Physical, Mechanical, and Electrical Properties Sample Clauses

Physical, Mechanical, and Electrical Properties. The wire shall conform to the properties listed in Table 1. TABLE 1: Physical, Mechanical, and Electrical Properties #12 CCS 1055 Hard Drawn 21% Conductivity CCS Conductor Conductor Size 12 AWG Conductor Type Copper Clad Steel (CCS) Temper Hard Drawn (HD) Average Break Load 1150 lbs. Minimum Tensile Strength 200,000 psi Minimum Elongation 1.0% Copper Thickness (% of Diameter) 3.0% Minimum Copper Weight 13% Nominal DC Resistance (ohms/1000 ft.) 7.5648 *Diameter tolerances: ± 1%
AutoNDA by SimpleDocs
Physical, Mechanical, and Electrical Properties. The wire shall conform to the properties listed in Table 2. TABLE 2: Physical, Mechanical, and Electrical Properties High Density Polyethylene Insulator Value Density (ASTM D 792) 0.943 g/cc Bulk Density (ASTM D 1895) 0.58 g/cc Melt Index (ASTM D 1238/E) 0.70 dg/min Tensile-Yield (ASTM D 638) 4300 psi Tensile-Ultimate (ASTM D 638) 2900 psi Tensile-Elongation (ASTM D 638) 850% Flexural Modulas (ASTM D 790/1) 120,000 psi Hardness (ASTM D 2240) 63 Shore D Environmental Stress-Crack (ASTM D 1693/B) F20 > 48 h Thermal Stress-Crack (ASTM D2951) F0 > 1000 h Brittleness Temperature (ASTM D 746) < -95° F Melting Point (DSC) (ASTM D 3417) 262° F Softening Point (Vicat) (ASTM D 1525) 250° F Oxidative Induction Time (ASTM D 3895) > 50 min. @ 200° C Dielectric Constant (ASTM D 1531) 2.34 @ 1MHz Dissipation Factor (ASTM D 1531) 0.00007 @ 1 MHz Volume Resistivity (ASTM D 257) 5 x 1017 ohm-cm Dielectric Strength (ASTM D 3755) 1000 volts @ 20 mils END OF SECTION SECTION 15100 VALVES AND APPURTENANCES

Related to Physical, Mechanical, and Electrical Properties

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Electrical Power CUSTOMER acknowledges that the Services will not function in the absence of electrical power.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • Mechanical a. Heating and cooling load calculations as required and major duct or pipe runs sized to interface with structural.

  • Heating, Ventilation and Air Conditioning Landlord shall furnish to the Premises heating, ventilation and air-conditioning (“HVAC”) in accordance with the Design Standards set forth in Exhibit D during Ordinary Business Hours. Landlord shall have access to all air-cooling, fan, ventilating and machine rooms and electrical closets and all other mechanical installations of Landlord (collectively, “Mechanical Installations”), and Tenant shall not construct partitions or other obstructions which may interfere with Landlord’s access thereto or the moving of Landlord’s equipment to and from the Mechanical Installations. No Tenant Party shall at any time enter the Mechanical Installations or tamper with, adjust, or otherwise affect such Mechanical Installations. Landlord shall not be responsible if the HVAC System fails to provide cooled or heated air, as the case may be, to the Premises in accordance with the Design Standards by reason of (i) any equipment installed by, for or on behalf of Tenant, which has an electrical load in excess of the average electrical load and human occupancy factors for the HVAC System as designed, or (ii) any rearrangement of partitioning or other Alterations made or performed by, for or on behalf of Tenant. Tenant shall install, if missing, blinds or shades on all windows, which blinds and shades shall be subject to Landlord’s approval, and shall keep operable windows in the Premises closed, and lower the blinds when necessary because of the sun’s position, whenever the HVAC System is in operation or as and when required by any Requirement. Tenant shall cooperate with Landlord and shall abide by the rules and regulations which Landlord may reasonably prescribe for the proper functioning and protection of the HVAC System. Tenant acknowledges that the server room in the Premises currently has three heat pumps installed, being two 4-ton units, and one 2.5-ton unit (the “Existing Heat Pumps”). The 2.5-ton unit is currently connected and operational. Tenant shall determine whether it is satisfied with the condition of the Existing Heat Pumps and Landlord shall not have any responsibility or liability for the condition, operation, maintenance, repair or replacement of the Existing Heat Pumps. Tenant may operate the Existing Heat Pumps. Tenant shall be responsible for, and pay directly for, all necessary maintenance and repairs to the Existing Heat Pumps. Tenant shall reimburse Landlord monthly for the cost of all utility services used to operate the Existing Heat Pumps within 10 Business Days after receipt of Landlord’s invoice for such amount. Landlord may measure Tenant’s usage of such utility services by either a sub-meter or by other reasonable methods such as by temporary check meters or by survey. Tenant, at its cost, may replace the Existing Heat Pumps with one or more new heat pumps, provided, however, that the capacity of such replacement heat pump(s) shall not exceed the 10.5-ton capacity cooling capacity of the Existing Heat Pumps.

  • Inspection of Properties and Books Etc The Borrower shall permit the Lenders, through the Administrative Agent or any of the Lenders’ other designated representatives, no more frequently than once each calendar year, or more frequently as determined by the Lenders upon the occurrence and during the continuance of an Event of Default, to visit and inspect any of the properties of the Borrower or any of its Subsidiaries, and each such inspection, if no Event of Default has occurred and is continuing, shall be at the Lenders’ expense. The Borrower shall also permit the Lenders, through the Administrative Agent or any of the Lenders’ other designated representatives, to examine the books of account of the Borrower and its Subsidiaries (and to make copies thereof and extracts therefrom), and to discuss the affairs, finances and accounts of the Borrower and its Subsidiaries with, and to be advised as to the same by, its and their officers, all at such reasonable times and intervals as the Administrative Agent or any Lender may reasonably request. The Borrower authorizes the Administrative Agent and, if accompanied by the Administrative Agent, the Lenders to communicate directly with the Borrower’s independent certified public accountants and authorizes such accountants to disclose to the Administrative Agent and the Lenders any and all financial statements and other supporting financial documents and schedules with respect to the business, financial condition and other affairs of the Borrower or any of its Subsidiaries.

  • Records Maintenance; Access Contractor shall maintain all financial records relating to this Contract in accordance with generally accepted accounting principles. In addition, Contractor shall maintain any other records, books, documents, papers, plans, records of shipments and payments and writings of Contractor, whether in paper, electronic or other form, that are pertinent to this Contract (“Records”) in such a manner as to clearly document Contractor's performance. Contractor acknowledges and agrees that Agency and the Oregon Secretary of State's Office and the federal government and their duly authorized representatives will have access to such financial records and other Records that are pertinent to this Contract, whether in paper, electronic or other form, to perform examinations and audits and make excerpts and transcripts. Contractor shall retain and keep accessible all such financial records and other Records for a minimum of 6 years, or such longer period as may be required by applicable law, following final payment and termination of this Contract, or until the conclusion of any audit, controversy or litigation arising out of or related to this Contract, whichever date is later.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Systems The details of any systems work will be determined after a thorough business analysis. System's work will be billed on a time and material basis. Investors Bank provides an allowance of 10 systems hours for data extract set up and reporting extract set up. Additional hours will be billed on a time and material basis.

  • Plant The expression ‘Plant’ as used in the tender papers shall mean every temporary accessory necessary or considered necessary by the Engineer to execute, construct, complete and maintain the work and all altered, modified, substituted and additional works ordered in the time and the manner herein provided and all temporary materials and special and other articles and appliance of every sort kind and description whatsoever intended or used therefore.