Compressor Units. Within seven days from the date hereof, WEUS shall deliver to Parent a true and complete list as of a recent date of all compressor units owned or leased by the Company or any of its subsidiaries, indicating the type of each such compressor and its current location.
AutoNDA by SimpleDocs
Compressor Units. To each parallel system compressor provide one 208-230/3/60 branch circuit one 120V or one 208V 1PH 15A circuit - see Note 1 To each remote air-cooled condenser provide one 208-230/3/60 branch circuit
Compressor Units. To each parallel system compressor provide one 460/3/60 branch circuit one 120V or one 208V 1PH 15A circuit - see Note 1 To each remote air-cooled condenser provide one 460/3/60 branch circuit NOTE 1 - Omit when single point connection kit is used. Electronic Controls For ALL electronic controllers consult that manufacturers manual for wiring. REQUIRED FIELD WIRE SIZE Based on the full load amps of the system, select the largest connectable wire size from the table. (Based on no more than three wires in the raceway and 30°C environment per NEC.) Total Connected FLA Largest Connectable Wire 140A (max) 00 per ∅ 248A (max) 350 mcm ∅ 408A (max) 2 X (250 mcm) per ∅ 608A (max) 2 X (500 mcm) per ∅ Include control circuit amps if single point connection transformer option is used. 12A for 208V systems 6A for 460V systems WHEN TO ORDER SINGLE POINT CONNECTION KIT POWER SINGLE POINT SUPPLY CONNECTION KIT 4 Wire 3PH208V L1-------- L2-------- Not Needed L3-------- N--------- 3 Wire 3PH230/460V and L1-------- L2-------- Not Needed 2 Wire 1PH L3-------- 120 Volt H--------- N--------- 3 Wire 3PHDelta L1-------- L2-------- Required L3-------- Required Ground Wiring not shown

Related to Compressor Units

  • ADJACENT EXCAVATION-SHORING 32. If an excavation shall be made upon land adjacent to the demised premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the demised premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which demised premises form a part from injury or damage and to support the same by proper foundations without any claim for damages or indemnity against Owner, or diminution or abatement of rent.

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from CBB to Verizon, CBB, at CBB’s own expense, shall:

  • Gas If Customer has selected a Gas Fixed Rate, Customer’s Price will be based on the Fixed Rate(s), plus the Administration Charge, set forth in the Application, which includes RITERATE ENERGY’s compressor fuel and transportation charges, administrative and transaction costs and the Gas Balancing Amount and any Regulatory Charges (defined below).

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and ICG, ICG shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks, and the Entrance Facility on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • Capacity Interconnection Rights Pursuant to and subject to the applicable terms of the Tariff, the Interconnection Customer shall have Capacity Interconnection Rights at the Point(s) of Interconnection specified in this Interconnection Service Agreement in the amount of 550 MW.

  • Terminal Transfers You can get a receipt at the time you make any transfer at a First Hawaiian ATM, Network ATM, or POS terminal.

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Dark Fiber Transport Dark Fiber Transport is defined as Dedicated Transport that consists of unactivated optical interoffice transmission facilities without attached signal regeneration, multiplexing, aggregation or other electronics. Except as set forth in Section 6.9.1 below, BellSouth shall not be required to provide access to Dark Fiber Transport Entrance Facilities pursuant to this Agreement.