COATING SYSTEM. 1st Coat: Tnemec Series 94-H2O Hydro-Zinc applied at 2.5 to 3.5 dry mils applied to all bare metal. Thin only with approved thinner, Tnemec 41-2, 41-3 or, 41-39 Thinner. Stripe Coat: Tnemec Series FC20HS-1255 Pota-Pox applied by brush and scrubbed into all weld seams. In addition to weld seams, all edges, corners, bolts, rivets, pits shall receive a stripe coat. 2nd Coat: Tnemec Series FC20HS applied at 6.0 to 8.0 dry mils. Thin only with approved thinner, Tnemec 41-4 Thinner. Total dry film thickness shall be a minimum of 8.5 mils per Section 1.05, Paragraph D. For cold weather applications, Series 44-700 Urethane Accelerator may be added to Series 94-H2O.
AutoNDA by SimpleDocs
COATING SYSTEM. 1st Coat: Tnemec Series 94-H2O Hydro-Zinc applied at 2.5 to 3.5 dry mils applied to all bare metal. Thin only with approved thinner, Tnemec 41-2, 41-3 or, 41-39 Thinner. 2nd Coat: Tnemec Series 66HS-Color Hi-Build Epoxoline applied at 3.0 to 5.0 dry mils.; color to be selected by Tnemec. Thin only with approved thinner, Tnemec 41-4 Thinner. 3rd Coat: Tnemec Series 1074U-Color Endura-Sheild II applied at 2.0 to 3.0 dry mils. Thin only with approved thinner, Tnemec 41-42 Thinner for spray, 41-39 for brush or roller. Logo(s): Tnemec Series 700-Color HydroFlon applied at 2.0 to 3.0 dry mils. Thin only with approved thinner, Tnemec 41-6 Thinner for spray, brush or roller. Two coats may be required depending on finish coat color. Total dry film thickness shall be a minimum of 7.5 mils per Section 1.05, Paragraph D. For cold weather applications, Series 44-710 Urethane Accelerator may be added to Series 94-H20 and Series 1074U at the rate specified on the Series 44-710 product data sheet.
COATING SYSTEM. The system is composed of the following coating types: • Self priming epoxy base coat • Abrasion resistant epoxy barrier coat • Fade resistant urethane top coat

Related to COATING SYSTEM

  • Installation Services 3.1 The Bitstream 2a Service includes a Standard Install as set out below (in each case to the extent that the relevant provisioning works are not already complete for the relevant Service Order).1

  • Moonlighting 24.01 The Company and the Union agree in principle to eliminate the practice commonly referred to as moonlighting.

  • Net Metering If you generate electricity from a renewable generating facility to offset your electricity consumption and/or use net metering at any time during the term of this Agreement, you must notify Starion.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.

  • Functionality Customer is entitled to additional functionality previously purchased or bundled with the software if available in the version or update released on or after the start date of the Agreement. Customer acknowledges that certain functionality in current and previous software versions may not be available in future upgrades. Added functionality may require additional paid services (clinical and technical) to configure and support.

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • Smoke Detectors At Owner's expense, smoke detectors will be installed on the Property in working condition in accordance with the law prior to the tenant's occupancy. During the occupancy, it shall be the tenant's responsibility to maintain all smoke detectors. Owner will replace smoke detector equipment as needed.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • Solution The Supplier’s contractually committed technical approach for solving an information technology business objective and associated Requirements as defined and authorized by the scope of the Contract or any order or Statement of Work issued under the Contract. Solution means all Supplier and Supplier’s third-party providers’ components making up the Solution, including but not limited to Software, Product, configuration design, implementation, Supplier-developed interfaces, Services and Work Product.

Time is Money Join Law Insider Premium to draft better contracts faster.