DELIVERY OF ENERGY AND CAPACITY SECTION A SCHEDULING Sample Clauses

DELIVERY OF ENERGY AND CAPACITY SECTION A SCHEDULING. Not later than seven (7) business days prior to the commencement of each calendar Month, Seller shall provide Buyer with a non-binding schedule of proposed deliveries of Energy for each hour of the upcoming Month (the "Monthly Schedule"). Notwithstanding the quantities set forth in a Monthly Schedule, on the business day preceding the day of delivery of such Energy, Seller shall provide Buyer with a final daily schedule for deliveries of Energy no later than the time that is two hours prior to the time that PJM requires submission of final schedules. The volumes set forth in the final daily schedules may vary from each other and from the volumes set forth in Monthly Schedules, provided, that Seller shall schedule for delivery in any calendar year, an amount which equals the Annual Quantity specified in Article II(B) for such calendar year. In the event Seller fails to furnish a final daily schedule or a Monthly Schedule on or before the time specified in the second paragraph of this Article V(A), the scheduled delivery of Energy shall be deemed to be that specified in the Monthly Schedule last delivered by Seller. Any Monthly Schedule or final daily schedule shall be consistent with the requirements of this Article V. Buyer hereby appoints Seller to be and act as its agent to do and perform the scheduling obligations under this Agreement and such other things as may be necessary or convenient thereto. As agent for Buyer for such scheduling obligations, Seller is authorized to act for Buyer for such scheduling obligations, Seller is authorized to act for Buyer in its own name or in the name of Buyer, as deemed necessary or advisable by Seller.
AutoNDA by SimpleDocs

Related to DELIVERY OF ENERGY AND CAPACITY SECTION A SCHEDULING

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5.1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None

  • System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Electrical connections Equipment requiring electrical connections for operation shall either be hard wired to the Authorized User's provided connections or the Contractor shall be responsible for a male electrical union. All connections shall be made by the Contractor and accomplished in accordance with National Electrical Code requirements. Electrically operated equipment shall be available in the following volts and phases: 208 volt 1 or 3 phase, 60 HZ 220 volt 1 or 3 phase, 60 HZ 440 volt 1 or 3 phase, 60 HZ

  • FREQUENCY AND CAPACITY LEVELS No restriction on frequency, capacity and aircraft type.

  • Voltage Schedules Once the Developer has synchronized the Large Generating Facility with the New York State Transmission System, NYISO shall require Developer to operate the Large Generating Facility to produce or absorb reactive power within the design capability of the Large Generating Facility set forth in Article 9.5.1 (Power Factor Design Criteria). NYISO’s voltage schedules shall treat all sources of reactive power in the New York Control Area in an equitable and not unduly discriminatory manner. NYISO shall exercise Reasonable Efforts to provide Developer with such schedules in accordance with NYISO procedures, and may make changes to such schedules as necessary to maintain the reliability of the New York State Transmission System. Developer shall operate the Large Generating Facility to maintain the specified output voltage or power factor at the Point of Interconnection within the design capability of the Large Generating Facility set forth in Article 9.5.1 (Power Factor Design Criteria) as directed by the Connecting Transmission Owner’s System Operator or the NYISO. If Developer is unable to maintain the specified voltage or power factor, it shall promptly notify NYISO.

  • Dispatch and Scheduling 4.3.1 The Power Producer shall be required to schedule its power as per the applicable Regulations / Requirements / Guidelines of CERC / GERC / SLDC / RLDC and maintain compliance to the Grid Code requirements and directions, as specified by SLDC / RLDC from time to time. Any deviation from the schedule will attract the provisions of applicable Regulation / Guidelines / Directions and any financial implication on account of this shall be to the account of the Power Producer.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

Time is Money Join Law Insider Premium to draft better contracts faster.