Sub Station Switch Yard Lighting Sample Clauses

Sub Station Switch Yard Lighting. 24.1 FOAM TYPE-9 LTRS NOS 5 24.2 DRY CHEMICAL POWDER(TROLLEY MOUNTED)- 22.5 KGS NOS 6 24.3 DRY POWDER TYPE - 5 KGS NOS 6 24.4 CO2 - 4.5 KGS NOS 6 24.5 CO2 - 9 KGS NOS 6 24.6 CO2 (TROLLY MOUNTED)- 22.5 KGS NOS 4 24.7 9 litre Water type Nos. 4 24.8 50 Litres Mechanical Foam type Nos. 2 24.9 FIRE BUCKET (6 NOS IN EACH STAND) WITH STAND SET 5 25 SUBSTATION AUTOMATION SYSTEM FOR 220/132/33 KV SUBSTATION ON PRP MODE: Design , engineering , drawing, supervision, installation , testing & commissioning of Substation Automation system alongwith Supply of the following 220, 132 and 33 kV level of protection panels consisting of Bay control Units & numerical protection relays and other auxiliary relays suitable for SAS as per technical specification. (220KV side: COMPRISING OF 04 Nos. FEEDER BAYS + 02 TRANSFORMER BAYS + 01 Nos BUS COUPLER BAY, 132 KV side: COMPRISING OF 02 Nos. FEEDER SAYS + 04 Nos TRANSFORMER BAYS(auto & power trf.) + 01 No. BUS COUPLER BAY) & 33 KV side: COMPRISING OF 02 Nos. FEEDER SAYS + 05 Nos TRANSFORMER BAYS + 01 No. BUS COUPLER BAY) NOTE: All protective relays & BCU shall be numerical type.
AutoNDA by SimpleDocs
Sub Station Switch Yard Lighting. 23.1 FOAM TYPE-9 LTRS NOS 5 23.2 DRY CHEMICAL POWDER(TROLLEY MOUNTED)- 22.5 KGS NOS 6 23.3 DRY POWDER TYPE - 5 KGS NOS 6 23.4 CO2 - 4.5 KGS NOS 6 23.5 CO2 - 9 KGS NOS 6 23.6 CO2 (TROLLY MOUNTED)- 22.5 KGS NOS 4 23.7 9 litre Water type Nos. 4 23.8 50 Litres Mechanical Foam type Nos. 2
Sub Station Switch Yard Lighting. IT INCLUDES SUPPLY OF FIXTURES & LAMPS (LED) of reputed make (Philips/CGL/Bajaj) with switch gear,GI Conduit etc.(Lighting fixtures are to be fixed rigidly on the Column at a suitable height so that the required lux can be achieved).(150 watt each) SET 46
Sub Station Switch Yard Lighting 

Related to Sub Station Switch Yard Lighting

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Moonlighting 24.01 The Company and the Union agree in principle to eliminate the practice commonly referred to as moonlighting.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and ICG, ICG shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks, and the Entrance Facility on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from CBB to Verizon, CBB, at CBB’s own expense, shall:

  • Heating, Ventilating and Air Conditioning General Office Area: The building shall be equipped with a combination heating, ventilation and air conditioning system. The system shall have ducted supply and return air. The space above the ceiling shall not be used as a supply or return plenum. The systems shall be sized in accordance with the weather conditions identified in Chapter 13, “Energy Conservation” of the 1996 BOCA Building Code and supplemented by the “Building Code Rules”. All HVAC equipment shall be commercial or light industrial grade. If new construction it shall be installed at grade or within mechanical rooms for easy access and maintenance. If existing construction, roof mounted equipment will be considered after all other options have been exhausted, including the elimination of noise and vibration transfer to the structural members. The HVAC systems shall be zoned, with units sized and placed as required by heating and cooling loads on the building. Zoning of systems is dependent on the size, shape and orientation of the building. The HVAC system shall be divided into a minimum of 4 exterior and 1 interior temperature control zones. Return air shall be taken from the area supplied or adjacent to the area in the same temperature control zone. The ventilation and exhaust system shall be sized to maintain a positive pressure throughout the building envelope to limit air and dust infiltration. No HVAC ductwork shall be installed under the floor slab or underground.

  • Sub-loop Elements 2.8.1 Where facilities permit, BellSouth shall offer access to its Unbundled Sub-Loop (USL) elements as specified herein.

  • Dark Fiber Transport Dark Fiber Transport is defined as Dedicated Transport that consists of unactivated optical interoffice transmission facilities without attached signal regeneration, multiplexing, aggregation or other electronics. Except as set forth in Section 6.9.1 below, BellSouth shall not be required to provide access to Dark Fiber Transport Entrance Facilities pursuant to this Agreement.

  • Generators Temporary installation of generators, and permanent installation of generators that are placed inside existing non-residential buildings or that occupy an area under 50 square feet behind the building they serve.

Time is Money Join Law Insider Premium to draft better contracts faster.