Testing of the Transformation BCDR Plan Sample Clauses

Testing of the Transformation BCDR Plan. 8.1 The Contractor shall test the Transformation BCDR Plan on a regular basis (and in any event not less than once in every Contract Year). Subject to Paragraph 8.2, the Framework Authority may require the Contractor to conduct additional tests of some or all aspects of the Transformation BCDR Plan at any time where the Framework Authority considers it necessary, including where there has been any change to the Available Services or any underlying business processes, or on the occurrence of any event which may increase the likelihood of the need to implement the Transformation BCDR Plan.
AutoNDA by SimpleDocs

Related to Testing of the Transformation BCDR Plan

  • TESTING OF THE BCDR PLAN The Service Provider shall test the BCDR Plan on a regular basis (and in any event not less than once in every Contract Year). Subject to paragraph 6.2, the Purchaser may require the Service Provider to conduct additional tests of some or all aspects of the BCDR Plan at any time where the Purchaser considers it necessary, including where there has been any change to the Services or any underlying business processes, or on the occurrence of any event which may increase the likelihood of the need to implement the BCDR Plan. If the Purchaser requires an additional test of the BCDR Plan, it shall give the Service Provider written notice and the Service Provider shall conduct the test in accordance with the Purchaser's requirements and the relevant provisions of the BCDR Plan. The Service Provider's costs of the additional test shall be borne by the Purchaser unless the BCDR Plan fails the additional test in which case the Service Provider's costs of that failed test shall be borne by the Service Provider. The Service Provider shall undertake and manage testing of the BCDR Plan in full consultation with the Purchaser and shall liaise with the Purchaser in respect of the planning, performance, and review, of each test, and shall comply with the reasonable requirements of the Purchaser in this regard. Each test shall be carried out under the supervision of the Purchaser or its nominee. The Service Provider shall ensure that any use by it or any Sub-contractor of “live” data in such testing is first approved with the Purchaser. Copies of live test data used in any such testing shall be (if so required by the Purchaser) destroyed or returned to the Purchaser on completion of the test. The Service Provider shall, within twenty (20) Working Days of the conclusion of each test, provide to the Purchaser a report setting out: the outcome of the test; any failures in the BCDR Plan (including the BCDR Plan's procedures) revealed by the test; and the Service Provider's proposals for remedying any such failures. Following each test, the Service Provider shall take all measures requested by the Purchaser, (including requests for the re-testing of the BCDR Plan) to remedy any failures in the BCDR Plan and such remedial activity and re-testing shall be completed by the Service Provider, at no additional cost to the Purchaser, by the date reasonably required by the Purchaser and set out in such notice. For the avoidance of doubt, the carrying out of a test of the BCDR Plan (including a test of the BCDR Plan’s procedures) shall not relieve the Service Provider of any of its obligations under this Contract. The Service Provider shall also perform a test of the BCDR Plan in the event of any major reconfiguration of the Services or as otherwise reasonably requested by the Purchaser.

  • Staffing Plan 8.l The Board and the Association agree that optimum class size is an important aspect of the effective educational program. The Polk County School Staffing Plan shall be constructed each year according to the procedures set forth in Board Policy and, upon adoption, shall become Board Policy.

  • Post-Commercial Operation Date Testing and Modifications Each Party shall at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice as may be necessary to ensure the continued interconnection of the Large Generating Facility with the Participating TO’s Transmission System in a safe and reliable manner. Each Party shall have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.

  • Performance Improvement Plan timely and accurate completion of key actions due within the reporting period 100 percent The Supplier will design and develop an improvement plan and agree milestones and deliverables with the Authority

  • Commercial Operation Date Testing and Modifications Prior to the Commercial Operation Date, the Connecting Transmission Owner shall test the Connecting Transmission Owner’s Attachment Facilities and System Upgrade Facilities and System Deliverability Upgrades and Developer shall test the Large Generating Facility and the Developer Attachment Facilities to ensure their safe and reliable operation. Similar testing may be required after initial operation. Developer and Connecting Transmission Owner shall each make any modifications to its facilities that are found to be necessary as a result of such testing. Developer shall bear the cost of all such testing and modifications. Developer shall generate test energy at the Large Generating Facility only if it has arranged for the injection of such test energy in accordance with NYISO procedures.

  • Implementation of Strategic Plan Goals This Agreement supports the County’s Strategic Plan, Goal 1, Operational Effectiveness/Fiscal Sustainability. This Agreement will provide revenue reimbursement to the Department for services rendered.

  • Selection of Consulting Services 7. Except as ADB may otherwise agree, and except as set forth in the paragraph below, the Borrower shall apply quality- and cost-based selection for selecting and engaging Consulting Services. Schedule 4

  • EFFECTIVE DATE/COMPLETION OF SERVICES 3.1 Notwithstanding any provision of this Agreement to the contrary, and subject to the approval of the Governor and Executive Council of the State of New Hampshire, if applicable, this Agreement, and all obligations of the parties hereunder, shall become effective on the date the Governor and Executive Council approve this Agreement as indicated in block 1.17, unless no such approval is required, in which case the Agreement shall become effective on the date the Agreement is signed by the State Agency as shown in block 1.13 (“Effective Date”).

  • Campus Program Dr. X. Xxx Xxxxxx, Chairperson of the Department of Management & Business Administration, (000) 000-0000 Division of Continuing Education: Academic advisor at center where student intends to transfer MAXIMUM NUMBER OF COMMUNITY COLLEGE STUDENTS TO BE ADMITTED: open BASIS FOR DETERMINING ADMISSION IF MORE THAN THE MAXIMUM NUMBER OF COMMUNITY COLLEGE STUDENTS APPLY: N/A GENERAL ADMISSION REQUIREMENTS TO THE INDEPENDENT INSTITUTION: Students applying to the university campus program are considered for admission on the basis of their secondary school record and results of the SAT or ACT examinations. For acceptance to the Division of Continuing Education, a prospective student must have a high school diploma or a General Equivalency Diploma. ADMISSION REQUIREMENTS TO THE MAJOR/PROGRAM OF STUDY: None beyond general admission requirements. PROGRAM OF STUDY TO BE TAKEN AT THE COMMUNITY COLLEGE: Complete Associate of Arts degree. Total Academic Hours: 60 PROGRAM OF STUDY AT SAINT XXX UNIVERSITY: (to include 39 hours of upper level credit and 30 hours of residency, 15 of which must be taken in the major)

  • Modifications and Updates to the Wire Center List and Subsequent Transition Periods 2.1.4.12.1 In the event BellSouth identifies additional wire centers that meet the criteria set forth in Section 2.1.4.5, but that were not included in the Initial Wire Center List, BellSouth shall include such additional wire centers in a carrier notification letter (CNL). Each such list of additional wire centers shall be considered a “Subsequent Wire Center List”.

Time is Money Join Law Insider Premium to draft better contracts faster.