OPTICAL TIME DOMAIN REFLECTORY MEASUREMENTS Sample Clauses

OPTICAL TIME DOMAIN REFLECTORY MEASUREMENTS. (O.T.D.R.): The purpose of this test is to measure any problem points with respect to the transmission or reflection losses of the fibre link and to locate the position of these points. This test is executed in the field. This measurement is done with an optical reflectometer, connected to both fibres end points and is used to perform remote measurements. The optical reflectometer launches power into the fibre and analyses the reflected signal, which permits the fibre attenuation due to scattering, absorption and reflections to be calculated. Part of the scattered power pulse is sent back to the optical reflectometer where it is detected and displayed on a cathode-ray-screen. The rate of returned power depends on the power launched into the fibre and on the back scattering factor of the latter. The optical reflectometer displays on its screen the optical power of the received signals on a logarithmic scale. -------------------------------------------------------------------------------- 29 August 1996 OPTICAL CABLE SPECIFICATIONS Page 12/24 ALCATEL 1996 Issue 6.0 55 ALCATEL Direct reading of the following can be made: - On the X axis : distance between each point of the fibre and the measuring instrument. - On the Y axis : power scattered by each point of the fibre. Any sudden drop of the curve means punctual attenuation. This measure is performed in both directions of a link. It is the average of both results which is considered. This measure also provides an accurate value of the Return Loss for each O.D.F. situated at both extremities of the measured link.
AutoNDA by SimpleDocs

Related to OPTICAL TIME DOMAIN REFLECTORY MEASUREMENTS

  • USE OF THIRD PARTY SYSTEMS-LEVEL SOFTWARE State Street and the Fund acknowledge that in connection with the Data Access Services provided under this Addendum, the Fund will have access, through the Data Access Services, to Fund Data and to functions of State Street’s proprietary systems; provided, however that in no event will the Fund have direct access to any third party systems-level software that retrieves data for, stores data from, or otherwise supports the System.

  • Measurement All quantities of Products received or delivered by or into truck, rail, or marine vessel shall be measured and determined based upon the meter readings at each Terminal, as reflected by delivery tickets or bills of lading, or if such meters are unavailable, by applicable calibration tables. All quantities of Products received and delivered by pipeline shall be measured and determined based upon the meter readings of the pipeline operator, as reflected by delivery tickets, or if such meters are unavailable, by applicable calibration tables. Deliveries to a Terminal rack at Mandan, Salt Lake City or Wilmington from a Tesoro Refinery shall be deemed to be the same as the corresponding volumes delivered contemporaneously from the Terminal rack. Deliveries by book transfer shall be reflected by entries in the books of TLO. All quantities shall be adjusted to net gallons at 60° F in accordance with ASTM D-1250 Petroleum Measurement Tables, or latest revisions thereof. A barrel shall consist of 42 U.S. gallons and a gallon shall contain 231 cubic inches. Meters and temperature probes shall be calibrated according to applicable API standards. Tesoro shall have the right, at its sole expense, and in accordance with rack location procedure, to independently certify said calibration. Storage tank gauging shall be performed by TLO’s personnel. TLO’s gauging shall be deemed accurate unless challenged by an independent certified xxxxxx. Tesoro may perform joint gauging at its sole expense with TLO’s personnel at the time of delivery or receipt of Product, to verify the amount involved. If Tesoro should request an independent xxxxxx, such xxxxxx must be acceptable to TLO, and such gauging shall be at Tesoro’s sole expense.

  • Directory The bulletin board or directory of the Building will be provided exclusively for the display of the name and location of tenants and Landlord reserves the right to exclude any other names therefrom.

  • Metering 1. If the Producer desires to sell electric power to the Company, the Company shall provide, own and maintain at the Producer's expense all necessary meters and associated equipment to be utilized for the measurement of energy and capacity for determining the Company's payment to the Producer pursuant to an applicable agreement.

  • Cost of Metering The Issuer shall not be obligated to pay any costs associated with the routine metering duties set forth in this Section 2, including the costs of installing, replacing and maintaining meters, nor shall the Issuer be entitled to any credit against the Servicing Fee for any cost savings realized by the Servicer as a result of new metering and/or billing technologies.

  • Service Area The municipalities and counties in and around which Seller operates or is authorized to operate the Systems and the Business, which are disclosed on Schedule 1.39.

  • Places of Business and Locations of Records The principal places of business and chief executive office of such Seller Party and the offices where it keeps all of its Records are located at the address(es) listed on Exhibit III or such other locations of which the Agent has been notified in accordance with Section 7.2(a) in jurisdictions where all action required by Section 14.4(a) has been taken and completed. Seller's Federal Employer Identification Number is correctly set forth on Exhibit III.

  • Network Access Control The VISION Web Site and the Distribution Support Services Web Site (the “DST Web Sites”) are protected through multiple levels of network controls. The first defense is a border router which exists at the boundary between the DST Web Sites and the Internet Service Provider. The border router provides basic protections including anti-spoofing controls. Next is a highly available pair of stateful firewalls that allow only HTTPS traffic destined to the DST Web Sites. The third network control is a highly available pair of load balancers that terminate the HTTPS connections and then forward the traffic on to one of several available web servers. In addition, a second highly available pair of stateful firewalls enforce network controls between the web servers and any back-end application servers. No Internet traffic is allowed directly to the back-end application servers. The DST Web Sites equipment is located and administered at DST’s Winchester data center. Changes to the systems residing on this computer are submitted through the DST change control process. All services and functions within the DST Web Sites are deactivated with the exception of services and functions which support the transfer of files. All ports on the DST Web Sites are disabled, except those ports required to transfer files. All “listeners,” other than listeners required for inbound connections from the load balancers, are deactivated. Directory structures are “hidden” from the user. Services which provide directory information are also deactivated.

  • Product Marking LICENSEE agrees to xxxx the LICENSED PRODUCTs sold in the United States with all applicable United States patent numbers. All LICENSED PRODUCTs shipped to or sold in other countries shall be marked in such a manner as to conform with the patent laws and practices of the country of manufacture or sale.

  • Royalty Rates Within [***] ([***]) [***] after the end of each calendar quarter, commencing with the calendar quarter during which the First Commercial Sale of a Licensed Product is made anywhere in the Territory and during the applicable Royalty Term, Hansoh shall make royalty payments to Viela based on Net Sales of all Licensed Products sold in the Territory in accordance with the table below. Within [***] ([***]) [***] after the end of each calendar quarter during the Term, Hansoh shall provide to Viela a report that contains the following information for the applicable calendar quarter, on a region-by-region basis: (i) the amount of Net Sales of such Licensed Product, (ii) a calculation of the royalty payment due on such Net Sales, including any royalty reduction made in accordance with Section 5.4(d), and (iii) the exchange rate used for converting any Net Sales recorded in a currency other than Dollars. In the case that the annualized royalty rate during a particular calendar year is more than that set forth in the table below, the corresponding overpayment received by Viela shall be credited to Hansoh against subsequent royalty payments; and in the case that the annualized royalty rate during a particular calendar year is less than that set forth in the table below, Hansoh shall pay the difference within [***] ([***]) [***] after receipt of Viela’s invoice. Threshold of the Net Sales of all Licensed Products Royalty % [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [***] [*] = CERTAIN CONFIDENTIAL INFORMATION CONTAINED IN THIS DOCUMENT, MARKED BY BRACKETS, HAS BEEN OMITTED BECAUSE THE INFORMATION (I) IS NOT MATERIAL AND (II) WOULD BE COMPETITIVELY HARMFUL IF PUBLICLY DISCLOSED.