– Inclusion of Watershed Connections Sample Clauses

– Inclusion of Watershed Connections. Because of the relatively flat topography of the region, several hydraulic connections between the Xxxx and Xxxxxxx Bay watershed and adjacent watersheds exist during major flood events. This Task includes developing strategies and model adjustments to consider these hydraulic connections. Any field surveying needed to complete this task will be certified and provided by the COUNTY. A brief summary of the number of connections and approach to address each are provided below: • Myakka River – Up to 15 connections between the Xxxx and Xxxxxxx Bay watershed and the Myakka River watershed will be considered from Center Road to State Road 72. Connections between adjacent subbasins will be addressed by inclusion of up to 3 adjacent subbasins in the Myakka River watershed into the Xxxx and Xxxxxxx Bay watershed model. In addition, to address known overflows and diversions from the Myakka River itself, hydrographs will be developed at up to 15 Myakka River nodes and used with available stage/discharge information from the 1978 USGS report to develop time-stage rating curves at each node along the Myakka River between I-75/Xxxxxxxxx canal and the Pinelands Reserve. Deliverables: • Digital ICPR input file for the updated Xxxx and Xxxxxxx Bay watershed model • Digital ICPR output files for the 2-year, 5-year, 10-year, 25-year and 100-year design storm simulations • Digital GIS map of 100-year floodplain file for the Xxxx and Xxxxxxx Bay watershed update • Brief report, consistent with the Cow Pen Slough/Shakett Creek Basin Master Plan Update, as applicable, in hard (3 copies) and digital format summarizing the modeling approach and results.
AutoNDA by SimpleDocs

Related to – Inclusion of Watershed Connections

  • Foreign-Owned Companies in Connection with Critical Infrastructure If Texas Government Code, Section 2274.0102(a)(1) (relating to prohibition on contracts with certain foreign-owned companies in connection with critical infrastructure) is applicable to this Contract, pursuant to Government Code Section 2274.0102, Contractor certifies that neither it nor its parent company, nor any affiliate of Contractor or its parent company, is: (1) majority owned or controlled by citizens or governmental entities of China, Iran, North Korea, Russia, or any other country designated by the Governor under Government Code Section 2274.0103, or (2) headquartered in any of those countries.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Internet Connection In order to ensure the proper functioning of the Production Monitor and the Consumption Monitor, if possible, you must provide the Solar System with continuous access to a functioning broadband internet connection with one (1) wired Ethernet port and standard electrical outlet, at your cost. If you are unable to provide the Solar System with an internet connection in accordance with the foregoing sentence, the Home must be located in an area with cellular service that is acceptable to us in our discretion.

  • Exception Where Databases Contain Sufficient Information A Reporting Financial Institution is not required to perform the paper record search described in subparagraph D.2. of this section if the Reporting Financial Institution’s electronically searchable information includes the following:

  • Electrical connections Equipment requiring electrical connections for operation shall either be hard wired to the Authorized User's provided connections or the Contractor shall be responsible for a male electrical union. All connections shall be made by the Contractor and accomplished in accordance with National Electrical Code requirements. Electrically operated equipment shall be available in the following volts and phases: 208 volt 1 or 3 phase, 60 HZ 220 volt 1 or 3 phase, 60 HZ 440 volt 1 or 3 phase, 60 HZ

  • Information regarding Interconnection Facilities 4.2.1 The SPD shall be required to obtain all information from the STU/CTU/concerned authority with regard to the Interconnection Facilities as is reasonably necessary to enable it to design, install and operate all interconnection plant and apparatus on the SPD’s side of the Delivery Point to enable delivery of electricity at the Delivery Point. The transmission of power up to the point of interconnection where the metering is done for energy accounting shall be the responsibility of the SPD at his own cost.

  • Trunk Group Connections and Ordering 5.2.1 For both One-Way and Two-Way Interconnection Trunks, if Onvoy wishes to use a technically feasible interface other than a DS1 or a DS3 facility at the POI, the Parties shall negotiate reasonable terms and conditions (including, without limitation, rates and implementation timeframes) for such arrangement; and, if the Parties cannot agree to such terms and conditions (including, without limitation, rates and implementation timeframes), either Party may utilize the Agreement’s dispute resolution procedures.

  • Accessibility of Web-Based Information and Applications For State Agency Authorized User Acquisitions: Any web-based information and applications development, or programming delivered pursuant to the contract or procurement, will comply with New York State Enterprise IT Policy NYS-P08-005, Accessibility of Web-Based Information and Applications as follows: Any web-based information and applications development, or programming delivered pursuant to the contract or procurement, will comply with New York State Enterprise IT Policy NYS-P08- 005, Accessibility of Web-Based Information and Applications as such policy may be amended, modified or superseded, which requires that state agency web-based information and applications are accessible to persons with disabilities. Web-based information and applications must conform to New York State Enterprise IT Policy NYS-P08-005 as determined by quality assurance testing. Such quality assurance testing will be conducted by the State Agency Authorized User and the results of such testing must be satisfactory to the Authorized User before web-based information and applications will be considered a qualified deliverable under the contract or procurement.

  • Procedures for Providing NP Through Full NXX Code Migration Where a Party has activated an entire NXX for a single Customer, or activated at least eighty percent (80%) of an NXX for a single Customer, with the remaining numbers in that NXX either reserved for future use by that Customer or otherwise unused, if such Customer chooses to receive Telephone Exchange Service from the other Party, the first Party shall cooperate with the second Party to have the entire NXX reassigned in the LERG (and associated industry databases, routing tables, etc.) to an End Office operated by the second Party. Such transfer will be accomplished with appropriate coordination between the Parties and subject to appropriate industry lead times for movements of NXXs from one switch to another. Neither Party shall charge the other in connection with this coordinated transfer.

  • Road Surfaces (1) Grade, shape, crown, and/or outslope surface and shoulders.

Time is Money Join Law Insider Premium to draft better contracts faster.