Discharging. The procedure for discharging the REESS for vehicle-based test shall be in accordance with paragraphs 3.2.1. and 3.
Discharging. At the beginning of the test, all relevant main contactors shall be closed. A discharge shall be performed with at least 1/3 C rate but shall not exceed the maximum current within the normal operating range as specified by the manufacturer. The discharging shall be continued until the tested-device (automatically) interrupts or limits the discharging. Where an automatic interrupt function fails to operate, or if there is no such function then the discharging shall be continued until the tested-device is discharged to 25 per cent of its nominal voltage level.
Discharging. At the beginning of the test, all relevant main contactors shall be closed. A discharge shall be performed with at least 1/3 C rate but shall not exceed the maximum current within the normal operating range as specified by the manufacturer. The discharging shall be continued until the tested-device (automatically) interrupts or limits the discharging. Where an automatic interrupt function fails to operate, or if there is no such function then the discharging shall be continued until the tested-device is discharged to 25 per cent of its nominal voltage level. 3.3. Standard charge and observation period Directly after termination of the discharging the tested-device shall be charged with a standard charge as specified in Annex 8, Appendix 1 if not inhibited by the tested-device. Public Comment Only The test shall end with an observation period of 1 h at the ambient temperature conditions of the test environment.
Discharging. When the Company finds it necessary to discharge a ▇▇▇▇▇▇▇, the Business Representative of the Union shall be notified prior to such action taking place.
Discharging. At the beginning of the test, all relevant main contactors shall be closed. A discharge shall be performed with at least 1/3 C rate but shall not exceed the maximum current within the normal operating range as specified by the manufacturer. The discharging shall be continued until the tested-device (automatically) interrupts or limits the discharging. Where an automatic interrupt function fails to operate, or if there is no such function then the discharging shall be continued until the tested-device is discharged to 25 per cent of its nominal voltage level. E/ECE/324/Rev.2/Add.99/Rev.2 E/ECE/TRANS/505/Rev.2/Add.99/Rev.2 Annex 8H
Discharging. The long-term continuous discharge current of the battery should be ≤0.5C (i.e. single module 25A current) • The recommend maximum discharge depth of PACK is no more than 90%.