Specific Schedule of maintenance routines Sample Clauses

Specific Schedule of maintenance routines. CCTV No . Code Description Service description Frequency Remarks on Compliance Cameras C1 Camera External • Visual inspect, check weatherproof gasket for seal, rectify where necessary. • Check internal of housing for moisture rectify where necessary. • Check external joints, glands, make off and re-seal where necessary • Clean housing glass. Replace where necessary. 6months C2 Pan Tilt Mechanism • Check operation of pan tilt mechanism Reset limits where necessary. • Check gearbox, bearings, etc. Adjust or replace where necessary • Check pan tilt controller for ingress of moisture. Replace seal where necessary • Check pan tilt operation. Re-set to manufacturer's specification. Replace electronics where necessary 3 months C3 Camera Bracket Check bracket mounts/poles for corrosion or Mounts/Poles failure and damage to paint Rub down, repaint or replace where necessary Check operation of access door locks, lubricate as necessary Check securing of fixings and fastenings tighten/adjust as necessary 3 months C4 Camera Lens • Remove optical lens. Inspect for moisture seal failure. Rectify or replace where necessary • Clean optical lens with proprietary soft lens cloth and refit. • Check operation of iris and zoom. 3 months • Adjust where necessary C5 Camera Performance • Measure and record camera's performance. • Provide hard /soft copy of waveform trace 3 months C6 Telemetry Unit(where applicable) • Check all functions operate correctly • Recalibrate where necessary • Check video loop through • Check video loop through • Check data stream • Check button operation • Check BNC or other connections • Rectify or replace where necessary. 3 months C7 Cables and ducting • Check cable protection ducts, conduits, mini-trucking etc to ensure proper physical conditions. • Check all cables for damage, continuity, etc. Replace where necessary 3 months C8 Connections Check all connections, plugs for damage continuity, moisture ingress Check BNC,RG 45 and other connectors. Replace where necessary 3 months D1 DVR /NVR performance/fun ctionality • Check all functions operate correctly(Recording, time, playbacks, Event logs,voltages,resolution,softwar e,drives,streaming,network,data base,etc • Check all control functions • Reconfigure to right performance specifications/factory resets where necessary. 3 months D2 DVR/NVR /Video Encoder Storage and recording status • Check and service recording drives and hardisks • Check capacity and advice or rectify storage capacity issues. 3 mo...
AutoNDA by SimpleDocs

Related to Specific Schedule of maintenance routines

  • Maintenance Scheduling The NTO shall schedule maintenance of its facilities designated as NTO Transmission Facilities Under ISO Operational Control and schedule any outages (other than forced transmission outages) of said transmission system facilities in accordance with outage schedules approved by the ISO. The NTO shall comply with maintenance schedules coordinated by the ISO, pursuant to this Agreement, for NTO Transmission Facilities Under ISO Operational Control. The NTO shall be responsible for providing notification of maintenance schedules to the ISO for NTO Transmission Facilities Requiring ISO Notification. The NTO shall provide notification of maintenance schedules to affected Transmission Owners for NTO Transmission Facilities Requiring ISO Notification and Local Area Transmission Facilities pursuant to Section 3.5.3 of the ISO Services Tariff.

  • Records Maintenance; Access Contractor shall maintain all financial records relating to this Contract in accordance with generally accepted accounting principles. In addition, Contractor shall maintain any other records, books, documents, papers, plans, records of shipments and payments and writings of Contractor, whether in paper, electronic or other form, that are pertinent to this Contract (“Records”) in such a manner as to clearly document Contractor's performance. Contractor acknowledges and agrees that Agency and the Oregon Secretary of State's Office and the federal government and their duly authorized representatives will have access to such financial records and other Records that are pertinent to this Contract, whether in paper, electronic or other form, to perform examinations and audits and make excerpts and transcripts. Contractor shall retain and keep accessible all such financial records and other Records for a minimum of 6 years, or such longer period as may be required by applicable law, following final payment and termination of this Contract, or until the conclusion of any audit, controversy or litigation arising out of or related to this Contract, whichever date is later.

  • Schematic Design Phase Services § 3.2.1 The Architect shall review the program and other information furnished by the Owner, and shall review laws, codes, and regulations applicable to the Architect’s services.

  • Operation and Maintenance Manuals Receipts for transmittal of Operation and Maintenance Manuals, Brochures and Data to the Design Professional (or Commissioning Agent) as required by Section 6.1.1.5.

  • Solicitations for Subcontracts, Including Procurements of Materials and Equipment In all solicitations either by competitive bidding or negotiation made by the Engineer for work to be performed under a subcontract, including procurements of materials or leases of equipment, each potential subcontractor or supplier shall be notified by the Engineer of the Engineer's obligations under this contract and the Regulations relative to nondiscrimination on the grounds of race, color, or national origin.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Planned Maintenance (a) Sellers may designate up to twenty (20) Days of Planned Maintenance on Sellers’ Facilities during each Contract Year. Sellers shall be entitled to reduce (including down to zero (0)) its Gas scheduling under Clause 8 and Exhibit 3 for each Day of Planned Maintenance.

Time is Money Join Law Insider Premium to draft better contracts faster.