Effectiveness of the specifications Sample Clauses

Effectiveness of the specifications. These specifications are effective after receipt of returned copies with your approved sign.
AutoNDA by SimpleDocs
Effectiveness of the specifications. These specifications are effective after receipt of returned copies with your approved sign. [1] The maximum rating Item Symbol Rating Note 1 Storage temperature range Tsto -30~+70℃ 2 Maximum drive level DL max 1.0 µW max. [2] Recommended Operating Condition Item Symbol Rating Note 1 Operating temperature range Xxxx -10~+60℃ 2 Drive level DL 0.1 µW typ. [3] Erectrical -Characteristics Measurement temperature : 25±2℃ Item Symbol Specifications Conditions 1 Nominal frequency F0 32.768 kHz 2 Frequency tolerance ∆f/f0 ± 20 × 10-6 3 Load capacitance CL 6.0 pF
Effectiveness of the specifications. These specifications are effective after receipt of returned copies with your approved sign. 10.Others This product is completely Pb-free and Halogen-free. [1] Maximum Rating Item Symbol Rating Note 1 Storage temperature range T_stg -55~+125℃ 2 Maximum drive level DL max. 1.0 μ W max. [2] Recommended Operating Condition Item Symbol Rating Note 1 Operating temperature range T_use -40~+85℃ 2 Drive level DL 0.1 μ W typ. [3] Electrical-characteristics Measurement temperature: 25±2℃ Item Symbol Specification Condition 1 Nominal frequency f_nom 32.768 kHz 2 Frequency tolerance f_tol ± 20 × 10-6 3 Load capacitance CL 9.0 pF 4 Motional resistance R1 70 kΩ max. Measured with ATI 4192A Impedance analyzer OSC LEVEL = 0.1V 5 Motional capacitance C1 6 fF typ.
Effectiveness of the specifications. These specifications are effective after receipt of returned copies with your approved sign. 10.Others This product is completely Pb-free and Halogen-free. [1] The maximum rating Item Symbol Rating Note 1 Storage temperature range T_stg -55~+125℃ 2 Maximum drive level DL max. 0.5 μW max. [2] Recommended Operating Condition Item Symbol Rating Note 1 Operating temperature range T_use -40~+85℃ 2 Drive level DL 0.1 μW typ. [3] Electrical-Characteristics Measurement temperature :25±2℃ Item Symbol Specifications Conditions 1 Nominal frequency f_nom 32.768 kHz 2 Frequency tolerance f_tol ± 20 × 10-6 3 Load capacitance CL 12.5 pF 4 Motional resistance R1 70 kΩ max. Measured with ATI 4192A Impedance analyzer OSC LEVEL = 0.1V 5 Motional capacitance C1 3 fF typ. 6 Shunt capacitance C0 1 pF typ. Measured with ATI 4192A Impedance analyzer OSC LEVEL = 0.1V 7 Turnover temperature Ti 25 ± 5℃ Measure this coefficient at 3 points of 10℃、25℃、40℃ using C-MOS circuit 8 Parabolic coefficient B (-3±1) × 10-8/℃2 9 Frequency aging f_age ± 3 × 10-6 /year 25±3℃ First year 10 Insulation resistance IR 500 MΩ min. Measured with ATI 4329A Insulation Resistance Meter Apply DC100V [4] Environment and Mechanical characteristics Item Specifications Conditions 1 High temperature storage -6 Δf/f0 = ±10×10 After storage under 125℃ for 1000 hours, measure at room temperature. *1 *3 2 Low temperature storage -6 Δf/f0 = ±10×10 After storage under -40℃ for 1000 hours, measure at room temperature. *1 *3 3 High temperature and high humidity storage -6 Δf/f0 = ±10×10 After storage under +85±2℃ , 85 % RH for 1000h, measure at room temperature. *1 *3 4 Thermal shock resistance -6 Δf/f0 = ±10×10 Measure at room temperature after 100 cycles. -55℃ ⇔ +125℃ for 30 minutes. *1 *3 5 Mechanical shock resistance -6 Δf/f0 = ±10×10 Measure after 100g-dummy(SII Standard) drop from 1500mm height on the concrete 3directions 10times. *2 7 IR Reflow -6 Δf/f0 = ±10×10 Measure after 2 time reflow under reflow profile specified in page 10 *1 9 Peel strength No peeling-off Pressuring force 10N×10±1sec. according to IEC60068-2-21 *2 10 Bending test No peeling-off Bending: 3mm×5±1sec. Thickness of the testing board: 1mm *2 Note:

Related to Effectiveness of the specifications

  • Effectiveness of Agreement This Agreement shall become effective upon the execution and delivery hereof by the parties hereto.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Effectiveness of Contract This Contract shall come into effect on the date the Contract is signed by both parties or such other later date as maybe stated in the SCC.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • Implementation Specifications 1. The accounting shall contain the date, nature, and purpose of such disclosures, and the name and address of the person or agency to whom the disclosure is made.

  • Accessibility of Web-Based Information and Applications For State Agency Authorized User Acquisitions: Any web-based information and applications development, or programming delivered pursuant to the contract or procurement, will comply with New York State Enterprise IT Policy NYS-P08-005, Accessibility of Web-Based Information and Applications as follows: Any web-based information and applications development, or programming delivered pursuant to the contract or procurement, will comply with New York State Enterprise IT Policy NYS-P08- 005, Accessibility of Web-Based Information and Applications as such policy may be amended, modified or superseded, which requires that state agency web-based information and applications are accessible to persons with disabilities. Web-based information and applications must conform to New York State Enterprise IT Policy NYS-P08-005 as determined by quality assurance testing. Such quality assurance testing will be conducted by the State Agency Authorized User and the results of such testing must be satisfactory to the Authorized User before web-based information and applications will be considered a qualified deliverable under the contract or procurement.

  • Inclusion and accessibility The institution will provide support to incoming mobile participants with fewer opportunities, according to the requirements of the Erasmus Charter for Higher Education. Information and assistance can be provided by the following contact points and information sources: Country Available infrastructure adjusted for people with Description of infrastructure Contact e-mail and phone Website for information FROM TO CZ PL --- --- --- PL CZ --- --- xxxx://xxx.xxxxxxxxx.xxxx.xx/?la ng=en Country Available support services for people with Description of infrastructure Contact e-mail and phone Website for information FROM TO CZ PL --- --- --- PL CZ --- --- ---

  • Unbundled Loop Modifications (Line Conditioning 2.5.1 Line Conditioning is defined as routine network modification that BellSouth regularly undertakes to provide xDSL services to its own customers. This may include the removal of any device, from a copper Loop or copper Sub-loop that may diminish the capability of the Loop or Sub-loop to deliver high-speed switched wireline telecommunications capability, including xDSL service. Such devices include, but are not limited to, load coils, excessive bridged taps, low pass filters, and range extenders. Excessive bridged taps are bridged taps that serves no network design purpose and that are beyond the limits set according to industry standards and/or the XxxxXxxxx XX 00000.

  • Availability of Licensed Materials Upon the Effective Date of this Agreement, Licensor will make the Licensed Materials available to the Licensee, the Participating Institutions and Authorized Users.

Time is Money Join Law Insider Premium to draft better contracts faster.