Gear Speed Reducers Sample Clauses

Gear Speed Reducers. Speed reducers will be parallel shaft designed specifically for the service. Spiral bevel or spiral bevel/helical gears will be designed in accordance with AGMA standards for gear wear, gear strength, shaft bending stress, torsional stress, and bearing performance. All gears will have a minimum service factor of 2.0 based on design fan horsepower, and be suitable for forward operation. The oil fill lines (will be metal or armor covered) will be accessible and provided with an oil level sight glass to facilitate routine inspection and maintenance. The gear case will be dowelled in position after final alignment of the equipment.
AutoNDA by SimpleDocs

Related to Gear Speed Reducers

  • Dollar Limits Per Service Agreement Cost to diagnose, repair and/or replace - Geothermal and water source systems $1,500 Water cooled air conditioners, high velocity and hydronic systems $1,500 Concrete encased or concealed ductwork $500 Refrigerant lines $500 Appliances l Standard/Seller Coverage S Supreme Coverage l S Appliance color matchSM l S Built-in microwave l S Dishwasher l S Garbage disposal l S Range, oven, cooktop and vent hood l S Refrigerator - INCLUDING ICE MAKER! S Washer and dryer S Range, oven, cooktop, hood: handles, hinges, clocks, rotisseries, racks, knobs and dials, interior lining, glass/ceramic cooktops, self cleaning mechanisms and latch assemblies S Kitchen Refrigerator: handles, hinges, ice crusher, beverage dispenser and respective equipment S Built-in microwave: handles, hinges, interior lining, clocks and shelves, turntable platforms and rollers S Dishwasher: handles, hinges, racks, baskets, rollers, tub and interior lining, springs, latch assemblies and soap dispensers S Permits up to $250 per Service Agreement S Modifications up to $250 per Service Agreement S Haul away/disposal fees S Items under manufacturer’s warranty Excluded Items: ✖ Appliances not located in the primary kitchen (except washer and dryer) and duplicate appliances, unless additional refrigerator option(s) are purchased. ✖ Meat probe assemblies, door glass, sensi-heat burners will only be replaced with standard burners for range, oven, cooktop. ✖ Multimedia center including technology convenience items like LCD screens, Wi-Fi and cameras. ✖ Racks, hinges, shelves, interior thermal shells, food spoilage and freezers which are not an integral part of the kitchen refrigerator. ✖ Door glass, portable or counter top units, trim kits, meat probe assemblies, rotisseries for built-in microwave. ✖ Damage to clothing, plastic mini-tub, soap dispensers, filter screens, knobs, dials, hinges and lint screen for washer or dryer. ✖ Gas supply line to stove.

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

  • EPP service availability Refers to the ability of the TLD EPP servers as a group, to respond to commands from the Registry accredited Registrars, who already have credentials to the servers. The response shall include appropriate data from the Registry System. An EPP command with “EPP command RTT” 5 times higher than the corresponding SLR will be considered as unanswered. If 51% or more of the EPP testing probes see the EPP service as unavailable during a given time, the EPP service will be considered unavailable.

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.2.1 Local circuit switching capability is defined as: (A) line-side facilities, which include, but are not limited to, the connection between a loop termination at a main distribution frame and a switch line card; (B) trunk-side facilities, which include, but are not limited to, the connection between trunk termination at a trunk-side cross-connect panel and a switch trunk card; (C) switching provided by remote switching modules; and (D) all features, functions, and capabilities of the switch, which include, but are not limited to: (1) the basic switching function of connecting lines to lines, line to trunks, trunks to lines, and trunks to trunks, as well as the same basic capabilities made available to BellSouth’s customers, such as a telephone number, white page listings, and dial tone; and (2) all other features that the switch is capable of providing, including but not limited to customer calling, customer local area signaling service features, and Centrex, as well as any technically feasible customized routing functions provided by the switch. Any features that are not currently available but are technically feasible through the switch can be requested through the BFR/NBR process.

  • Reallocation to a Class with a Lower Salary Range Maximum 1. If the employee meets the skills and abilities requirements of the position and chooses to remain in the reallocated position, the employee retains existing appointment status and has the right to be placed on the Employer’s internal layoff list for the classification occupied prior to the reallocation.

  • Reallocation to a Class with a Higher Salary Range Maximum Upon appointment to the higher class, the employee’s base salary will be increased to a step of the range for the new class that is nearest to five percent (5.0%) higher than the amount of the pre-promotional step, or to the entry step of the new range, whichever is higher.

  • Number Resources, Rate Center Areas and Routing Points 13.1 Nothing in this Agreement shall be construed to limit or otherwise adversely affect in any manner either Party’s right to employ or to request and be assigned any Central Office Codes (“NXX”) pursuant to the Central Office Code Assignment Guidelines and any relevant FCC or Commission orders, as may be amended from time to time, or to establish, by Tariff or otherwise, Rate Center Areas and Routing Points corresponding to such NXX codes.

  • System Availability System Availability percentage is calculated as follows:  Total MinutesintheMonth −Downtime   System Availability%age =  Total MinutesintheMonth *100    System Availability SLA (“SLA”) 99.5% System Availability percentage during each Month for productive versions Credit 2% of Monthly Subscription Fees for each 1% below SLA, not to exceed 100% of Monthly Subscription Fees Excluded Downtime Total Minutes in the Month attributable to: (i) a Scheduled Downtime for which a Regular Maintenance Window is described in Section 4 below, or (ii) any other Scheduled Downtime according to Section 4 for which the customer has been notified at least five (5) business days prior to such Scheduled Downtime or (iii) unavailability caused by factors outside of SAP’s reasonable control, such as unpredictable and unforeseeable events that could not have been avoided even if reasonable care had been exercised. Scheduled Downtime Scheduled Downtime for the applicable Cloud Services to which customer has subscribed is set forth in Section 4 below entitled “Maintenance Windows for Cloud Services”.

  • DNS name server availability Refers to the ability of a public-­‐DNS registered “IP address” of a particular name server listed as authoritative for a domain name, to answer DNS queries from an Internet user. All the public DNS-­‐registered “IP address” of all name servers of the domain name being monitored shall be tested individually. If 51% or more of the DNS testing probes get undefined/unanswered results from “DNS tests” to a name server “IP address” during a given time, the name server “IP address” will be considered unavailable.

  • Distribution and Pool Performance Information Item 1121(a) - Distribution and Pool Performance Information

Time is Money Join Law Insider Premium to draft better contracts faster.