Stockpile Location. Welchers Pit 1 ¼ Inch Minus 500 Welchers Pit 6-67 ROCK STOCKPILE SPECIFICATIONS Rock stockpiles listed in Clause 6-65 ROCK STOCKPILE LOCATION must meet the following specifications: Before placing aggregates upon the stockpile site, the site must be cleared of vegetation, trees, stumps, brush, rocks, or other debris and the ground leveled to a smooth, firm, uniform surface. When completed, the stockpile must be neat and regular in shape. The stockpile height is limited to a maximum of 24 feet. Stockpiles in excess of 200 cubic yards must be built up in layers of not more than 4 feet deep. Stockpile layers must be constructed by trucks, clamshells, or other methods approved in writing by the Contract Administrator. Each layer must be completed over the entire area of the pile before depositing aggregates in the next layer. The aggregates may not be dumped so that they run down and over the lower layers in the stockpile. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates.
Appears in 3 contracts
Samples: www.dnr.wa.gov, www.dnr.wa.gov, www.dnr.wa.gov
Stockpile Location. Welchers Pit Harmony Quarry 1 ¼ Inch ½” Minus 500 Welchers Pit Crushed 1500 Harmony Quarry 6-67 ROCK STOCKPILE SPECIFICATIONS Rock stockpiles listed in Clause 6-65 6−65 ROCK STOCKPILE LOCATION must meet the following specifications: Before placing aggregates upon the stockpile site, the site must be cleared of vegetation, trees, stumps, brush, rocks, or other debris and the ground leveled to a smooth, firm, uniform surface. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates. When completed, the stockpile must be neat and regular in shape. The stockpile height is limited to a maximum of 24 20 feet. Stockpiles in excess of 200 cubic yards must be built up in layers of not more than 4 5 feet deep. Stockpile layers must be constructed by trucks, clamshells, or other methods approved in writing by the Contract Administrator. Each layer must be completed over the entire area of the pile before depositing aggregates in the next layer. The aggregates may not be dumped so that they run down and over the lower layers in the stockpile. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates.
Appears in 1 contract
Samples: All State Unless Otherwise Noted
Stockpile Location. Welchers Pit 1 ¼ Inch ROLLIN ROCK PIT 3-Inch-Minus 500 Welchers Pit ROLL PIT 6-67 ROCK STOCKPILE SPECIFICATIONS Rock stockpiles listed in Clause 6-65 ROCK STOCKPILE LOCATION must meet the following specifications: Before placing aggregates upon the stockpile site, the site must be cleared of vegetation, trees, stumps, brush, rocks, or other debris and the ground leveled to a smooth, firm, uniform surface. When completed, the stockpile must be neat and regular in shape. The stockpile height is limited to a maximum of 24 feet. Stockpiles in excess of 200 500 cubic yards must be built up in layers of not more than 4 feet deep. Stockpile layers must be constructed by trucks, clamshells, or other methods approved in writing by the Contract Administrator. Each layer must be completed over the entire area of the pile before depositing aggregates in the next layer. The aggregates may not be dumped so that they run down and over the lower layers in the stockpile. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates.. SUBSECTION ROCK APPLICATION
Appears in 1 contract
Samples: www.dnr.wa.gov
Stockpile Location. Welchers Pit 1 ¼ Inch Minus 500 Welchers Pit Washtub Quarry 4” Jaw Run 1000 Washtub Quarry 6-67 ROCK STOCKPILE SPECIFICATIONS Rock stockpiles listed in Clause 6-65 ROCK STOCKPILE LOCATION must meet the following specifications: DRAFT Before placing aggregates upon the stockpile site, the site must be cleared of vegetation, trees, stumps, brush, rocks, or other debris and the ground leveled to a smooth, firm, uniform surface. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates. When completed, the stockpile must be neat and regular in shape. The stockpile height is limited to a maximum of 24 20 feet, unless otherwise approved by the Contract Administrator. Stockpiles in excess of 200 cubic yards must be built up in layers of not more than 4 5 feet deep. Stockpile layers must be constructed by trucks, clamshells, or other methods approved in writing by the Contract Administrator. Each layer must be completed over the entire area of the pile before depositing aggregates in the next layer. The aggregates may not be dumped so that they run down and over the lower layers in the stockpile. Stockpiles of different types or sizes of aggregate must be spaced far enough apart, or separated by suitable walls or partitions, to prevent the mixing of the aggregates.
Appears in 1 contract