Power Consumption. The Building Management at B sites may be concerned about the power consumption of the WinStar equipment installed on their premises. By using Chart N, it is possible to evaluate the amount of AC power that will be used by various equipment configurations. To use the chart it is first necessary to calculate the DC requirement of the WinStar equipment - this will typically be 1.5 amps for each IDU/ODU and 0.6 amps for each Mux. Using this figure, the monthly AC power consumption can be found from the chart. The chart uses figures taken from the Lorain MZ10F50 Technical Document and assumes a 730 hour month. EQUIPPED B SITE GUIDELINES This phase of the B Site process will define the criteria for a fully equipped B Site Installation. EQUIPMENT STANDARD B SITE EQUIPMENT ORDERING FORMS Central Office Implementation updates the master equipment ordering forms and provides approved copies to construction and logistics to standardize equipment ordering. The following is an approved B Site equipment ordering form. Current Electronic Copies are available from Logistics and Central Office Implementation Standard Configuration 1 Build P-COM 8xT1 Link Power PART# MFG QTY ----------------------------------------------------------------------------------------------------- Rectifier, 10 Amp 486524401 Reltec 2 ----------------------------------------------------------------------------------------------------- Fan Module, Rectifier 427215600 Reltec 2 ----------------------------------------------------------------------------------------------------- Mounting Cabinet, Rectifier 588242000 Reltec 1 ----------------------------------------------------------------------------------------------------- Battery, 12V 100 Amp Sure Power 4 ----------------------------------------------------------------------------------------------------- Shelf, Battery 412805200 Reltec 1 ----------------------------------------------------------------------------------------------------- Power Strip IBAR-12 Tripplite 1 ----------------------------------------------------------------------------------------------------- Fuse Panel, Alarm 19"-23" ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Mounts ----------------------------------------------------------------------------------------------------- Mounts: (one of following) 1 ----------------------------------------------------------------------------------------------------- Non-Penetrating Roof PSH-4 ▇▇▇▇▇ ----------------------------------------------------------------------------------------------------- Wall 60" 91148 Microflect ----------------------------------------------------------------------------------------------------- Wall 100" 91147 Microflect ----------------------------------------------------------------------------------------------------- Tripod, Penetrating Microflect ----------------------------------------------------------------------------------------------------- Cable Feet ----------------------------------------------------------------------------------------------------- RG-8 Plenum (feet) C-0216 5K ----------------------------------------------------------------------------------------------------- Octopus, 10' 5006-10 2 ----------------------------------------------------------------------------------------------------- IDU External Alarms 5016-08 1 ----------------------------------------------------------------------------------------------------- 16 awg 2 pair (feet) 9080-RED/BLK 20ft ----------------------------------------------------------------------------------------------------- DC Pwr 6 awg Red (feet) 0601-THHN-RED 10 ----------------------------------------------------------------------------------------------------- DC Pwr 6 awg Blk (feet) 0601-THHN-BLK 10 ----------------------------------------------------------------------------------------------------- Fuse Panel Alarm (feet) 9501 20 ----------------------------------------------------------------------------------------------------- Rectifier Alarm (feet) 20 ----------------------------------------------------------------------------------------------------- Mux Alarm (feet) 20 ----------------------------------------------------------------------------------------------------- 25 pr STP cable 24awg CMP-025-24-SSP ANIX 100 ----------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------- Cabinets ----------------------------------------------------------------------------------------------------- Indoor Enclosure GL 8401/32 Great Lakes 1 ----------------------------------------------------------------------------------------------------- Radio Equipment ----------------------------------------------------------------------------------------------------- IDU, 8x 16488 PCom 1 ----------------------------------------------------------------------------------------------------- ODU (one of following) ----------------------------------------------------------------------------------------------------- Band 1 16268 PCom ------------------------------------------------------------------------------------------------------ Band 2 16260 PCom ----------------------------------------------------------------------------------------------------- Band 3 16266 PCom ----------------------------------------------------------------------------------------------------- Band 4 16258 PCom ----------------------------------------------------------------------------------------------------- Antenna, 12" 23770-002 ▇▇▇▇▇▇▇ 1 ----------------------------------------------------------------------------------------------------- Power PART# MFG QTY ----------------------------------------------------------------------------------------------------- DSX ----------------------------------------------------------------------------------------------------- DSX-1 Panel, ▇▇▇▇ Field MINI DSX-1/W ADC 1 ----------------------------------------------------------------------------------------------------- DSX-1 Module MINI DSX-1/WM ADC 1 ----------------------------------------------------------------------------------------------------- Mounting Panel, DSX-3 3 Position ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Chassis, DSX-3/4 16 Position ▇▇▇▇▇▇▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Module, DSX-3/4 1090010401 Telect 1 ----------------------------------------------------------------------------------------------------- Local Termination Field ----------------------------------------------------------------------------------------------------- Split 50 pair block 6639-01-001-01 Krone 4 ----------------------------------------------------------------------------------------------------- Stand off bracket S89D ▇▇▇▇▇▇▇ 4 ----------------------------------------------------------------------------------------------------- Wire management rings 4 ----------------------------------------------------------------------------------------------------- 19" wall/cabinet mount Krone ----------------------------------------------------------------------------------------------------- Miscellaneous ----------------------------------------------------------------------------------------------------- Connector, RG-8 Plenum NS 5848-5 20 ----------------------------------------------------------------------------------------------------- Cable Standoff 10001-01 20 ----------------------------------------------------------------------------------------------------- Lightning Protection Device RT-N/W 5 ----------------------------------------------------------------------------------------------------- Ground Bar 40280013 1 ----------------------------------------------------------------------------------------------------- Mounting Bar, 19" 76017 1 ----------------------------------------------------------------------------------------------------- ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ----------------------------------------------------------------------------------------------------- ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ----------------------------------------------------------------------------------------------------- Screws 2 ----------------------------------------------------------------------------------------------------- Nut, Star Locking (6/32) 2 ----------------------------------------------------------------------------------------------------- Terminal, 12 Position N70149 BEAU 1 Standard Configuration 1 Build P-COM DS-3 Link Power PART# MFG QTY ------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------ Rectifier, 10 Amp 486524401 Reltec 2 ------------------------------------------------------------------------------------------ Fan Module, Rectifier 427215600 Reltec 2 ------------------------------------------------------------------------------------------ Mounting Cabinet, Rectifier 588242000 Reltec 1 ------------------------------------------------------------------------------------------ Battery, 12V 100 Amp Sure Power 4 ------------------------------------------------------------------------------------------ Shelf, Battery 412805200 Reltec 1 ------------------------------------------------------------------------------------------ Power Strip IBAR-12 Tripplite 1 ------------------------------------------------------------------------------------------ Fuse Panel, Alarm 19"-23" ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Mounts ------------------------------------------------------------------------------------------ Mounts: (one of following) 1 ------------------------------------------------------------------------------------------ Non-Penetrating Roof PSH-4 ▇▇▇▇▇ ------------------------------------------------------------------------------------------ Wall 60" 91148 Microflect ------------------------------------------------------------------------------------------ Wall 100" 91147 Microflect ------------------------------------------------------------------------------------------ Tripod, Penetrating Microflect ------------------------------------------------------------------------------------------ Cable Feet ------------------------------------------------------------------------------------------ RG-8 Plenum (feet) C-0216 5K ------------------------------------------------------------------------------------------ Octopus, 10' 5006-10 2 ------------------------------------------------------------------------------------------ IDU External Alarms 5016-08 1 ------------------------------------------------------------------------------------------ 16 awg 2 pair (feet) 9080-RED/BLK 20ft ------------------------------------------------------------------------------------------ DC Pwr 6 awg Red (feet) 0601-THHN-RED 10 ------------------------------------------------------------------------------------------ DC Pwr 6 awg Blk (feet) 0601-THHN-BLK 10 ------------------------------------------------------------------------------------------ Fuse Panel Alarm (feet) 9501 20 ------------------------------------------------------------------------------------------ Rectifier Alarm (feet) 20 ------------------------------------------------------------------------------------------ Mux Alarm (feet) 20 ------------------------------------------------------------------------------------------ 25 pr STP cable 24awg 100 ------------------------------------------------------------------------------------------ Muxes ------------------------------------------------------------------------------------------ Mux, M13 NEC RC-28D NEC ------------------------------------------------------------------------------------------ Cabinets ------------------------------------------------------------------------------------------ Indoor Enclosure GL 8401/32 Great Lakes 1 ------------------------------------------------------------------------------------------ Radio Equipment ------------------------------------------------------------------------------------------ IDU, 8x 16488 PCom 1 ------------------------------------------------------------------------------------------ ODU (one of following) ------------------------------------------------------------------------------------------ Band 1 16268 PCom ------------------------------------------------------------------------------------------ Band 2 16260 PCom ------------------------------------------------------------------------------------------ Band 3 16266 PCom ------------------------------------------------------------------------------------------ Band 4 16258 PCom ------------------------------------------------------------------------------------------ Antenna, 12" 23770-002 ▇▇▇▇▇▇▇ 1 ------------------------------------------------------------------------------------------ Power PART# MFG QTY ------------------------------------------------------------------------------------------ DSX ------------------------------------------------------------------------------------------ DSX-1 Panel, ▇▇▇▇ Field MINI DSX-1/W ADC 1 ------------------------------------------------------------------------------------------ DSX-1 Module MINI DSX-1/WM ADC 1 ------------------------------------------------------------------------------------------ Mounting Panel, DSX-3 3 Position ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Chassis, DSX-3/4 16 Position ▇▇▇▇▇▇▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Module, DSX-3/4 1090010401 Telect 1 ------------------------------------------------------------------------------------------ Local Termination Field ------------------------------------------------------------------------------------------ Split 50 pair block 6639-01-001-01 Krone 4 ------------------------------------------------------------------------------------------ Stand off bracket S89D ▇▇▇▇▇▇▇ 4 ------------------------------------------------------------------------------------------ Wire management rings 4 ------------------------------------------------------------------------------------------ 19" wall/cabinet mount Krone ------------------------------------------------------------------------------------------ Miscellaneous ------------------------------------------------------------------------------------------ Connector, RG-8 Plenum NS 5848-5 bulk ------------------------------------------------------------------------------------------ Cable Standoff 10001-01 20 ------------------------------------------------------------------------------------------ Lightning Protection Device RT-N/W bulk ------------------------------------------------------------------------------------------ Ground Bar 40280013 1 ------------------------------------------------------------------------------------------ Mounting Bar, 19" 76017 1 ------------------------------------------------------------------------------------------ ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ------------------------------------------------------------------------------------------ ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ------------------------------------------------------------------------------------------ Screws 2 ------------------------------------------------------------------------------------------ Nut, Star Locking (6/32) 2 ------------------------------------------------------------------------------------------ ▇▇▇▇▇▇▇▇, ▇▇ ▇▇▇▇▇▇▇▇ ▇▇ ▇▇▇▇▇ BEAU 1 On-Net (B-site) equipment shall be pre-assembled and tested prior to deployment in the field. STANDARDIZED B-SITE EQUIPMENT CONFIGURATIONS o DS1-1 8XT1 IDU o DS1-2 8XT1 IDU WIRING o DS1-3 8XT1 IDU ALARM WIRING o DS3-1 8XT1 IDU o DS3-2 8XT1 IDU WIRING o DS3-3 8XT1 IDU ALARM WIRING o B-SITE ANTENNA SURGE PROTECTION LOCAL TERMINATION FIELD AND CIRCUIT DEMARC (See Appendix f
Appears in 2 contracts
Sources: Wireless Fiber Iru Agreement (Winstar Communications Inc), Wireless Fiber Iru Agreement (Winstar Communications Inc)
Power Consumption. The Building Management at B sites may be concerned about the power consumption of the WinStar equipment installed on their premises. By using Chart N, it is possible to evaluate the amount of AC power that will be used by various equipment configurations. To use the chart it is first necessary to calculate the DC requirement of the WinStar equipment - this will typically be 1.5 amps for each IDU/ODU and 0.6 amps for each Mux. Using this figure, the monthly AC power consumption can be found from the chart. The chart uses figures taken from the Lorain MZ10F50 Technical Document and assumes a 730 hour month. EQUIPPED B SITE GUIDELINES This phase of the B Site process will define the criteria for a fully equipped B Site Installation. EQUIPMENT STANDARD B SITE EQUIPMENT ORDERING FORMS Central Office Implementation updates the master equipment ordering forms and provides approved copies to construction and logistics to standardize equipment ordering. The following is an approved B Site equipment ordering form. Current Electronic Copies are available from Logistics and Central Office Implementation Standard Configuration 1 Build P-COM 8xT1 Link Power PART# MFG QTY ----------------------------------------------------------------------------------------------------- Rectifier, 10 Amp 486524401 Reltec 2 ----------------------------------------------------------------------------------------------------- Fan Module, Rectifier 427215600 Reltec 2 ----------------------------------------------------------------------------------------------------- Mounting Cabinet, Rectifier 588242000 Reltec 1 ----------------------------------------------------------------------------------------------------- Battery, 12V 100 Amp Sure Power 4 ----------------------------------------------------------------------------------------------------- Shelf, Battery 412805200 Reltec 1 ----------------------------------------------------------------------------------------------------- Power Strip IBAR-12 Tripplite 1 ----------------------------------------------------------------------------------------------------- Fuse Panel, Alarm 19"-23" ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Mounts ----------------------------------------------------------------------------------------------------- Mounts: (one of following) 1 ----------------------------------------------------------------------------------------------------- Non-Penetrating Roof PSH-4 ▇▇▇▇▇ ----------------------------------------------------------------------------------------------------- Wall 60" 91148 Microflect ----------------------------------------------------------------------------------------------------- Wall 100" 91147 Microflect ----------------------------------------------------------------------------------------------------- Tripod, Penetrating Microflect ----------------------------------------------------------------------------------------------------- Cable Feet ----------------------------------------------------------------------------------------------------- RG-8 Plenum (feet) C-0216 5K ----------------------------------------------------------------------------------------------------- Octopus, 10' 5006-10 2 ----------------------------------------------------------------------------------------------------- IDU External Alarms 5016-08 1 ----------------------------------------------------------------------------------------------------- 16 awg 2 pair (feet) 9080-RED/BLK 20ft ----------------------------------------------------------------------------------------------------- DC Pwr 6 awg Red (feet) 0601-THHN-RED 10 ----------------------------------------------------------------------------------------------------- DC Pwr 6 awg Blk (feet) 0601-THHN-BLK 10 ----------------------------------------------------------------------------------------------------- Fuse Panel Alarm (feet) 9501 20 ----------------------------------------------------------------------------------------------------- Rectifier Alarm (feet) 20 ----------------------------------------------------------------------------------------------------- Mux Alarm (feet) 20 ----------------------------------------------------------------------------------------------------- 25 pr STP cable 24awg CMP-025-24-SSP ANIX 100 ----------------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------- Cabinets ----------------------------------------------------------------------------------------------------- Indoor Enclosure GL 8401/32 Great Lakes 1 ----------------------------------------------------------------------------------------------------- Radio Equipment ----------------------------------------------------------------------------------------------------- IDU, 8x 16488 PCom 1 ----------------------------------------------------------------------------------------------------- ODU (one of following) ----------------------------------------------------------------------------------------------------- Band 1 16268 PCom ------------------------------------------------------------------------------------------------------ Band 2 16260 PCom ----------------------------------------------------------------------------------------------------- Band 3 16266 PCom ----------------------------------------------------------------------------------------------------- Band 4 16258 PCom ----------------------------------------------------------------------------------------------------- Antenna, 12" 23770-002 ▇▇▇▇▇▇▇ 1 ----------------------------------------------------------------------------------------------------- Power PART# MFG QTY ----------------------------------------------------------------------------------------------------- DSX ----------------------------------------------------------------------------------------------------- DSX-1 Panel, ▇▇▇▇ Field MINI DSX-1/W ADC 1 ----------------------------------------------------------------------------------------------------- DSX-1 Module MINI DSX-1/WM ADC 1 ----------------------------------------------------------------------------------------------------- Mounting Panel, DSX-3 3 Position ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Chassis, DSX-3/4 16 Position ▇▇▇▇▇▇▇▇▇▇ Telect 1 ----------------------------------------------------------------------------------------------------- Module, DSX-3/4 1090010401 Telect 1 ----------------------------------------------------------------------------------------------------- Local Termination Field ----------------------------------------------------------------------------------------------------- Split 50 pair block 6639-01-001-01 Krone 4 ----------------------------------------------------------------------------------------------------- Stand off bracket S89D ▇▇▇▇▇▇▇ 4 ----------------------------------------------------------------------------------------------------- Wire management rings 4 ----------------------------------------------------------------------------------------------------- 19" wall/cabinet mount Krone ----------------------------------------------------------------------------------------------------- Miscellaneous ----------------------------------------------------------------------------------------------------- Connector, RG-8 Plenum NS 5848-5 20 ----------------------------------------------------------------------------------------------------- Cable Standoff 10001-01 20 ----------------------------------------------------------------------------------------------------- Lightning Protection Device RT-N/W 5 ----------------------------------------------------------------------------------------------------- Ground Bar 40280013 1 ----------------------------------------------------------------------------------------------------- Mounting Bar, 19" 76017 1 ----------------------------------------------------------------------------------------------------- ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ----------------------------------------------------------------------------------------------------- ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ----------------------------------------------------------------------------------------------------- Screws 2 ----------------------------------------------------------------------------------------------------- Nut, Star Locking (6/32) 2 ----------------------------------------------------------------------------------------------------- Terminal, 12 Position N70149 BEAU 1 Standard Configuration 1 Build P-COM DS-3 Link Power PART# MFG QTY ------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------ Rectifier, 10 Amp 486524401 Reltec 2 ------------------------------------------------------------------------------------------ Fan Module, Rectifier 427215600 Reltec 2 ------------------------------------------------------------------------------------------ Mounting Cabinet, Rectifier 588242000 Reltec 1 ------------------------------------------------------------------------------------------ Battery, 12V 100 Amp Sure Power 4 ------------------------------------------------------------------------------------------ Shelf, Battery 412805200 Reltec 1 ------------------------------------------------------------------------------------------ Power Strip IBAR-12 Tripplite 1 ------------------------------------------------------------------------------------------ Fuse Panel, Alarm 19"-23" ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Mounts ------------------------------------------------------------------------------------------ Mounts: (one of following) 1 ------------------------------------------------------------------------------------------ Non-Penetrating Roof PSH-4 ▇▇▇▇▇ ------------------------------------------------------------------------------------------ Wall 60" 91148 Microflect ------------------------------------------------------------------------------------------ Wall 100" 91147 Microflect ------------------------------------------------------------------------------------------ Tripod, Penetrating Microflect ------------------------------------------------------------------------------------------ Cable Feet ------------------------------------------------------------------------------------------ RG-8 Plenum (feet) C-0216 5K ------------------------------------------------------------------------------------------ Octopus, 10' 5006-10 2 ------------------------------------------------------------------------------------------ IDU External Alarms 5016-08 1 ------------------------------------------------------------------------------------------ 16 awg 2 pair (feet) 9080-RED/BLK 20ft ------------------------------------------------------------------------------------------ DC Pwr 6 awg Red (feet) 0601-THHN-RED 10 ------------------------------------------------------------------------------------------ DC Pwr 6 awg Blk (feet) 0601-THHN-BLK 10 ------------------------------------------------------------------------------------------ Fuse Panel Alarm (feet) 9501 20 ------------------------------------------------------------------------------------------ Rectifier Alarm (feet) 20 ------------------------------------------------------------------------------------------ Mux Alarm (feet) 20 ------------------------------------------------------------------------------------------ 25 pr STP cable 24awg 100 ------------------------------------------------------------------------------------------ Muxes ------------------------------------------------------------------------------------------ Mux, M13 NEC RC-28D NEC ------------------------------------------------------------------------------------------ Cabinets ------------------------------------------------------------------------------------------ Indoor Enclosure GL 8401/32 Great Lakes 1 ------------------------------------------------------------------------------------------ Radio Equipment ------------------------------------------------------------------------------------------ IDU, 8x 16488 PCom 1 ------------------------------------------------------------------------------------------ ODU (one of following) ------------------------------------------------------------------------------------------ Band 1 16268 PCom ------------------------------------------------------------------------------------------ Band 2 16260 PCom ------------------------------------------------------------------------------------------ Band 3 16266 PCom ------------------------------------------------------------------------------------------ Band 4 16258 PCom ------------------------------------------------------------------------------------------ Antenna, 12" 23770-002 ▇▇▇▇▇▇▇ 1 ------------------------------------------------------------------------------------------ Power PART# MFG QTY ------------------------------------------------------------------------------------------ DSX ------------------------------------------------------------------------------------------ DSX-1 Panel, ▇▇▇▇ Field MINI DSX-1/W ADC 1 ------------------------------------------------------------------------------------------ DSX-1 Module MINI DSX-1/WM ADC 1 ------------------------------------------------------------------------------------------ Mounting Panel, DSX-3 3 Position ▇▇▇-▇▇▇▇-▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Chassis, DSX-3/4 16 Position ▇▇▇▇▇▇▇▇▇▇ Telect 1 ------------------------------------------------------------------------------------------ Module, DSX-3/4 1090010401 Telect 1 ------------------------------------------------------------------------------------------ Local Termination Field ------------------------------------------------------------------------------------------ Split 50 pair block 6639-01-001-01 Krone 4 ------------------------------------------------------------------------------------------ Stand off bracket S89D ▇▇▇▇▇▇▇ 4 ------------------------------------------------------------------------------------------ Wire management rings 4 ------------------------------------------------------------------------------------------ 19" wall/cabinet mount Krone ------------------------------------------------------------------------------------------ Miscellaneous ------------------------------------------------------------------------------------------ Connector, RG-8 Plenum NS 5848-5 bulk ------------------------------------------------------------------------------------------ Cable Standoff 10001-01 20 ------------------------------------------------------------------------------------------ Lightning Protection Device RT-N/W bulk ------------------------------------------------------------------------------------------ Ground Bar 40280013 1 ------------------------------------------------------------------------------------------ Mounting Bar, 19" 76017 1 ------------------------------------------------------------------------------------------ ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ------------------------------------------------------------------------------------------ ▇▇▇▇▇ ▇▇▇▇, ▇" ▇▇▇ ▇▇▇-▇▇▇▇-▇-▇ bulk ------------------------------------------------------------------------------------------ Screws 2 ------------------------------------------------------------------------------------------ Nut, Star Locking (6/32) 2 ------------------------------------------------------------------------------------------ ▇▇▇▇▇▇▇▇, ▇▇ ▇▇▇▇▇▇▇▇ ▇▇ ▇▇▇▇▇ BEAU 1 On-Net (B-site) equipment shall be pre-assembled and tested prior to deployment in the field. STANDARDIZED B-SITE EQUIPMENT CONFIGURATIONS o DS1-1 8XT1 IDU o DS1-2 8XT1 IDU WIRING o DS1-3 8XT1 IDU ALARM WIRING o DS3-1 8XT1 IDU o DS3-2 8XT1 IDU WIRING o DS3-3 8XT1 IDU ALARM WIRING o B-SITE ANTENNA SURGE PROTECTION LOCAL TERMINATION FIELD AND CIRCUIT DEMARC (See Appendix f------------------------------------------------------------------------------------------
Appears in 1 contract
Sources: Wireless Fibersm Iru Agreement (Winstar Communications Inc)