Corp of Engineers Sample Clauses

Corp of Engineers. (y/n) Highway—state, county, city. (y/n) Railroad. (y/n) Local zoning boards, town boards, etc. (y/n) Joint use permits, if required. (y/n) Notified other pole users of contacts or crossings. ζ Confirm that you have: (y/n) Obtained appropriate franchise(s). (y/n) Obtained pole/anchor easements from land owners. (y/n) Obtained crossing and overhang permits. (y/n) Obtained permit to survey R/W. (y/n) Completed State of Washington Department of Transportation requirements. (y/n) Placed permit number on plans. (y/n) Complied with Kittitas underground facility location requirements. (contact District) _ (y/n) Included sag/tension data on proposed cable. Calculations are based upon the latest edition of the NESC and the latest editions of the requirements of the State of Washington.
AutoNDA by SimpleDocs
Corp of Engineers. (y/n) Highway—state, county, city. (y/n) Railroad. (y/n) Local zoning boards, town boards, etc. (y/n) Joint use permits, if required. (y/n) Notified other pole users of contacts or crossings. ζ Confirm that you have: (y/n) Obtained appropriate franchise(s). (y/n) Obtained pole/anchor easements from land owners. (y/n) Obtained crossing and overhang permits. (y/n) Obtained permit to survey R/W. (y/n) Completed State of Department of Transportation requirements. (y/n) Placed permit number on plans. (y/n) Complied with Underground Facility Location requirements. (y/n) Included sag/tension data on proposed cable. Calculations are based upon the latest edition of the NESC and the latest editions of the requirements of the State of . It is Licensee’s responsibility to obtain all necessary permits and provide the Utility with a copy of each.
Corp of Engineers. (y/n) Highway—state, county, city. (y/n) Railroad. (y/n) Local zoning boards, town boards, etc. (y/n) Joint use permits, if required. (y/n) Notified other Pole users of contacts or crossings. • Confirm that you have: (y/n) Obtained appropriate franchise(s). (y/n) Obtained pole/anchor easements from land owners. (y/n) Obtained crossing and overhang permits. (y/n) Obtained permit to survey R/W. (y/n) Completed State of Colorado Department of Transportation requirements. (y/n) Placed permit number on plans. (y/n) Complied with State of Colorado Underground Facility Location requirements. (y/n) Included sag/tension data on proposed cable. Appendix EDistribution Line Minimum Design Review Information and Suggested Worksheet Calculations are based upon the latest edition of the NESC and the latest editions of the requirements of the State of Colorado. It is Licensee’s responsibility to obtain all necessary permits and provide Utility with a copy of each. The engineer for the Permit applicant shall provide for each Pole(s) the following information: • Project ID • Pole number [if Pole tag missing, contact Utility] • Pole class [existing—i.e., 4, 3, 2…] • Pole size [existing—i.e., 35, 40…] • Pole type [Southern Yellow Xxxx, Xxxxxxx Fir…] • Pole fore span [feet] • Pole back span [feet] • Calculated bending moment at ground level [ft–lbs] Existing: • Power phase condition quantity of AWG/MCM CU/AA/ACSR @ feet above ground line • Power neutral condition quantity of AWG/MCM CU/AA/ACSR @ feet above ground line • Power sec condition quantity of AWG/MCM CU/AA/ACSR @ feet above ground line • Telco #1 cables qty of dia @ • CATV #2 cables qty of dia @ • User #3 cables qty of dia @ • User #4 cables qty of dia @ • User #5 cables qty of dia @ • User #6 cables qty of dia @ ft above ground line ft above ground line ft above ground line ft above ground line ft above ground line ft above ground line Appendix E—Distribution Line Minimum Design Review Information and Suggested Worksheet Proposed: • Proposed cables qty of • Proposed cables qty of dia @ dia @ ft above ground line ft above ground line AGL = Above Ground Level The minimum vertical clearance under all loading conditions measured from the proposed cable to ground level on each conductor span shall be stated above. Variations in topography resulting in ground elevation changes shall be considered when stating the minimum vertical clearance within a given span. Calculated pole bending moment at ground level: [ft–lbs] Pole ...

Related to Corp of Engineers

  • Geotechnical Engineer « »« » « » « » « » « »

  • Professional Engineering and Architect’s Services Professional Engineering and Architect’s Services are not permitted to be provided under this Agreement. Texas statutes prohibit the procurement of Professional Engineering and Architect’s Services through a cooperative agreement.

  • Reverse Engineering The Customer must not reverse assemble or reverse compile or directly or indirectly allow or cause a third party to reverse assemble or reverse compile the whole or any part of the software or any products supplied as a part of the Licensed System.

  • Value Engineering The Supplier may prepare, at its own cost, a value engineering proposal at any time during the performance of the contract. The value engineering proposal shall, at a minimum, include the following;

  • Architect/Engineer (A/E) means a person registered as an architect pursuant to Tex. Occ. Code Xxx., Chapter 1051, as a landscape architect pursuant to Tex. Occ. Code Xxx., Chapter 1052, a person licensed as a professional engineer pursuant to Tex. Occ. Code Xxx., Chapter 1001 and/or a firm employed by Owner or a design-build contractor to provide professional architectural or engineering services and to exercise overall responsibility for the design of a Project or a significant portion thereof, and to perform the contract administration responsibilities set forth in the Contract.

  • No Reverse Engineering You may not, and you agree not to or enable others to, copy (except as expressly permitted by this License or by the Usage Rules if they are applicable to you), decompile, reverse engineer, disassemble, attempt to derive the source code of, decrypt, modify, or create derivative works of the Apple Software or any services provided by the Apple Software, or any part thereof (except as and only to the extent any foregoing restriction is prohibited by applicable law or to the extent as may be permitted by the licensing terms governing use of open-sourced components included with the Apple Software).

  • Independent Engineer Contractor shall cooperate with Independent Engineer in the conduct of his or her duties in relation to the Project and the Work, including the duties listed in Attachment CC. No review, approval or disapproval by Independent Engineer shall serve to reduce or limit the liability of Contractor to Owner under this Agreement.

  • Laboratory Services Covered Services include prescribed diagnostic clinical and anatomic pathological laboratory services and materials when authorized by a Member's PCP and HPN’s Managed Care Program.

  • Geotechnical Investigation Perform in accordance with the City Design Manual and other City requirements as designated in writing by the Director.

  • Engineering Forest Service completed survey and design for Specified Roads prior to timber sale advertisement, unless otherwise shown in A8 or Purchaser survey and design are specified in A7. On those roads for which Forest Service completes the design during the contract, the design quantities shall be used as the basis for revising estimated costs stated in the Schedule of Items and adjusting Timber Sale Account. Forest Service engineering shall be completed according to the schedule in A8. Should Forest Service be unable to perform the designated survey and design by the completion date or other agreed to time, upon written agreement, Purchaser shall assume responsibility for such work. In such event, Contracting Officer shall revise:

Time is Money Join Law Insider Premium to draft better contracts faster.