Plume visibilityDioxin Monitoring Sample Clauses

Plume visibilityDioxin Monitoring. The Tenderer shall include in his Proposal the Works and Services of complying with the following BATNEEC interpretation of condition 5(11) of the Planning Scheme Order: In the daytime, the plume from the stack must not be visible unless the humidity of the ambient air at the actual ambient air temperature is higher than indicated by the relative humidities of the following table. Daytime is defined as the time interval from half an hour before sunrise to half an hour after sunset. Relative humidity, %RH 29 42 53 63 71 78 84 88 92 95 97 98 99 100 For temperatures between the listed values, relative humidity limits are obtained by linear interpolation between adjacent points. No visible plume is allowed at ambient temperatures higher than 14°C. A visible plume is allowed at ambient temperatures lower than 1°C. A meteorological station for measurement of ambient temperature and relative humidity, including data logging and reporting facilities shall be included in the supply. This station shall be installed at the top of the chimneystack and the measurement of ambient temperature and relative humidity shall be continuously and easily accessible on the CMS System. The Facility should be designed and equipped so that, at any time, the operator can make the temperature and humidity of the flue gas leaving the stack fulfil the following condition, Temperature (°C) > 10 * water content (vol. %) – 5 In the daytime, whenever the plume is visible or there is a risk of the plume being visible, the Facility should be operated so that the condition is fulfilled (for the temperature and water content of the flue gas leaving the stack). The instrumentation and software needed to verify the fulfilment of the condition should be included in the supply. Complete supply of equipment, strategic spare parts, two spare probes, installation, commissioning, operation and maintenance related with continuous dioxin monitoring on both Primary and Secondary Waste streams is included in the Scope of Supply. The equipment shall be installed at the base of the stack and be fully integrated with the remaining plant parts (e.g. CMS and cooling water systems).7
AutoNDA by SimpleDocs

Related to Plume visibilityDioxin Monitoring

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Geometric visibility The visibility of the illuminating surface, including its visibility in areas which do not appear to be illuminated in the direction of observation considered, shall be ensured within a divergent space defined by generating lines based on the perimeter of the illuminating surface and forming an angle of not less than 5° with the axis of reference of the headlamp. The origin of the angles of geometric visibility is the perimeter of the projection of the illuminating surface on a transverse plane tangent to the foremost part of the lens of the headlamp.

  • System Monitoring to ensure safe and continuous operation, the Customer must monitor key services and resource use as recommended by Deswik, and provide Deswik with details of monitoring and any relevant alerts as needed. Services to be monitors include, without limitation, disk space, CPU usage, memory usage, database connectivity, and network utilization.

  • Supply Chain Monitoring A copy of the supply chain monitoring process, which should include details of the process for monitoring the financial viability of the supply chain (including timing), together with any known risks to supply chain stability and material changes to the supply chain. This should include extracts from Board level meetings, risk registers etc where any of the above items have been discussed. Annex 1 1 Information from Contractors who are not required to submit form AR01 to Companies House

  • Service Monitoring Customer gives express consent for Vodafone to monitor Customer’s use of the Service (and disclose and otherwise use the information obtained) only to: (a) the extent allowed by Applicable Law; (b) comply with Applicable Law; (c) protect the Network from misuse; (d) protect the integrity of the public internet and/or Vodafone’s systems and Networks; (e) the extent necessary to determine if Customer has breached any conditions or restrictions on use of the Service; (f) provide the Service; and/or (g) take other actions agreed or requested by Customer.

  • SERVICE MONITORING, ANALYSES AND ORACLE SOFTWARE 11.1 We continuously monitor the Services to facilitate Oracle’s operation of the Services; to help resolve Your service requests; to detect and address threats to the functionality, security, integrity, and availability of the Services as well as any content, data, or applications in the Services; and to detect and address illegal acts or violations of the Acceptable Use Policy. Oracle monitoring tools do not collect or store any of Your Content residing in the Services, except as needed for such purposes. Oracle does not monitor, and does not address issues with, non-Oracle software provided by You or any of Your Users that is stored in, or run on or through, the Services. Information collected by Oracle monitoring tools (excluding Your Content) may also be used to assist in managing Oracle’s product and service portfolio, to help Oracle address deficiencies in its product and service offerings, and for license management purposes.

  • Fire Fighting Costs of operating and maintaining the fire-fighting equipments and personnel, if any.

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

Time is Money Join Law Insider Premium to draft better contracts faster.