Examples of Covered Flare in a sentence
The Defendants must comply with all applicable Subparts of 40 C.F.R. Parts 60, 61, or 63 that state how a particular Covered Flare must be monitored.
In no event shall Instrument Downtime exceed 5% of the time in a Calendar Quarter that the Covered Flare affected by the Instrument Downtime is In Operation.
The Defendants must monitor and calculate NHVvg at each Covered Flare in accordance with Appendix 1.2, except as provided below for the Finishing Flare at the Baton Rouge Plastics Plant.
The Defendants must operate each Covered Flare with a pilot flame present at all times.
For each Covered Flare, the Defendants must install, operate, calibrate, and maintain a monitoring system capable of continuously measuring, calculating, and recording the volumetric flow rate of Vent Gas in the header or headers feeding that Covered Flare.
For any planned or unplanned outage of a Covered Flare that the Defendants know or reasonably anticipate will result in 504 hours or less of downtime on a 1,095-Day rolling sum period, rolled daily, the Defendants must make good faith efforts to ensure that the Portable Flare that replaces the Covered Flare complies with all of the requirements of this Consent Decree that are applicable to the Covered Flare that the Portable Flare replaces.
Except as provided in Paragraph46 (Portable Flares), by no later than the date that any Newly Installed Covered Flare or Portable Flare is In Operation and Capable of Receiving Waste, Supplemental, and/or Sweep Gas at a Covered Facility, the Defendants must complete installation and commence operation of the instrumentation, controls, and monitoring systems set forth in Paragraphs 20–23.
At its option, in order to continuously measure and calculate flow, in scfm and pounds per hour, of all Pilot Gas to a Covered Flare, the Defendants may elect to either: a) install (if not already installed) an instrument or b) use a restriction orifice and pressure measurements.
To demonstrate continuous compliance with the 98% Combustion Efficiency, the Defendants must operate each Covered Flare in compliance with the applicable requirements in Paragraph 43.
By no later than the Effective Date, the Defendants must operate each Covered Flare with a minimum of a 98% Combustion Efficiency at all times when Waste Gas is vented to it.