GAS METERING SYSTEM Sample Clauses

GAS METERING SYSTEM. Ultrasonic Gas Metering System Ultrasonic gas flow meters x 2 units Pressure transmitters x 2 units Temperature transmitters x 2 units Gas Analyzer System Sample probe x 2 unit Gas chromatographs x 2 units Supplementary Gas Chromatograph x 1 unit Analyzer cabinet x 1 unit Metering Control System Metering cabinet x 1 unit Flow computers x 2 units Supplementary flow computers x 2 units 1.10 BALLAST SYSTEM Pumps Particular No Three (3) Type Vertical single stage, centrifugal Prime mover Electric motor Discharge rate 2,500 m3/h Total head 30 mwc (S.G.: 1.025)
AutoNDA by SimpleDocs
GAS METERING SYSTEM. [TBN] Ultrasonic Gas Metering System [TBN - as per the Shipbuilding Spec] Gas Analyzer System [TBN - as per the Shipbuilding Spec] Metering Control System [TBN - as per the Shipbuilding Spec] Measurement Accuracy [TBN] Standard references AGA9 and AGA10

Related to GAS METERING SYSTEM

  • Metering 1. If the Producer desires to sell electric power to the Company, the Company shall provide, own and maintain at the Producer's expense all necessary meters and associated equipment to be utilized for the measurement of energy and capacity for determining the Company's payment to the Producer pursuant to an applicable agreement.

  • Interconnection If Manager desires to interconnect a portion of the Service Area Network with another carrier and Sprint PCS can interconnect with that carrier at a lower rate, then to the extent permitted by applicable laws, tariffs and contracts, Sprint PCS may arrange for the interconnection under its agreements with the carrier and if it does so, Sprint PCS will xxxx the interconnection fees to Manager.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Delivery Point Once Manufacture of the Products has been completed, Contractor shall be responsible for delivering the Finished Goods FCA, (as defined in Incoterms (2000) published by the International Chamber of Commerce) and to a freight forwarder specified by Company in its Order, or otherwise approved by Company. “Delivery Point” as used in this Agreement shall mean the specific time and location that the Product is delivered to the shipper specified on the Order.

  • Cost of Metering The Issuer shall not be obligated to pay any costs associated with the routine metering duties set forth in this Section 2, including the costs of installing, replacing and maintaining meters, nor shall the Issuer be entitled to any credit against the Servicing Fee for any cost savings realized by the Servicer as a result of new metering and/or billing technologies.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • HEATING Landlord shall furnish heat to the Premises when and as required by law, on business days from 8:00 A.M. to 6:00 P.M. Landlord shall not be responsible for the adequacy, design or capacity of the heating distribution system if the normal operation of the heat distribution system serving the Building shall fail to provide heat at reasonable temperatures or any reasonable volumes or velocities in any parts of the Premises by reason of any rearrangement of partitioning or other Alterations made or performed by or on behalf of Tenant or any person claiming through or under Tenant.

  • Delivery Points The measurement of and tests for quality of Shipper's Gas redelivered at the Delivery Points shall be governed by and determined in accordance with the requirements of the receiving pipeline at each Delivery Point.

  • Fuel Upon redelivery of the Aircraft to Lessor, an adjustment will be made in respect of fuel on board on the Previous Delivery Date and the Expiry Date at the price then prevailing at the Redelivery Location.

  • Sprinkler System If there now is or shall be installed in the Building a "sprinkler system", and such system or any of its appliances shall be damaged or injured or not in proper working order by reason of any act or omission of Tenant, Tenant's agents, servants, employees, licensees or visitors, Tenant shall forthwith restore the same to good working condition at its own expense; and if the New York Board of Fire Underwriters or the New York Fire Insurance Rating Organization or any bureau, department or official of the state or city government, shall require or recommend that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of Tenant's business, or the location of the partitions, trade fixtures, or other contents of the Premises, Tenant shall, at Tenant's expense, promptly make and supply such changes, modifications, alterations, additional sprinkler heads or other equipment.

Time is Money Join Law Insider Premium to draft better contracts faster.