Analysis of Samples Sample Clauses

Analysis of Samples. 1. Upon opening the ante-mortem samples the analyst checks all seals and markings against the documentation and database information. The final report issued will eventually contain the information as per individual sample label and seal.
AutoNDA by SimpleDocs
Analysis of Samples. 2.4.1 Total Moisture determination shall be done by the TPA as per applicable laboratory and remaining tests/ analysis for determination of moisture, ash, GCV on equilibrated Basis shall be done by the TPA at NABL-accredited laboratory/designate laboratory.
Analysis of Samples. Samples of Wastewater discharged into the Sewage System from the West Manchester Township Collection System may be obtained and analyzed by the Parties at any place, at any reasonable time, in order to ensure compliance with the terms and provisions of this Agreement.
Analysis of Samples. The independent inspector shall witness quality tests for sulfur, salt and xxxx vapor pressure on the samples according to the latest revision of ASTM or API procedures, at Seller's choice. Gravity tests on all Maya shall be made in accordance with the latest revision of API-MPMS, Chapter 9, Section 1 or ASTM procedures D-1298-80, at Seller's choice. S & W shall be established in each case pursuant to the latest revision of ASTM-D-4007 or API-MPMS, Chapter 10-3, at Seller's choice, in tests witnessed by the independent inspector. Quality tests conducted in accordance with the above provisions shall be final and binding upon the parties, except in the case of manifest error.
Analysis of Samples. Cotinine is a metabolite of nicotine and a sensitive marker of ETS exposure. Cotinine was measured in the plasma of asthmatic children previously enrolled and characterized in SARP. Cotinine was measured using a commercially-available competitive, enzyme-linked immunosorbent assay (ELISA) (Calbiotec).23 A competitive ELISA is “an analytic procedure in which an unlabeled and a labeled analyte competes for sites to bind to a specific protein” where the higher the original antigen concentration is, the lower the measured output signal will be (Figure 1).37 A competitive ELISA is advantageous when measuring plasma cotinine levels because it allows you to analyze unpurified samples with many other background antigens and still target the antigen of interest. A Calbiotech Cotinine ELISA kit was used to analyze the Cotinine levels in SARP serum samples. The kit was a solid phase competitive ELISA and the xxxxx of the 96-well plate were coated with an antibody derived against cotinine. As per the kit instructions, 10 μl of each concentration of pre-made cotinine standard (0.0, 5.0, 10.00, 25.00, 50.00, 100.00 ng/m) was pipetted in duplicate into a 96-well plate. 10μl of each plasma sample was pipetted, in singlet, into the 96-well plate. Next, 100 μL of a second cotinine antibody conjugated to horseradish peroxidase enzyme was added to each well. The plate was agitated for 30 seconds to ensure proper mixing. The plate was incubated for one hour at room temperature in the dark. All xxxxx were then washed six times with 300 μL of distilled water using a multi-channel pipette and an augmented plate washer. Following an inversion onto absorbent paper, 100 μL of the chromagenic substrate for the horseradish peroxidase 3,3’,5,5’-tetramethylbenzidene reagent was added to each well. The plate was then incubated for 30 minutes in the dark at room temperature for color development. After the 30 minute time period, 100 μL of stop solution was added to each well and then the plate was shaken to ensure complete mixing. The absorbance was then read on a Teacan plate reader at a wavelength of 450 nm. The cotinine values of the samples were interpolated from the standard curve. Data analysis. Data analysis was performed with SigmaStat software using two-tailed tests of significance and an alpha level of 0.05. Data were graphically inspected and logarithmically transformed when departures from normality were identified. Associations between continuous variables (cotinine and bioma...
Analysis of Samples. The independent inspector shall witness quality tests for sulfur, salt and Xxxx vapor pressure on the samples according to the latest revision of ASTM or API-MPMS procedures, at Seller’s choice. Gravity tests on all Oil shall be made in accordance with the latest revision of API-MPMS, Chapter 9.1, or ASTM D1298-80, at Seller’s choice. S & W shall be established in each case pursuant to the latest revision of ASTM D-4377 or API Chapter 10-3, at Seller’s choice, in tests witnessed by the independent inspector; it being understood that if the Oil is reconstituted crude oil, deduction for S & W shall be made only to the crude oil component of such Oil. Quality tests conducted in accordance with the above provisions shall be final and binding upon the Parties for invoicing purposes, but without prejudice to the right of either Party to pursue a claim.
Analysis of Samples. (a) PURCHASER, at its expense, shall analyze the laboratory samples sent to PURCHASER's designated laboratory in accordance with the procedures set forth in Annex G, which is attached hereto and made a part of this Agreement; and the results of such analyses shall be used for the governing purposes of this Agreement. Annex G delineates laboratory sample preparation and analytical procedures that are in accordance with ASTM and industry standards and shall be used by the Parties as provided in this Agreement. PURCHASER shall mail a copy of each such analysis to SALES AGENT within three working days after the sample is received at the designated laboratory, which may be PURCHASER's Central Laboratory in Smyrna, Georgia. or an independent coal-testing laboratory selected by PURCHASER. If PURCHASER elects to employ an independent coal-testing laboratory, SELLER shall not be liable for any costs incurred by PURCHASER except as otherwise provided in this Agreement.
AutoNDA by SimpleDocs
Analysis of Samples. The independent inspector shall witness quality tests for sulfur, salt and Xxxx vapor pressure on the samples according to the latest revision of ASTM or API-MPMS procedures, at Seller’s choice. Gravity tests on all Oil shall be made in accordance with the latest revision of API-MPMS, Chapter 9.1, or ASTM D1298-80, at Seller’s choice. S & W shall be established in each case pursuant to the latest revision of ASTM D-4007 or API Chapter 10-3, at Seller’s choice, in tests witnessed by the independent inspector. Quality tests conducted in accordance with the above provisions shall be final and binding upon the Parties for invoicing purposes, but without prejudice to the right of either Party to pursue a claim.
Analysis of Samples e.1. Total Moisture determination shall be done by the TPA at the nearest laboratory of the Seller and remaining tests / analysis for determination of moisture, ash, GCV on equilibrated Basis shall be done by the TPA at NABl-accredited laboratory e.2. Analysis of sample(s) shall be carried out as per latest version of IS 1350 (Part-I)-1984 for determination oi Total Moisture, Equilibrated Moisture, Ash and Volatile Matter and as per latest version of IS 1350 (Pa(-II), 1970 for determination of GCV'
Analysis of Samples. (a) Purchaser, at its expense, shall analyze the laboratory samples sent to Purchaser's designated laboratory in accordance with the procedures set forth in Annex G, which is attached hereto and made a part of this Agreement; and the results of such analyses shall be used for the governing purposes of this Agreement. Annex G delineates laboratory sample preparation and analytical procedures that are in accordance with ASTM and industry standards and shall be used by the Parties as provided in this Agreement. Purchaser shall mail a copy of each such analysis to Sales Agent within three working days after the sample is received at the designated laboratory, which may be Purchaser's Central Laboratory in Smyrna, Georgia, or an independent coal-testing laboratory selected by Purchaser. If Purchaser elects to employ an independent coal-testing laboratory, Seller shall not be liable for any costs incurred by Purchaser except as otherwise provided in this Agreement.
Time is Money Join Law Insider Premium to draft better contracts faster.