Virtual Resources Sample Clauses

Virtual Resources. The virtual resources information model is used to describe the optical resource virtualization service. This model includes the description of all the virtual resources that can be created inside a Data Centre, for example virtual nodes (network nodes (V Net Node) and IT nodes/VMs (VM)) and virtual links (V Link). The SDN based Control Plane will focus on the network related resources. The optical resource virtualization service APIs can be expressed through the common CRUD actions to be invoked over a virtual resource, for example “create a virtual node with a given number of virtual ports”, “delete the virtual link with a given ID”, etc. Asynchronous events can be also modelled as modifications in the status of an existing resource (e.g. a node failure can change the operational state of that node resources). Therefore they can be retrieved through proper subscriptions associated to a given type of resources or attributes in the database. Moreover, further commands can define other specific operations on some resources, for example “connect port A with port B in node N”. Some key attributes for describing each element have been identified in Figure 14: • Virtual DC topology o Topology (interconnections of the links and nodes) o Number of nodes (virtual network and IT) o Capacity (each node and each link) • V Net Node o Number of ports o Bitrate per ports o Other advanced features and functionalities which abstract the technology capability • VM o CPU requirement o Memory requirement o Capacity requirement • V Link o Bandwidth o Latency o Other advanced features and functionalities which abstract the technology capability Figure 14. Information model for virtual DC resources Depending on the physical technology which is at the basis of the virtual resource, the advanced parameters which characterize virtual network nodes and links may be slightly different, however they will provide a certain level of abstraction and try to use common and unified concepts. This approach allows the other services which will use the basic virtual optical resources (e.g. to compose a virtual slice) to exploit the optical characteristics of the DCN, while using common mechanisms, procedures and algorithms.
AutoNDA by SimpleDocs
Virtual Resources 

Related to Virtual Resources

  • Cultural Resources If a cultural resource is discovered, the Purchaser shall immediately suspend all operations in the vicinity of the cultural resource and notify the Forest Officer. Operations may only resume if authorized by the Forest Officer. Cultural resources identified and protected elsewhere in this contract are exempted from this clause. Cultural resources, once discovered or identified, are not to be disturbed by the Purchaser, or his, her or its employees and/or sub- contractors.

  • Financial Resources The Adviser has the financial resources available to it necessary for the performance of its services and obligations contemplated in the Pricing Disclosure Package, the Prospectus, and under this Agreement, the Investment Management Agreement and the Administration Agreement.

  • Additional Resources The WLSC may establish subcommittees that include other department representatives and/or subject matter experts. These subcommittees shall conform with rules established by the WLSC.

  • Capital Resources Parent has sufficient cash to pay the aggregate Merger Consideration.

  • PROJECT FINANCIAL RESOURCES i) Local In-kind Contributions $0 ii) Local Public Revenues $0 iii) Local Private Revenues iv) Other Public Revenues: $0 - ODOT/FHWA $0 - OEPA $0 - OWDA $850,000 - CDBG $0 - Other $0 SUBTOTAL $850,000 v) OPWC Funds: - Grant $400,000 - Loan $400,000 SUBTOTAL $800,000 TOTAL FINANCIAL RESOURCES $1,650,000 b) PROJECT ESTIMATED COSTS:

  • Information Systems The Official Agency in conjunction with the Authority will meet the relevant requirements of Articles 131 to 136 of Regulation (EU) 2017/625 and Implementing Regulation (EU) 2019/1715 as appropriate to the Official Agency. The Official Agency shall record appropriate data in the Official Agency Premises Inspection database (OAPI), which will be further developed over the life of the contract. Data should be entered into the database on an ongoing basis but shall be entered within one month of the activity taking place, unless otherwise agreed with the Authority.

  • Financial Management System Subrecipient shall establish and maintain a sound financial management system, based upon generally accepted accounting principles. Contractor’s system shall provide fiscal control and accounting procedures that will include the following:

  • Mineral Reserves and Resources The most recent estimated, proven and probable mineral reserves and the estimated measured, indicated and inferred mineral resources of Yamana disclosed in Yamana Documents have been prepared and disclosed in all material respects in accordance with all applicable Laws. There has been no material reduction (other than as a result of operations in the ordinary course of business) in the aggregate amount of estimated mineral reserves and estimated mineral resources of Yamana on a consolidated basis from the amounts disclosed publicly by Yamana.

  • Services and Resources Services Contractor Agrees to Perform. Contractor agrees to perform the Services stated in Appendix A, “Scope of Services.” Officers and employees of the City are not authorized to request, and the City is not required to reimburse the Contractor for, Services beyond the Scope of Services listed in Appendix A, unless Appendix A is modified as provided in Section 11.5, “Modification of this Agreement.” Personnel

  • Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.

Time is Money Join Law Insider Premium to draft better contracts faster.