join Law Insider Premium to draft better contracts faster.