Quality Improvement VRC shall develop programs designed to improve the quality of care provided by the Radiologists and encourage identification and adoption of best demonstrated processes. Practice and VRC acknowledge that, in connection with such quality improvement activities, it may be necessary to provide VRC with Protected Health Information and Practice and VRC agree to treat such information in accordance with Article 9;
Quality Control A. Controlled Affiliate agrees to use the Licensed Marks and Name only in connection with the licensed services and further agrees to be bound by the conditions regarding quality control shown in attached Exhibit A as they may be amended by BCBSA from time-to-time.
Quality Assurance The parties endorse the underlying principles of the Company’s Quality Management System, which seeks to ensure that its services are provided in a manner which best conforms to the requirements of the contract with its customer. This requires the Company to establish and maintain, implement, train and continuously improve its procedures and processes, and the employees to follow the procedures, document their compliance and participate in the improvement process. In particular, this will require employees to regularly and reliably fill out documentation and checklists to signify that work has been carried out in accordance with the customer’s specific requirements. Where necessary, training will be provided in these activities.
Quality Assurance/Quality Control Contractor shall establish and maintain a quality assurance/quality control program which shall include procedures for continuous control of all construction and comprehensive inspection and testing of all items of Work, including any Work performed by Subcontractors, so as to ensure complete conformance to the Contract with respect to materials, workmanship, construction, finish, functional performance, and identification. The program established by Contractor shall comply with any quality assurance/quality control requirements incorporated in the Contract.
Quality Monitoring 4.2.1. To prepare a Quality Assurance (QA) Plan
Quality Requirements Performance Indicator Heading Indicator (specific) Threshold Method of Measurement Frequency of monitoring Consequence of Breach QUALITY Patient Safety - Incidents I1 Number of incidents Adverse incidents include the following: clinical or non clinical adverse events that have potential to cause avoidable harm to a patient, including medical errors or adverse events related to medical devices or other equipment. Clinical or non- clinical accidents, accidental injuries to staff and members of the public, verbal, physical or psychological abuse or harassment, unusual or dangerous occurrences, damage to trust property, plant or equipment, fire or flood, security, theft or loss, near misses are identified as any event where under different circumstances significant injury or loss may have occurred Number of recorded incidents in the contract month Monthly Remedial Action Plan brought to Performance Meeting following breach; action under Module C Clause 32 if needed I2 Number of Sis Definition of SUI according to trust policy and national guidance Number of Serious Untoward Incidents reported in contract month Monthly Remedial Action Plan brought to Performance Meeting following breach; action under Module C Clause 32 if needed S1 Percentage of eligible staff received child safeguarding training at level 2 (as identified in LSCB training strategy) 95% Number received training/ Number of identified staff requiring training Monthly S2 Percentage of eligible staff received adult safeguarding awareness training at level 2 ( as identified in K&M Safeguarding Vulnerable Adults training strategy) 95% Number of staff trained/ Number of identified staff requiring training Monthly
Quality Management Grantee will:
Quality All products will be new and unused. All products provided by the Contractor must meet all federal, state, and local standards for quality and safety requirements. Products not meeting the requirements of this section will be deemed unacceptable and returned to the Contractor for credit at no charge to the State.
Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.
Manufacturers Promptly after obtaining actual knowledge thereof, notice of any Manufacturer Event of Default or termination or replacement of a Manufacturer Program;