Economizer Sample Clauses

Economizer. $85.00 per hour, plus a $25.00 programming fee Full HVAC: $180.00 per hour on weeknights, plus engineering and labor costs Full HVAC: $230.00 per hour on weekends/Holidays, plus engineering and labor costs
AutoNDA by SimpleDocs
Economizer. 3. Superheat/Reheat Panels
Economizer. Ash Handling System - This System removes fly ash from the economizer hoppers, then transfers the ash pneumatically to the pyrites transfer tank. From the pyrites transfer tank the ash is transferred hydraulically to dewatering bins. (c) Fly Ash Handling System - This System removes the mixture of fly ash and dry SO2 scrubber product from the baghouse hoppers, duct hoppers and spray dryer recycle bin hopper through a pressurized pneumatic system to fly ash stoxxxx xilos located adjacent to the bottom ash dewatering bins. In the fly ash silo, entrained air is vented off through a baghouse filter system. The major equipment components of this System are air conveyor flowers, a fly ash silo, bag filters, hopper feeders, fluidizing blowers, exhaust fans, and other xxxxxxated piping and miscellaneous equipment and controls. (d) Burial Area and Retention Dams - Bottom ash and the mixture of fly ash and dry SO2 scrubber product are trucked to an ash burial area, having a potential storage capacity of 10,000 acre-feet. The ash burial area includes an embankment will be constructed downstream of the ash burial area to retain surface runoff.
Economizer. Function: Heat recovery from tail gas to exhaust stack by preheating boiler feedwater Description: Fintube heat exchanger Construction: Tubes: SA-178A Shell: CS H1804 NOx Abator Function: To reduce nitrogen oxides in the tail gas prior to discharge to atmosphere Description: Atmospheric catalyst and housing Construction: CS Housing M1805 Ammonia/Tail Gas Mixer Function: To provide homogeneous mixing of ammonia vapor and tail gas for reaction in the NOx abator Description: In-line static mixer Construction: 304 SS M1806 Ammonia/Tail Gas Premixer Function: To provide homogeneous pre-mixing of ammonia and air for mixing with tail gas Description: In-line static mixer Construction: CS E1807 Start-Up Heater Function: To preheat tail gas to enable operation of NOx abator to minimize emissions during start-up 723-Weak Acid Contract Page 33 of 113 Contract: Xxxxxxxxx Inc - El Dorado Chemical Description: Fintube heat exchanger Construction: Tubes: SA-178A Shell: CS B1812 Abator Tail Gas Blower Function: To supply recycled tail gas for pre-mixing with ammonia feed to the NOx abator Description: Centrifugal fan Construction: 304 SS 723-Weak Acid Contract Page 34 of 113 Contract: Xxxxxxxxx Inc - El Dorado Chemical
Economizer. Ash The economizer ash facility handles and recycles economizer ash. The facility includes the economizer hoppers, silos, transfer equipment, related auxiliaries and structures.

Related to Economizer

  • Virus Management Transfer Agent shall maintain a malware protection program designed to deter malware infections, detect the presence of malware within the Transfer Agent environment.

  • Research and Development (i) Advice and assistance in relation to research and development of Party B;

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Business Development Provide advice and assistance in business growth and development of Party B. 业务发展。对乙方的业务发展提供建议和协助。

  • Condominiums/Planned Unit Developments If the Mortgaged Property is a condominium unit or a planned unit development (other than a de minimis planned unit development) such condominium or planned unit development project such Mortgage Loan was originated in accordance with, and the Mortgaged Property meets the guidelines set forth in the Originator's Underwriting Guidelines;

  • Staffing Consultant will designate in writing to Authority its representative, and the manner in which it will provide staff support for the project, which must be approved by Authority. Consultant must notify Authority’s Contract Representative of any change in personnel assigned to perform work under this Contract, and the Authority’s Contract Representative has the right to reject the person or persons assigned to fill the position or positions. The Authority’s Contract Representative shall also have the right to require the removal of the Consultant’s previously assigned personnel, including Consultant’s representative, provided sufficient cause for such removal exists. The criteria for requesting removal of an individual will be based on, but not limited to, the following: technical incompetence, inability to meet the position’s qualifications, failure to perform, poor attendance, ethics violation, unsafe work habits, or damage to Authority or other property. Upon notice for removal, Consultant shall replace such personnel with personnel substantially equal in ability and qualifications for the positions and shall submit the proposed replacement personnel qualification and abilities to the Authority, in writing, for approval.

  • Conhecimento da Lingua O Contratado, pelo presente instrumento, declara expressamente que tem pleno conhecimento da língua inglesa e que leu, compreendeu e livremente aceitou e concordou com os termos e condições estabelecidas no Plano e no Acordo de Atribuição (“Agreement” xx xxxxxx).

  • Information Systems Acquisition Development and Maintenance Security of System Files. To protect City Information Processing Systems and system files containing information, Service Provider will ensure that access to source code is restricted to authorized users whose specific job function necessitates such access.

Time is Money Join Law Insider Premium to draft better contracts faster.