VERTICAL BORINGS Sample Clauses

VERTICAL BORINGS. The subsurface field exploration will consist of drilling up to three (3) borings to a depth of 15 up to 25 feet below the existing ground surface, to refusal, or until groundwater effectively prohibits hollow stem auger drilling, whichever comes first. Target drilling depth will be approximately 5 feet below the currently proposed pipe depth as outlined in Figure 1. The borings will be drilled using a 2-wheel drive drill rig, equipped with hollow-stem auger and automatic hammer. The intent of the exploration is to collect bulk samples of base material and subgrade soils, as well as drive samples of underlying soils for laboratory testing. Bulk samples of base material, if encountered, will be collected. The amount of base material collected will be dependent on the thickness of the material present at the time of our investigation. Soils encountered in the field will be visually classified in accordance with the Unified Soils Classification System. Samples of the underlying soils will be collected and brought back to our laboratory for testing.
AutoNDA by SimpleDocs

Related to VERTICAL BORINGS

  • CURVE WIDENING The minimum widening placed on the inside of curves is:  6 feet for curves of 50 to 79 feet radius.  4 feet for curves of 80 to 100 feet radius.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • Inoculations The Employer agrees to pay full expenses for inoculation or immunization shots for the employee and for members of an employee’s household when such becomes necessary as a result of said employee’s exposure to contagious diseases (including AIDS, tuberculosis and hepatitis) where said officer has been exposed to said disease in the line of duty.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Underground Utilities Any required ground digging or subsurface work shall be done in accordance with Chapter 556, Florida Statutes. It shall be the responsibility of CONTRACTOR to have all underground utilities located before any work begins (Sunshine State One Call 0-000-000-0000). The repairs of any damaged underground utilities as a result of the work being performed by CONTRACTOR shall be the responsibility of CONTRACTOR. The proper utility company shall be contacted immediately to expedite the repairs, if damage has occurred. CONTRACTOR will notify the COUNTY and provide a written explanation of the incident within two (2) days of the damage to any underground utilities.

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • UNDERGROUND LOCATIONS Prior to the Company commencing any work the Customer must advise the Company of the precise location of all underground services on the site and clearly xxxx the location. The underground mains and services the Customer must identify include, but are not limited to, telephone cables, fibre optic cables, electrical services, gas services, sewer services, pumping services, sewer connections, sewer sludge mains, water mains, irrigations pipes, oil pumping mains and any other services that may be on site. Whilst the Company will take all care to avoid damage to any underground services the Customer agrees to indemnify the Company in respect of all any liability claims, loss, damage, cost and fines as a result of damage to services not precisely located and notified pursuant to this clause.

  • ROAD DIMENSIONS Purchaser shall perform road work in accordance with the dimensions shown on the TYPICAL SECTION SHEET and the specifications within this road plan.

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Copper Subloops Sprint will make available access to copper subloops on an unbundled basis. A copper subloop is a portion of a Copper Loop, or Hybrid Loop, and is comprised entirely of copper wire or copper cable that acts as a transmission facility between any accessible terminal in Sprint’s outside plant, including inside wire owned or controlled by Sprint, and the end-user customer premises. A copper subloop can also include intermediate devices, such as repeaters, used to establish the transmission path. Copper subloops can be used by CLEC to provide voice-grade services as well as digital subscriber line services. Access to copper subloops is subject to the collocation provisions of this Agreement. Copper subloop consists of the distribution portion of the copper loop. Sprint is not obligated to offer feeder loop plant as a stand-alone UNE.

Time is Money Join Law Insider Premium to draft better contracts faster.