Quality Assurance and Testing Sample Clauses

The Quality Assurance and Testing clause establishes the standards and procedures for verifying that goods or services meet specified requirements before acceptance. It typically outlines the methods, timing, and responsibilities for conducting inspections, tests, or reviews, and may require the supplier to remedy any deficiencies identified during this process. This clause ensures that deliverables conform to agreed-upon quality benchmarks, thereby reducing the risk of defects and disputes over performance.
Quality Assurance and Testing. During software development, IT Consultant shall include a phase for quality assurance and testing of all Software. Quality assurance and testing must follow documented industry standard methodology, protocol and best practices and be previously approved by an appropriate District Director of Administrative/Academic Systems. Quality assurance and testing documentation should include the following: i. Quality assurance and testing overview. ii. Module and functionality testing. iii. Modifications based upon quality control and quality assurance testing results. The IT Consultant, District IT and designated District and college end users will conduct quality assurance testing.
Quality Assurance and Testing a) The supply will be accepted only after quality assurance tests are carried out by the Quality Assurance Wing of BSNL as per prescribed schedule and material passing the test successfully and after authenticated gate pass issued by concerned Authorities. b) The QA units of BSNL while clearing the equipment/ stores will strictly adhere to the package discipline as described in Purchase Order. Supplies made in full, as per Purchase Order, of all the packages during delivery period only will be deemed to have been supplied within the scheduled delivery period.
Quality Assurance and Testing. During-the delivery of the project, RightNow will provide quality assurance to Customer on the configuration of RightNow during the implementation. The QA process will ensure the RightNow configuration conforms to RightNow best practices guidance and meets the business requirements agreed to within the scope of services. Customer will be responsible for acceptance testing against its business requirements. This includes test planning and management, test case development, and execution of acceptance tests at the individual test case level. RightNow services will be limited to assisting the Customer with test case execution, investigating the root cause of failed test cases and assisting with resolution (if applicable.) It is assumed that the implementation will be rolled out in two phases with each phase involving a QA and testing cycle. RightNow Professional Services hours will be split between the two rollout phases. Quality Assurance and Testing 40 hours
Quality Assurance and Testing. Supplier shall apply quality control and quality assurance procedures and in-plant quality control checks for the AQP Products in accordance with industry best practices, and prior to shipment, Supplier will, at its sole cost, perform a full panel of testing on all AQP Products to the extent deemed necessary by TCAM or as otherwise required to confirm compliance with the GALT Standards.
Quality Assurance and Testing. Seller will continue to perform quality assurance and testing with respect to the Buyer’s toner business, as historically performed for the Toner Business, including, without limitation, inventory inspection, testing and reporting.
Quality Assurance and Testing. The Supplier will provide the full contact details of its Quality Manager, or member of staff responsible for quality approval and processes no later than two weeks after the signing of the contract. A quality plan will be generated by the Supplier and this documentation will be made available to the Customer. The Plan should be based around the ‘Bill of Materials’ for the complete deliverable which shows the detail concerning the inspection and testing criteria of each individual part. The plan must also indicate details concerning the documented processes and quality control records that will be used and made available to the Customer. The Supplier will grant access to its work premises for the Customer to undertake periodic quality control inspections as required. These events will generally be associated with the completion of elements of the order where milestone payments are due and during testing and certification of product. The Supplier shall notify the Customer of such events providing a minimum of 14 calendar days’ notice.
Quality Assurance and Testing. Design/Builder shall establish and implement a written quality assurance and testing program that is appropriate for the Project. Owner shall have the right to review such program and receive copies of any test reports, if requested. Owner shall have the right, at Owner's expense, to perform any additional testing or inspection that it deems necessary. If such additional testing reveals the presence of substandard, defective or non-conforming Work, Design/Builder shall pay the cost of such testing.

Related to Quality Assurance and Testing

  • Quality Assurance The parties endorse the underlying principles of the Company’s Quality Management System, which seeks to ensure that its services are provided in a manner which best conforms to the requirements of the contract with its customer. This requires the Company to establish and maintain, implement, train and continuously improve its procedures and processes, and the employees to follow the procedures, document their compliance and participate in the improvement process. In particular, this will require employees to regularly and reliably fill out documentation and checklists to signify that work has been carried out in accordance with the customer’s specific requirements. Where necessary, training will be provided in these activities.

  • Quality Assurance Requirements There are no special Quality Assurance requirements under this Agreement.

  • Quality Assurance Program An employee shall be entitled to leave of absence without loss of earnings from her or his regularly scheduled working hours for the purpose of writing examinations required by the College of Nurses of Ontario arising out of the Quality Assurance Program.

  • Quality Assurance/Quality Control Contractor shall establish and maintain a quality assurance/quality control program which shall include procedures for continuous control of all construction and comprehensive inspection and testing of all items of Work, including any Work performed by Subcontractors, so as to ensure complete conformance to the Contract with respect to materials, workmanship, construction, finish, functional performance, and identification. The program established by Contractor shall comply with any quality assurance/quality control requirements incorporated in the Contract.

  • COUNTY’S QUALITY ASSURANCE PLAN The County or its agent will evaluate the Contractor’s performance under this Contract on not less than an annual basis. Such evaluation will include assessing the Contractor’s compliance with all Contract terms and conditions and performance standards. Contractor deficiencies which the County determines are severe or continuing and that may place performance of the Contract in jeopardy if not corrected will be reported to the Board of Supervisors. The report will include improvement/corrective action measures taken by the County and the Contractor. If improvement does not occur consistent with the corrective action measures, the County may terminate this Contract or impose other penalties as specified in this Contract.