Main Switchboard Operation Sample Clauses

Main Switchboard Operation. The main switchboard shall provide all the instrumentation, controls, and circuitry required for control and monitoring of the ship service electrical generation and distribution system. One (1) generator provides normal electrical service. The system shall have the ability to run any two (2) generators in parallel. Switchboard interlocks shall prevent the operation of three (3) generators in parallel. Each SSDG set shall have Run, Standby, and Shut Down operating modes, selectable with a switch on the switchboard. When in Standby mode each SSDG will be ready to automatically start, parallel, and assume its proportional part of the load when load reaches 90% of the capacity of the on-line generator set for 30 seconds. The standby startup load and time delay shall be 640 645 650 655 660 665 670 adjustable. Additionally, it shall automatically start, accelerate to rated speed, and connect to the bus upon main bus voltage failure within eight (8) seconds. The switchboard shall be equipped to allow manual and automatic parallel operation. In Manual Mode the generators operate with speed and voltage droop. The operator manually synchronizes and manually adjusts engine speed and generator voltage. In Automatic Mode the generators synchronize and parallel automatically, and operate isochronously with constant voltage. Primary control power for switchboards shall be derived from internal control transformers provided with appropriate overcurrent protection. Secondary control power shall be provided from DC uninterruptible power supplies (UPS), NewMar Nav-Pac or equal, as shown in Reference (3D). The switchboard automation shall provide the ability for closed (bumpless) transition between ship supply and shore power, or the reverse. The ship and shore supplies shall operate in parallel for not more than 100 milliseconds. The switchboard shall include monitoring of shore power voltage, frequency, and phase sequence. Before paralleling the ship service bus to shore power, the automatic voltage regulator shall adjust the voltage on the ship service bus to match that of the shore power connection. Switchboard interlocks shall prevent manual paralleling of the ship service bus and shore power, and shall prevent the operation of the automatic transition function when voltage is not present on both the ship service bus and shore power feed at the switchboard. Interlocks shall also prevent transitioning from generator power to shore power when the load on the ship service ...
AutoNDA by SimpleDocs

Related to Main Switchboard Operation

  • Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least thirty (30) days written notice to the SLDC and GUVNL, of the date on which it intends to synchronize the Power Project to the Grid System.

  • Shiftwork 38.1 Shift Penalties (Excluding Home Care Classifications)

  • Verizon Operations Support Systems Verizon systems for pre- ordering, ordering, provisioning, maintenance and repair, and billing.

  • Emergency Mode Operation Plan Contractor must establish a documented plan to enable continuation of critical business processes and protection of the security of electronic DHCS PHI or PI in the event of an emergency. Emergency means any circumstance or situation that causes normal computer operations to become unavailable for use in performing the work required under this Agreement for more than 24 hours.

  • Television Equipment Recycling Program If this Contract is for the purchase or lease of covered television equipment, then Contractor certifies that it is compliance with Subchapter Z, Chapter 361 of the Texas Health and Safety Code related to the Television Equipment Recycling Program.

  • Local Switching Interfaces 4.2.13.1 Deland Actel shall order ports and associated interfaces compatible with the services it wishes to provide as listed in Exhibit A. BellSouth shall provide the following local switching interfaces:

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Processing operations The personal data transferred will be subject to the following basic processing activities:

  • Switching System Hierarchy and Trunking Requirements For purposes of routing iNetworks traffic to Verizon, the subtending arrangements between Verizon Tandems and Verizon End Offices shall be the same as the Tandem/End Office subtending arrangements Verizon maintains for the routing of its own or other carriers’ traffic (i.e., traffic will be routed to the appropriate Verizon Tandem subtended by the terminating End Office serving the Verizon Customer). For purposes of routing Verizon traffic to iNetworks, the subtending arrangements between iNetworks Tandems and iNetworks End Offices shall be the same as the Tandem/End Office subtending arrangements that iNetworks maintains for the routing of its own or other carriers’ traffic.

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

Time is Money Join Law Insider Premium to draft better contracts faster.