Felling, Bucking, Brushing and Limbing Plans Sample Clauses

Felling, Bucking, Brushing and Limbing Plans. ‌ Apply the following planning logic (OHLEC) to all phases of saw operations: Objective‌ Regardless of task, develop a plan to determine where you want the cut piece to end up. • If felling, plan the most desirable placement or lay for the tree • If bucking, plan where you want the bucked log or round to go • If limbing, determine sequence and direction for large branches when cut • If brushing, particularly in thick brush, plan how you will remove the brush when it is cut 8 (29 CFR 1910.266(d)(5)) Hazards/obstacles‌ Develop a plan to identify the hazards/obstacles: • That are overhead (fire, rotten top, widow makers and loose bark) • That are in the piece of wood being cut (fire, rot and hinge wood integrity, hollow, bar/saw length compared to diameter, bees or poison plants) • Springpoles • Buildings, equipment or other trees you don’t want damaged • That are associated with people and cutting area control Leans/binds‌ Since lay, cut piece placement, sequence or removal was determined in O develop a plan to: • Determine lean of a standing tree and calculate, in feet, the amount of head/back lean and side lean • Determine binds in log to be bucked, springpoles, limbs or brush to be removed Escape routes‌ Since leans and binds were determined in the previous step develop a plan to: • Determine the ‘good’ and ‘bad’ side of the tree, log, springpole, limb or brush • Determine and clear an escape route (or 2 routes if necessary for crosscut saw/axe work or situations that require two routes) Cut Plan‌ Develop a cut plan to determine which technique will be used to remove wood fiber to achieve the desired result including: • Face notch construction type (conventional, Humboldt or open face) • Hinge position, length of hinge, depth of hinge and amount of xxxxx shot needed • Back cut type (straight in from the back or chase, boring back cut and out the back, boring back cut with release or holding wood or strap) • Wedge placement including number of wedges and axe placement • Xxxxxx communication to crew members, swamper or crosscut xxxxxx partner
AutoNDA by SimpleDocs

Related to Felling, Bucking, Brushing and Limbing Plans

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • Switching and Tagging Rules Each Party shall provide the other Parties a copy of its switching and tagging rules that are applicable to the other Parties’ activities. Such switching and tagging rules shall be developed on a non-discriminatory basis. The Parties shall comply with applicable switching and tagging rules, as amended from time to time, in obtaining clearances for work or for switching operations on equipment.

  • Skidding and Yarding Methods of skid- ding or yarding specified for particular areas, if any, are indicated on Sale Area Map. Outside Clearcutting Units and construction clearings, insofar as ground conditions permit, products shall not be skidded against reserve trees or groups of reproduction and tractors shall be equipped with a winch to facilitate skidding. B6.421 Rigging. Insofar as practicable, needed rigging shall be slung on stumps or trees desig- nated for cutting.

  • Felling and Bucking Felling shall be done to minimize breakage of Included Timber and dam- age to residual timber. Unless agreed otherwise, felling shall be done by saws or shears. Bucking shall be done to permit removal of all minimum pieces set forth in A2. Purchaser may buck out cull material when necessary to produce pieces meeting Utilization Standards. Such bucked out material shall contain a minimum amount of sound wood, not in excess of the net scale in percentage of gross scale, or based on the merchantability factor, whichever is stated in A2. If necessary to assess extent of defect, Purchaser shall make sample saw cuts or wedges. B6.411 Felling in Clearings. Insofar as ground conditions, tree lean, and shape of clearings per- mit, trees shall be felled so that their tops do not extend outside Clearcutting Units, construction clearings, and ar- eas of regeneration cutting. B6.000 Xxxxx Xxxxxxx. Stumps shall not exceed, on the side adjacent to the highest ground, the maximum heights set forth in A6, except that occasional stumps of greater heights are acceptable when Purchaser determines that they are necessary for safe and efficient conduct of logging. Unless otherwise agreed, Purchaser shall re-cut high stumps so they will not exceed heights specified in A6 and shall dispose of severed portions in the same manner as other logging debris. The xxxxx heights shown in A6 were selected with the objective of maximum reasonable utilization of the timber, unless Sale Area Map shows special areas where xxxxx heights are lower for aesthetic, land treatment, or silvicultural rea- sons.

  • OVATIONS FOOD SERVICES, L.P. dba SPECTRA All food and beverage service must be discussed with and approved by Spectra, the OCFEC Master Concessionaire. FORM F-31 AGREEMENT NO. R-026-18 DATE May 16, 2018 REVIEWED APPROVED RENTAL AGREEMENT FAIRTIME INTERIM XX THIS AGREEMENT by and between the 32nd District Agricultural Association dba OC Fair & Event Center, hereinafter called the Association, and B & L Productions, Inc. hereinafter, called the Rentor

  • Required Coverages For Generation Resources Of 20 Megawatts Or Less Each Constructing Entity shall maintain the types of insurance as described in section 11.1 paragraphs (a) through (e) above in an amount sufficient to insure against all reasonably foreseeable direct liabilities given the size and nature of the generating equipment being interconnected, the interconnection itself, and the characteristics of the system to which the interconnection is made. Additional insurance may be required by the Interconnection Customer, as a function of owning and operating a Generating Facility. All insurance shall be procured from insurance companies rated “A-,” VII or better by AM Best and authorized to do business in a state or states in which the Interconnection Facilities are located. Failure to maintain required insurance shall be a Breach of the Interconnection Construction Service Agreement.

  • Cutting and Patching The Contractor shall be responsible for cutting, fitting or patching required to complete the Work or to make its parts fit together properly.

  • Alignment with Modernization Foundational Programs and Foundational Capabilities The activities and services that the LPHA has agreed to deliver under this Program Element align with Foundational Programs and Foundational Capabilities and the public health accountability metrics (if applicable), as follows (see Oregon’s Public Health Modernization Manual, (xxxx://xxx.xxxxxx.xxx/oha/PH/ABOUT/TASKFORCE/Documents/public_health_modernization_man ual.pdf):

  • Provisioning of Line Sharing and Splitter Space 3.2.1 BellSouth will provide ONS with access to the High Frequency Spectrum as follows:

  • Green Economy/Carbon Footprint a) The Supplier/Service Provider has in its bid provided Transnet with an understanding of the Supplier’s/Service Provider’s position with regard to issues such as waste disposal, recycling and energy conservation.

Time is Money Join Law Insider Premium to draft better contracts faster.