Steel Staircase Sample Clauses

Steel Staircase. TS-746 All Steel works should be done by Certified Welder TS-747 All Steel sections should be Black Steel of Grade S275 TS-748 All Steel should be Galvanize in a Hot Dipp with coverage not less than indicated by ASTM A123 TS-749 All Checkered plates Should be of grade Q235 TS-750 All Checkered plates Should be of grade Q235 TS-751 Galvanizing should be after fabrication TS-752 All Bolts to be of Grade (8.8) structural for all sizes TS-753 Tightining Tourque for Bolts should be as follows TS-754 M 16 8.8 not less than 70 NM TS-755 M 14 8.8 not less than 45 NM TS-756 M 12 8.8 not less than 30 NM TS-757 Welding rods Xxxx 7018 TS-758 Welding on site is not allowed accept approved by site Engineer TS-759 All STeps Re made of shaped (bent) 8mm heckered plates as per drawings TS-760 All works should submitted for approval through shopdrawings TS-761 Quantites to be measured by weight for all parts of the structure excluding bolts and welds TS-762 Bolts and Welds are included in the price TS-763 Arc Welding tests ( UltraSonic non destructive test) TS-764 Bolts Tourque test included in the price TS-765 Cranes for installation and transportion is included in the price TS-766 This Specification deals with the installation of the materials, fittings and equipment, the design and performance, the workmanship and the testing and commissioning of the below ground drainage. TS-767 This Specification is in addition to and will be read in conjunction with the Contract Drawings and relevant parts of the Contract Documents.
AutoNDA by SimpleDocs

Related to Steel Staircase

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Construction Management Landlord or its Affiliate or agent shall supervise the Work, make disbursements required to be made to the contractor, and act as a liaison between the contractor and Tenant and coordinate the relationship between the Work, the Building and the Building’s Systems. In consideration for Landlord’s construction supervision services, Tenant shall pay to Landlord a construction supervision fee equal to three percent (3%) of Tenant’s Costs specified in Section 7.

  • Construction Phase Services 3.1.1 – Basic Construction Services

  • Building Access i. Access to Secured buildings: Contractor will work through the GIT Contract administrator for access to the building.

  • Power System Stabilizers The Developer shall procure, install, maintain and operate Power System Stabilizers in accordance with the requirements identified in the Interconnection Studies conducted for Developer’s Large Generating Facility. NYISO and Connecting Transmission Owner reserve the right to reasonably establish minimum acceptable settings for any installed Power System Stabilizers, subject to the design and operating limitations of the Large Generating Facility. If the Large Generating Facility’s Power System Stabilizers are removed from service or not capable of automatic operation, the Developer shall immediately notify the Connecting Transmission Owner and NYISO. The requirements of this paragraph shall not apply to wind generators.

  • Architect/Engineer (A/E) means a person registered as an architect pursuant to Tex. Occ. Code Xxx., Chapter 1051, as a landscape architect pursuant to Tex. Occ. Code Xxx., Chapter 1052, a person licensed as a professional engineer pursuant to Tex. Occ. Code Xxx., Chapter 1001 and/or a firm employed by Owner or a design-build contractor to provide professional architectural or engineering services and to exercise overall responsibility for the design of a Project or a significant portion thereof, and to perform the contract administration responsibilities set forth in the Contract.

Time is Money Join Law Insider Premium to draft better contracts faster.