Other CITY Street Sweeping Service Sample Clauses

Other CITY Street Sweeping Service. If during the term of this Agreement, 47 circumstances exist which require work associated with the Street Sweeping Service program 1 that are not specifically provided for in this Agreement, the City Representative may require 2 CONTRACTOR to perform such other associated work (OAW). When CONTRACTOR 3 performs OAW, the labor, materials, and equipment used in the performance of such work shall 4 be subject to the prior written approval of the City Representative. Examples of OAW that 5 CONTRACTOR may be required to perform include: performance of special sweeps, flood 6 clean-up, street sanitation for parades and celebrations, CITY requested clean-up services, and 7 any contingency where sweeper and supporting sweeper equipment could assist in a particular 8 instance.
AutoNDA by SimpleDocs

Related to Other CITY Street Sweeping Service

  • Water Service The Purchase Price for the Property shall include all water rights/water shares, if any, that are the legal source for Seller’s current culinary water service and irrigation water service, if any, to the Property. The water rights/water shares will be conveyed or otherwise transferred to Buyer at Closing by applicable deed or legal instruments. The following water rights/water shares, if applicable, are specifically excluded from this sale:

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • EMERGENCY SERVICE If you are unable to reach Administrator at 877.634.0964 and you require emergency repair, you may contact any manufacturer authorized service repair facility listed in Your phone book or online. Mail Administrator Your original repair bill along with the technician’s report and a copy of the Agreement to the address at the top of this Agreement for reimbursement. All coverage and exclusions in this Agreement will apply.

  • Outpatient emergency and urgicenter services within the service area The emergency room copay applies to all outpatient emergency visits that do not result in hospital admission within twenty-four (24) hours. The urgicenter copay is the same as the primary care clinic office visit copay.

  • Required Coverages For Generation Resources Of 20 Megawatts Or Less Each Constructing Entity shall maintain the types of insurance as described in section 11.1 paragraphs (a) through (e) above in an amount sufficient to insure against all reasonably foreseeable direct liabilities given the size and nature of the generating equipment being interconnected, the interconnection itself, and the characteristics of the system to which the interconnection is made. Additional insurance may be required by the Interconnection Customer, as a function of owning and operating a Generating Facility. All insurance shall be procured from insurance companies rated “A-,” VII or better by AM Best and authorized to do business in a state or states in which the Interconnection Facilities are located. Failure to maintain required insurance shall be a Breach of the Interconnection Construction Service Agreement.

  • – ORIENTATION AND IN SERVICE 20.01 An orientation and in service program will be provided to all employees. These programs shall be reviewed and discussed from time to time by members of the Union-Management Committee.

  • Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Fire Fighting Costs of operating and maintaining the fire-fighting equipments and personnel, if any.

  • Orientation and In-Service Program The Hospital recognizes the need for a Hospital Orientation Program of such duration as it may deem appropriate taking into consideration the needs of the Hospital and the nurses involved.

Time is Money Join Law Insider Premium to draft better contracts faster.