Monitoring, General Overview Sample Clauses

Monitoring, General Overview. This section describes the memory map used to access measurements of transceiver temperature, receive optical power, laser output power, and laser bias current through the 2 wire serial MDIO/MDC interface. These measurements are optional, and support is indicated through the capability registers (807A: DOM Capability and A06F: DOM Capability - Extended). The transceiver generates this monitoring data by digitization of internal analog signals. The digitized data is calibrated to absolute measurements that should be interpreted according to the sections below. Calibrated alarm and warning threshold data should be interpreted in the same manner and is written during device manufacture. Optional alarm/warning flags may be implemented for monitored quantities. Alarm flags are required if Digital Optical Monitoring (DOM) indicators are to be made inputs to the Link Alarm Status Interrupt (LASI) function. Measured parameters are reported in 16 bit data fields (i.e. two concatenated bytes). The 16 bit data fields allow for wide dynamic range, and are not intended to imply that a 16 bit A/D system is recommended or required in order to achieve the accuracy goals stated below. It is recommended that any low-order data bits beyond the system’s specified accuracy be fixed to zero. The update of the multi-byte fields (i.e. two concatenated bytes) must not occur such that partially updated multi-byte fields are read over the MDIO interface.
AutoNDA by SimpleDocs

Related to Monitoring, General Overview

  • General Overview This is an SLA between the Customer and UNM IT to document the provision of:  The Department Web Hosting service;  The general levels of response, availability, and maintenance associated with these services;  The responsibilities of UNM IT as a provider of these services;  The responsibilities of the Customers and Web Admins and Developers (Users) receiving these service;  The financial arrangements associated with the service. This SLA shall be effective as of the Effective Date set forth on the cover page and will continue until revised or terminated.

  • MONITORING OF OPERATION AND MAINTENANCE 19.1 Monthly status reports During Operation Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Independent Engineer a monthly report stating in reasonable detail the condition of the Bus Terminal including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the Independent Engineer. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.

  • MONITORING OF CONSTRUCTION 13.1 Monthly progress reports During the Construction Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Independent Engineer a monthly report on progress of the Construction Works and shall promptly give such other relevant information as may be required by the Independent Engineer.

  • LOT OVERVIEW This Contract encompasses the Lots listed in Appendix D – Contractor and Reseller Information. The following descriptions, as applicable, delineate the scope of the awarded Lots.

  • Monitoring Plan keep up with the objectives from the cadetship practice booklet; taking daily notes as well as learning new information every day; currently reporting to the supervisor. Evaluation plan: the final result should be in accordance with the traineeship’s aims and objectives, achieving an improvement of specialty knowledge and language skills. The level of language competence9 in English that the trainee already has or agrees to acquire by the start of the mobility period is: A1 ☐ A2 ☐ B1 ☐ B2 ☒ C1 ☐ C2 ☐ Native speaker ☐ Table B - Sending Institution Please use only one of the following three boxes: 10 The traineeship is embedded in the curriculum and upon satisfactory completion of the traineeship, the institution undertakes to:Award ……...…ECTS credits (or equivalent)11 Give a grade based on: Traineeship certificate ☒ Final report ☒ Interview ☐ Record the traineeship in the trainee's Transcript of Records and Diploma Supplement (or equivalent). Record the traineeship in the trainee's Europass Mobility Document: Yes ☒ No ☐ The traineeship is voluntary and, upon satisfactory completion of the traineeship, the institution undertakes to: Award ECTS credits (or equivalent): Yes ☐ No ☐ If yes, please indicate the number of credits: …. Give a grade: Yes ☐ No ☐ If yes, please indicate if this will be based on: Traineeship certificate ☐ Final report ☐ Interview ☐ Record the traineeship in the trainee's Transcript of Records: Yes ☐ No ☐ Record the traineeship in the trainee's Diploma Supplement (or equivalent). Record the traineeship in the trainee's Europass Mobility Document: Yes ☐ No ☐ The traineeship is carried out by a recent graduate and, upon satisfactory completion of the traineeship, the institution undertakes to: Award ECTS credits (or equivalent): Yes ☐ No ☐ If yes, please indicate the number of credits: …. Record the traineeship in the trainee's Europass Mobility Document (highly recommended): Yes ☐ No ☐ Accident insurance for the trainee The Sending Institution will provide an accident insurance to the trainee (if not provided by the Receiving Organisation/Enterprise): Yes ☐ No ☒ The accident insurance covers: - accidents during travels made for work purposes: Yes ☐ No ☒ - accidents on the way to work and back from work: Yes ☐ No ☒

  • General Operation Seller shall comply with all applicable requirements of Law, the CAISO, NERC and WECC relating to the Project (including those related to construction, ownership and/or operation of the Project).

  • Monitoring and Inspection The Interconnected Transmission Owner may monitor construction and installation of Interconnection Facilities that the Interconnection Customer is constructing. Upon reasonable notice, authorized personnel of the Interconnected Transmission Owner may inspect any or all of such Interconnection Facilities to assess their conformity with Applicable Standards.

  • Monitoring Compliance Upon the request of the Lender, but without incurring any liability beyond the Guaranteed Obligations, from time to time, Guarantor shall promptly provide to the Lender such documents, certificates and other information as may be deemed reasonably necessary to enable the Lender to perform its functions under the Servicing Agreement as the same relates to the Guarantor.

  • GENERAL OPERATIONAL REQUIREMENTS 12.1 Interference or damage to Distributor's Equipment by Customers: The Trader must, subject to clause 29.1, include in each of its Customer Agreements a requirement that, during the term of the Customer Agreement and until the end of the period ending on the earlier of 6 months after the termination of the Customer Agreement or the date on which a new Customer Agreement is entered into in respect of the relevant ICP, the Customer must not interfere with or damage, and must ensure that its agents and invitees do not interfere with or damage, the Distributor's Equipment without the prior written consent of the Distributor (except to the extent that emergency action has to be taken to protect the health or safety of persons or to prevent damage to property).

  • Scheduling of Overtime In any case where no employee is available to work a shift or the extension of a shift at straight time, and the Employer thereupon determines that it is necessary to assign the work on an overtime basis, the following provisions will govern the assignment of the overtime.

Time is Money Join Law Insider Premium to draft better contracts faster.