Test protocols and reports Sample Clauses

Test protocols and reports. Provide the detailed test protocol to the Employer and the Employer’s representative, at least two (2) weeks before the commencement of any tests during commissioning. The Employer, Employer’s representative and the Contractor shall agree on test protocol before the commencement of any tests. The Test protocol shall include but not limited to: o Definition of each test type and test methods; o List of equipment to be used along with their specification and relevant certificates; o Duration of each test; o Test evaluation method and Acceptance/Rejection criteria.  Provide the report to the Employer and the Employer’s representative upon the successful completion of the tests during commissioning and issue of the Certificate of Practical Completion. The report shall include following but not limited to: o Overview of the Plant. o General Information:  Company profiles. o Acceptance protocols:  SANS 10142 certificates;  Earth resistivity test result;  MV test certificate. o Solar module:  Data sheet;  Certificates;  Manual;  Mounting approval;  Flash list. o Inverter:  Data sheet;  Certificates;  Serial numbers;  String measurements;  Manual;  Service manual. o LV-reticulation:  Communication board;  Field DB;  Main LV board. o Transformer and switchgear;  Data sheets;  Certificates;  Test reports;  Foundation layouts. o Cables and connectors:  List of installed cables;  DC cable data sheets and certificates;  AC cable data sheets and certificates;  MV cable data sheets and certificates;  Speed/data wire cable data sheets and certificates;  Fibre optic able data sheets and certificates;  MC4 connector data sheets and certificates;  Cable lugs data sheets and certificates. o Substructure:  Data sheets;  Certificates;  Detailed drawings;  Test loading report. o Monitoring:  Data sheets  Certificates;  Wiring plan;  Cluster controller manual;  Irradiation sensor;  Ambient temperature sensor;  Module temperature sensor;  IP addresses;  GSM router;  Display screen. o Plans and drawings:  11 kV schematic;  Trenches;  String overview;  Earthing layout;  DC circuit diagram;  Camera layout;  Lightning protection layout. o Surge protection:  Lightning protection layout;  Inverter data sheets and certificates.
AutoNDA by SimpleDocs

Related to Test protocols and reports

  • Filings and Reports (a) Each year during the term of the Fee Agreement, the Company and any Sponsor Affiliates shall deliver to the County, the County Auditor, the County Assessor and the County Treasurer a copy of their most recent annual filings with the Department with respect to the Project, not later than thirty (30) days following delivery thereof to the Department.

  • Data and Reports The School is consistent in providing information, data, documentation, evindence and reports requested by the Commission pursuant to HRS §302D-17. x Review of submissions.

  • Diverse Spend Reporting If the total value of the Contract may exceed $500,000, including all extension options, Contractor must track and report, on a quarterly basis, the amount paid to diverse businesses both: 1) directly to subcontractors performing under the Contract, and 2) indirectly to diverse businesses that provide supplies/services to your company (in proportion to the revenue from this Contract compared to Contractor’s overall revenue). When this applies, Contractor will register in a free portal to help report the Tier 2 diverse spend, and the requirement continues as long as the Contract is in effect.

  • PERFORMANCE MONITORING AND REPORTING Performance indicators

  • Monitoring and Reporting 3.1 The Contractor shall provide workforce monitoring data as detailed in paragraph 3.2 of this Schedule 8. A template for data collected in paragraphs 3.2, 3.3 and 3.4 will be provided by the Authority. Completed templates for the Contractor and each Sub-contractor will be submitted by the Contractor with the Diversity and Equality Delivery Plan within six (6) Months of the Commencement Date and annually thereafter. Contractors are required to provide workforce monitoring data for the workforce involved in delivery of the Contract. Data relating to the wider Contractor workforce and wider Sub-contractors workforce would however be well received by the Authority. Contractors and any Sub-contractors are required to submit percentage figures only in response to paragraphs 3.2(a), 3.2(b) and 3.2(c).

  • Funding, Services and Reporting The HSP represents warrants and covenants that

  • Safeguards Monitoring and Reporting 8. The Borrower shall do the following or cause the Project Executing Agency to do the following:

  • Studies and Reports All copies in the Seller’s possession of studies and/or reports which have previously been performed in connection with or for the Property, including without limitation, environmental reports, soils studies, seismic studies, physical inspection reports, site plans and surveys, and identification of such studies of which the Seller is aware but that are not in their possession;

  • Implementation of and Reporting on the Project A. The Grantee shall implement and complete the Project in accordance with Exhibit A and with the plans and specifications contained in its Grant Application, which is on file with the State and is incorporated by reference. Modification of the Project shall require prior written approval of the State.

  • Records and Reporting 7.01. The Implementing Entity shall provide to the Board, through the Secretariat, the following reports and financial statements:

Time is Money Join Law Insider Premium to draft better contracts faster.