Utility Consumption Guarantees Sample Clauses

Utility Consumption Guarantees. Natural Gas Consumption: Maximum 36,000 BTU per gallon (average) of un-denatured fuel ethanol produced for gas-fired boiler and gas fired rotary drum dryer based on natural gas provided at a minimum gas quality of 939 BTU per standard cubic foot (1 atm, 70° F), 10% maximum (weight) DDGS moisture content, and minimum boiler thermal efficiency of 84%. This guarantee is only in effect if the plant design DOES include a DDGS dryer Process Electrical Consumption: Maximum 1.000 kWh per gallon (average) of un-denatured fuel ethanol produced when operating at the nameplate capacity based on electric service with 0.85 power factor. This number includes process equipment components in mash preparation, liquefaction, yeast mix and propagation, fermentation, distillation, dehydration and acid reduction, evaporation, separation and stillage, process condensate, chemical storage, CO2 scrubbing, compressed air, WDGS transfer and handling, ethanol storage and load-out, cooling tower including cooling water circulation, condensate return, process sumps, and heat tracing. The indicated consumption does not include grain receiving and storage, milling, boiler, chiller, RTO, water supply or treatment, and CO2 transmission or recovery. Process Steam Consumption: Maximum 24,000 actual steam BTUs per gallon (average) (without dryer) of un-denatured fuel ethanol produced (as calculated in Section 2.5 of Exhibit B). This number includes the steam to all process components. This guarantee is only in effect if the plant design does NOT include a DDGS dryer
AutoNDA by SimpleDocs

Related to Utility Consumption Guarantees

  • Maintenance Repairs Utility Installations Trade Fixtures and Alterations 7.1 Lessee's Obligations.

  • Tenant’s Maintenance Obligations Tenant shall (i) keep and maintain the Premises in good appearance, repair and condition and maintain proper janitorial services, (ii) promptly make all repairs (interior and exterior, structural and nonstructural, ordinary and extraordinary, foreseen and unforeseen) necessary to keep each Facility in good and lawful order and condition and in substantial compliance with all applicable requirements and laws relating to the business conducted thereon, including, if applicable certification for participation in Medicare and Medicaid, and (iii) keep and maintain all Landlord and Tenant Personal Property in good condition, ordinary wear and tear, casualty and condemnation excepted, and repair and replace such property consistent with prudent industry practice.

  • Electrical During the Term of this Lease, there shall be available to the Leased Premises electrical facilities comparable to those supplied in other comparable office buildings in the vicinity of the Building to provide sufficient power for normal lighting and office machines of similar low electrical consumption, and one personal computer for each desk station, but not for any additional computers or extraordinary data processing equipment, special lighting and any other item of electrical equipment which requires a voltage other than one hundred ten (110) volts single phase and is not typically found in an office, as determined by Landlord in its sole, but reasonable discretion; and provided, however, that if the installation of such electrical equipment requires additional air conditioning capacity above that normally provided to tenants of the Building or above standard usage of existing capacity as determined by Landlord in its sole, but reasonable discretion, then the additional air conditioning installation and/or operating costs attributable thereto shall be paid by Tenant. Tenant agrees not to use any apparatus or device in, upon or about the Leased Premises which may in any way increase the amount of such electricity usually furnished or supplied to the Leased Premises, and Tenant further agrees not to connect any apparatus or device to the wires, conduits or pipes or other means by which such electricity is supplied, for the purpose of using additional or unusual amounts of electricity, without the prior written consent of Landlord. At all times, Tenant’s use of electric current shall never exceed Tenant’s share of the capacity of the feeders to the Building or the risers or wiring installation. Tenant shall not install or use or permit the installation or use in the Leased Premises of any computer or electronic data processing or ancillary equipment or any other electrical apparatus designed to operate on electrical current in excess of 110 volts and 5 amps per machine, without the prior written consent of Landlord, which consent shall not be unreasonably withheld, conditioned or delayed. If Tenant shall require electrical current in excess of that usually furnished or supplied for use of the Leased Premises as general office space, Tenant shall first procure the written consent of Landlord (which consent shall not be unreasonably withheld, conditioned or delayed) to the use thereof and Landlord or Tenant may (i) cause a meter to be installed in or for the Leased Premises, or (ii) if Tenant elects not to install said meter, Landlord may reasonably estimate such excess electrical current. The cost of any meters (including, without limitation, the cost of any installation) or surveys to estimate such excess electrical current shall be paid by Tenant. Landlord’s approval of any space plan, floor plan, construction plans, specifications, or other drawings or materials regarding the construction of the Tenant Improvements or any alterations shall not be deemed or construed as consent by Landlord under this paragraph to Tenant’s use of such excess electrical current as provided above. Tenant agrees to pay to Landlord, promptly upon demand therefor, all costs of such excess electrical current consumed as calculated by said meters (at the rates charged for such services to the Building by the municipality or the local public utility) or the excess amount specified in said estimate, as the case may be, plus any additional expense incurred in keeping account of the electrical current so consumed, which additional expense Landlord shall advise Tenant within a reasonable time after request by Tenant.

  • Access to Facilities Each of the Company and each of its Subsidiaries will permit any representatives designated by the Purchaser (or any successor of the Purchaser), upon reasonable notice and during normal business hours, at such person's expense and accompanied by a representative of the Company, to:

  • Utility Charges Tenant shall pay or cause to be paid all charges for electricity, power, gas, oil, water and other utilities used in connection with the Leased Property.

  • Furniture, Fixtures and Equipment Sublessee shall have the right to use during the Term the office furnishings and equipment within the Subleased Premises that are identified on Exhibit C attached hereto, as such exhibit may be adjusted by mutual agreement of the parties prior to the Third Floor Premises Delivery Date (the “Furniture”), provided Sublessee may only use the Furniture located in the Second Floor Premises after the Second Floor Commencement Date. The Furniture is provided in its “AS IS, WHERE IS” condition, without representation or warranty whatsoever. Sublessee shall insure the Furniture under the property insurance policy required under the Master Lease, as incorporated herein, and pay all taxes with respect to the Furniture. Sublessee shall maintain the Furniture in good condition and repair, reasonable wear and tear excepted, and shall be responsible for any loss or damage to the same occurring during the Term. Sublessee shall surrender the Furniture to Sublessor upon the termination of this Sublease in the same condition as exists as of the applicable Delivery Date, reasonable wear and tear excepted. Sublessee shall not remove any of the Furniture from the Subleased Premises. Notwithstanding anything to the contrary herein, Sublessee may provide Sublessor with written notice one (1) time not less than forty-five (45) days prior to the Third Floor Premises Delivery Date that lists any items of Furniture that Sublessee does not want to use and Sublessor shall, at no cost to Sublessee, remove such items from the Subleased Premises prior to the Third Floor Premises Delivery Date and such items shall no longer be considered Furniture hereunder. Notwithstanding the foregoing, provided Sublessee is not in default beyond the expiration of any applicable cure or grace period as of the date of the expiration or earlier termination of this Sublease, which condition may be waived by Sublessor in its sole discretion, then upon the expiration or earlier termination of this Sublease, the Furniture shall become the property of Sublessee, and Sublessee shall accept the same in its “AS IS, WHERE IS” condition, without representation or warranty whatsoever except as provided in the Bill of Sale referred to in the following sentence. In the event the Furniture is to become the property of Sublessee upon the expiration or earlier termination of this Sublease pursuant to the terms of the immediately preceding sentence, then Sublessor agrees to execute and deliver to Sublessee a Bill of Sale in the form of Exhibit D attached hereto conveying and transferring to Sublessee the Furniture.

  • Utilities Lessee shall pay for all water, gas, heat, light, power, telephone, trash disposal and other utilities and services supplied to the Premises, together with any taxes thereon. If any such services are not separately metered to Lessee, Lessee shall pay a reasonable proportion, to be determined by Lessor, of all charges jointly metered.

  • Operation and Maintenance of Properties The Borrower, at its own expense, will, and will cause each Subsidiary to:

  • TENANT’S MAINTENANCE AND REPAIR Tenant at its sole expense shall comply with all applicable laws and governmental regulations governing the Premises and make all repairs necessary to keep the Premises in the condition as existed on the Commencement Date (or on any later date that the improvements may have been installed), excepting ordinary wear and tear, including without limitation the electrical and mechanical systems, any air conditioning, ventilating or heating equipment which serves the Premises, all walls, glass, windows, doors, door closures, hardware, fixtures, electrical, plumbing, fire extinguisher equipment and other equipment. Any damage or deterioration of the Premises shall not be deemed ordinary wear and tear if the same could have been prevented by good maintenance practices by Tenant. As part of its maintenance obligations hereunder, Tenant shall, at Landlord’s request, provide Landlord with copies of all maintenance schedules, reports and notices prepared by, for or on behalf of Tenant. Tenant shall obtain preventive maintenance contracts from a licensed heating and air conditioning contractor to provide for regular inspection and maintenance of the heating, ventilating and air conditioning systems servicing the Premises, all subject to Landlord’s approval. All repairs shall be at least equal in quality to the original work, shall be made only by a licensed contractor approved in writing in advance by Landlord (which approval shall not be unreasonably withheld), and shall be made only at the time or times approved by Landlord. Any contractor utilized by Tenant shall be subject to Landlord’s standard requirements for contractors, as modified from time to time. Landlord shall have the right at all times (upon at least 24 hours’ prior notice) to inspect Tenant’s maintenance of all equipment (including without limitation air conditioning, ventilating and heating equipment), and may impose reasonable restrictions and requirements with respect to repairs, as provided in Section 7.3, and the provisions of Section 7.4 shall apply to all repairs. Alternatively, Landlord may elect to make any repair or maintenance required hereunder on behalf of Tenant and at Tenant’s expense, and Tenant shall promptly reimburse Landlord for all costs incurred upon submission of an invoice. Notwithstanding anything to the contrary contained in this Section 7.1, in the event Tenant’s obligation for compliance with all applicable laws and governmental regulations, or making repairs, results in a capital improvement on Tenant’s part (or Tenant’s being obligated to reimburse Landlord for a capital improvement), Tenant shall only be responsible for the amortized cost of such capital improvement (amortized at a market cost of funds as reasonably determined by Landlord) over the useful life of such improvements during the Term (except in the event obligation for any such capital improvement is required due to Tenant’s particular use of the Premises, in which case Tenant shall be fully responsible for the entire cost and installation of such capital improvement).

  • Maintenance of Facilities Each Borrower and FSI shall keep and cause each of FSI's Subsidiaries, including, without limitation, TEC AcquiSub, to keep, all of their respective Properties which are useful or necessary to such Borrower's, FSI's or such Subsidiary's business, in good repair and condition, normal wear and tear excepted, and from time to time make, and cause each such Subsidiary to make necessary repairs thereto, and renewals and replacements thereof so that each Borrower's, FSI's or such Subsidiary's Properties shall be fully and efficiently preserved and maintained.

Time is Money Join Law Insider Premium to draft better contracts faster.