AIR MOTOR Sample Clauses

AIR MOTOR. The term "Air Motor" shall mean all of Seller's drawings, blueprints, sketches, diagrams, specifications, bills of material, manufacturing cost records, cost estimates, engineering records, engineering notes and notebooks, service manuals, service instructions, manufacturing instructions, assembly instructions, testing instructions, operating instructions, parts lists, know-how data, technology, methodology, prototypes, programs, models, tools, pattern, and other physical and written descriptions and embodiments, including parts, subsystems and subassemblies related to a single piston one cylinder motor complete with all associated fittings together with a four cylinder 902 Kubota air converted motor and all associated fittings and compressor and a prototype machine for the production of an Air Motor, which Seller has manufactured and tested which are possessed by Seller as of the date hereof, together with any future improvements thereto or betterments thereof whether made by Seller or Buyer.
AutoNDA by SimpleDocs

Related to AIR MOTOR

  • Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.

  • Ambulance Services Ground Ambulance This plan covers local professional or municipal ground ambulance services when it is medically necessary to use these services, rather than any other form of transportation as required under R.I. General Law § 27-20-55. Examples include but are not limited to the following: • from a hospital to a home, a skilled nursing facility, or a rehabilitation facility after being discharged as an inpatient; • to the closest available hospital emergency room in an emergency situation; or • from a physician’s office to an emergency room. Our allowance for ground ambulance includes the services rendered by an emergency medical technician or paramedic, as well as any drugs, supplies and cardiac monitoring provided. Air and Water Ambulance This plan covers air and water ambulance services when: • the time needed to move a patient by land, or the instability of transportation by land, may threaten a patient’s condition or survival; or • if the proper equipment needed to treat the patient is not available from a ground ambulance. The patient must be transported to the nearest facility where the required services can be performed and the type of physician needed to treat the patient’s condition is available. Our allowance for the air or water ambulance includes the services rendered by an emergency medical technician or paramedic, as well as any drugs, supplies and cardiac monitoring provided.

  • Logistics The Licensee shall be responsible for:

  • NFFE An “NFFE” means any Non-U.S. Entity that is not an FFI as defined in relevant U.S. Treasury Regulations, and also includes any Non- U.S. Entity that is resident in [FATCA Partner] or other Partner Jurisdiction and that is not a Financial Institution.

  • PORTFOLIO HOLDINGS The Adviser will not disclose, in any manner whatsoever, any list of securities held by the Portfolio, except in accordance with the Portfolio’s portfolio holdings disclosure policy.

  • Ambulance Escort Where a nurse is assigned to provide patient care for a patient in transit, the following provisions shall apply:

  • Originating Goods Except as otherwise provided in this Chapter, each Party shall provide that a good is originating if it is:

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Ambulance The deductible and coinsurance for services not subject to copays applies.

  • OASIS The ISO shall maintain the OASIS for the New York Control Area.

Time is Money Join Law Insider Premium to draft better contracts faster.