Instrumentation and measurement sensors Sample Clauses

Instrumentation and measurement sensors. Met mast/s The met masts will be equipped according to the requirements of [Ref.1], particularly in its Annex G. The following measurement sensors will be required on each of the met masts (including WTG met masts in case Site Calibration is required): SENSOR REFERENCE MET MAST WTG MET MAST Top anemometer X X Control anemometer X X Top wind vane X X Control wind vane X Low tip height anemometer (HH-R) X X Intermediate anemometer (HH-R/2) X X Low tip height wind vane (HH-R) X X Temperature Sensor (close to HH) X X Humidity sensor (close to HH) X Pressure sensor (close to HH) X Data logger X X Upflow anemometer (close to HH) X X The anemometers will be all the same model, class according to Xxxxx X of [Ref.1], and will be all calibrated in a Measnet accredited wind tunnel. In the case of instruments calibrated by this laboratory are not available, other options can be agreed between both Parties. The rest of sensors will be calibrated by an ILAC accredited entity. All three anemometers and wind vanes used to measure the wind shear and wind veer must be installed in identical boom types at the same side of the tower. The vertical component of the wind speed shall be measured close to hub height. The relative humidity shall always be considered in the calculation of air density. In case of need for Site Calibration, the wind vane used for the Power Curve measurement phase will be the same that used during the Site Calibration phase, not being removed during the interim period. The configuration of any meteorological mast shall be top mounted single anemometer. Traditionally known as goal-post configurations are not allowed. The top anemometer height shall not deviate more than +0.0/-0.5 [m] from the turbine Hub Height. The measurement distance from ground shall be referenced to the average elevation of the ground around the met mast base. Uncertainty of such measurement shall be assessed and documented. If lightning finials or other objects (e.g. aviation lights) are fitted on the met mast, such objects should be installed in accordance to the IEC requirements and to the satisfaction of the IE. Seller will have the right to review and comment final layout and configuration, and the Owner shall either implement the recommendations from the Seller or provide written explanation from IE. Upflow angle shall be measured as close to hub height as possible with a 3D sonic sensor, or similar device.
AutoNDA by SimpleDocs

Related to Instrumentation and measurement sensors

  • Joint Network Implementation and Grooming Process Upon request of either Party, the Parties shall jointly develop an implementation and grooming process (the “Joint Grooming Process” or “Joint Process”) which may define and detail, inter alia:

  • Electronic and Information Resources Accessibility and Security Standards a. Applicability: The following Electronic and Information Resources (“EIR”) requirements apply to the Contract because the Grantee performs services that include EIR that the System Agency's employees are required or permitted to access or members of the public are required or permitted to access. This Section does not apply to incidental uses of EIR in the performance of the Agreement, unless the Parties agree that the EIR will become property of the State of Texas or will be used by HHSC’s clients or recipients after completion of the Agreement. Nothing in this section is intended to prescribe the use of particular designs or technologies or to prevent the use of alternative technologies, provided they result in substantially equivalent or greater access to and use of a Product.

  • Instrumentation The acceleration shall be recorded during the test, using equipment in accordance with channel frequency class 1000 as specified in the latest version of ISO 6487.

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

  • Prescription and Over-the-Counter Medications Employees taking physician-prescribed or over-the-counter medications, if there is a substantial likelihood that such medication will affect job safety, must notify their supervisor or other designated official of the fact that they are taking a medication and the side effects of the medication.

  • Required Procurement Procedures for Obtaining Goods and Services The Grantee shall provide maximum open competition when procuring goods and services related to the grant-assisted project in accordance with Section 287.057, Florida Statutes.

  • Documentation and Record Keeping 1. Records to be Maintained Subrecipient shall maintain all records required by the Federal regulations specified in 24 CFR 570.506 that are pertinent to the activities to be funded under this Contract. Such records shall include, but not be limited to:

  • Trunk Group Architecture and Traffic Routing The Parties shall jointly engineer and configure Local/IntraLATA Trunks over the physical Interconnection arrangements as follows:

  • SERVICE MONITORING, ANALYSES AND ORACLE SOFTWARE 11.1 We continuously monitor the Services to facilitate Oracle’s operation of the Services; to help resolve Your service requests; to detect and address threats to the functionality, security, integrity, and availability of the Services as well as any content, data, or applications in the Services; and to detect and address illegal acts or violations of the Acceptable Use Policy. Oracle monitoring tools do not collect or store any of Your Content residing in the Services, except as needed for such purposes. Oracle does not monitor, and does not address issues with, non-Oracle software provided by You or any of Your Users that is stored in, or run on or through, the Services. Information collected by Oracle monitoring tools (excluding Your Content) may also be used to assist in managing Oracle’s product and service portfolio, to help Oracle address deficiencies in its product and service offerings, and for license management purposes.

  • Documentation and compliance (a) The data importer shall promptly and adequately deal with enquiries from the data exporter that relate to the processing under these Clauses.

Time is Money Join Law Insider Premium to draft better contracts faster.