Electrical Connections, Surge Protectors and Telephone Lines Sample Clauses

Electrical Connections, Surge Protectors and Telephone Lines. All purchased and leased machines should come equipped with an external surge protector to protect their telephone, network, and electronic components, in addition to any internal surge protector. Surge protectors must come with a minimum five (5) year manufacturer’s warranty stating the surge protector will be replaced free of charge if it fails and the manufacturer will repair or replace any machine damaged by power surges when properly connected to the surge protector. All awards must include external surge suppression/power filter equipment at no additional charge and must meet the following minimum specifications. • Fax/Modem Protection – o In/Out RJ11 modular jacks. o FCC registration numbers must be marked on each unit. o Must contain automatic resettable fuse in protection circuit. o Must incorporate a wideband filter to block DSL signal interference. • Network Protection – o In/Out RJ45 modular jacks. o ETL Verified to TIA/EIA-568-B.2 Cat5e standard. • Frequency Attenuation - o Normal mode: 30 dB min, 45 kHz - 23 MHz. o Common mode: 30 dB min, 20 kHz - 30 MHz. • Remnant voltage, IEEE C62.41 Cat. B Impulse, neutral-ground: 50 Volt peak max. • UL Suppressed Voltage Rating of 330 volts on all 3 modes. • Unit must operate in continuous mode – no over voltage shut off disconnect. • Polarity Correction – Unit must correct polarity on reverse wired outlets. • Unit must not provide power if wall outlet is not properly grounded or missing ground. • Minimum of 3 AC receptacles, including 1 flexible (“pigtail”) outlet. • UL Listed and marked on each product.
AutoNDA by SimpleDocs
Electrical Connections, Surge Protectors and Telephone Lines. It is recommended that all purchased and leased machines are connected to an external surge protector to protect their telephone, network and electronic components; this is in addition to any internal surge protector. Customers are not required to obtain surge protectors from the equipment vendor as at the time of solicitation surge protectors are available via STC 250-000- 09-1.

Related to Electrical Connections, Surge Protectors and Telephone Lines

  • Availability of Verizon Telecommunications Services 3.1 Verizon will provide a Verizon Telecommunications Service to Reconex for resale pursuant to this Attachment where and to the same extent, but only where and to the same extent, that such Verizon Telecommunications Service is provided to Verizon’s Customers.

  • Electrical connections Equipment requiring electrical connections for operation shall either be hard wired to the Authorized User's provided connections or the Contractor shall be responsible for a male electrical union. All connections shall be made by the Contractor and accomplished in accordance with National Electrical Code requirements. Electrically operated equipment shall be available in the following volts and phases: 208 volt 1 or 3 phase, 60 HZ 220 volt 1 or 3 phase, 60 HZ 440 volt 1 or 3 phase, 60 HZ

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Use of Verizon Telecommunications Services 2.1 Verizon Telecommunications Services may be purchased by Connectel under this Resale Attachment only for the purpose of resale by Connectel as a Telecommunications Carrier. Verizon Telecommunications Services to be purchased by Connectel for other purposes (including, but not limited to, Connectel’s own use) must be purchased by Connectel pursuant to other applicable Attachments to this Agreement (if any), or separate written agreements, including, but not limited to, applicable Verizon Tariffs.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Allocation and use of scarce resources Any procedures for the allocation and use of scarce resources, including frequencies, numbers and rights of way, will be carried out in an objective, timely, transparent and non-discriminatory manner. The current state of allocated frequency bands will be made publicly available, but detailed identification of frequencies allocated for specific government uses is not required.

  • Use of State Facilities Resources and Equipment a. Meeting Space and Facilities. The Employer’s campuses and facilities may be used by the Union to hold meetings subject to the University’s policy and availability of the space. The Employer may provide private space for stewards and/or Union representatives to meet in confidence with those they represent on a space available basis. Staff representatives may reserve and utilize meeting rooms in accordance with University policy and procedure. Such requests will be subject to availability and all applicable fees.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

Time is Money Join Law Insider Premium to draft better contracts faster.