Sampling location and frequency Sample Clauses

Sampling location and frequency. Data collection will occur between July 2016 and October 2017. Monitoring locations are provided in Table 6 and Figure 6. Continuous temperature collection: • Water temperature loggers will be deployed to log every 30 minutes in locations where representative temperature data may be obtained throughout the entire monitoring period. It is anticipated that 8 temperature loggers will be deployed and temperature will also be recorded at 2 locations with water level transducers. Continuous stage data collection: • Water level transducers will be deployed to log every 30 minutes at two locations (Table 6). Substrate condition: • Substrate condition in the connected, northern side channel will be assessed during low flow conditions, in the summer or fall of 2016, at the location indicated in Figure 6. Table 6. Monitoring sites and parameter to be measured. Site Descriptor Latitude Longitude Parameter Right bank downstream 46.319184° -119.486881° Temperature Right bank 46.318045° -119.486842° Temperature Right bank upstream 46.317294° -119.485130° Temperature Logger in river 46.317150° -119.486950° Temperature Culvert outlet 46.317117° -119.486983° Temperature and stage Side channel inlet 46.316537° -119.482935° Temperature and stage Mid-side channel 46.316167° -119.483450° Substrate Chase culvert 46.315582° -119.486932° Temperature Spring 2 46.315033° -119.486900° Temperature Oxbow head 46.314656° -119.484358° Temperature Spring 1 46.314533° -119.486267° Temperature Figure 6. Map of monitoring locations.
AutoNDA by SimpleDocs

Related to Sampling location and frequency

  • Scaling Location Forest Service shall provide Scaling services at the Scaling site(s) shown in A10. The Scaling site(s) shown in A10 normally will be a non-exclusive site where more than one National Forest timber sale Purchaser may be served. Purchaser may request, in writing, an alternate Scal- ing site, such as at a private mill yard, private truck ramp, or a privately operated log transfer facility. Contracting Of- ficer may approve an alternate Scaling site, when Con- tracting Officer determines that Scaling conditions at an alternate site are acceptable. Such conditions shall in- clude at a minimum:

  • Access to Work Locations Reasonable access to employee work locations shall be granted officers of the Association and their officially designated representatives for the purpose of processing grievances or contacting members of the Association concerning business within the scope of representation. Such officers or representatives shall not enter any work location without the consent of the City Manager. Access shall be restricted so as not to interfere with the normal operations of the department or with established safety or security requirements. Solicitation of membership and activities concerned with the internal management of the Association, such as collecting dues, holding membership meetings, campaigning for office, conducting elections and distributing literature, shall not be conducted during working hours.

  • Data Location 1.1. The CONTRACTOR shall not store or transfer non-public COUNTY data outside of the United States. This includes backup data and Disaster Recovery locations. The CONTRACTOR will permit its personnel and contractors to access COUNTY data remotely only as required to provide technical support. (Remote access to data from outside the continental United States is prohibited unless approved in advance and in writing by the County.)

  • Inspection and Testing Each Constructing Entity shall cause inspection and testing of the Interconnection Facilities that it constructs in accordance with the provisions of this section. The Construction Parties acknowledge and agree that inspection and testing of facilities may be undertaken as facilities are completed and need not await completion of all of the facilities that a Constructing Entity is building.

  • Vaccination and Inoculation (a) The Employer agrees to take all reasonable precautions, including in-service seminars, to limit the spread of infectious diseases among employees.

  • Equipment Testing and Inspection 2.1.1 The Interconnection Customer shall test and inspect its Small Generating Facility and Interconnection Facilities prior to interconnection. The Interconnection Customer shall notify the NYISO and the Connecting Transmission Owner of such activities no fewer than five Business Days (or as may be agreed to by the Parties) prior to such testing and inspection. Testing and inspection shall occur on a Business Day. The Connecting Transmission Owner may, at its own expense, send qualified personnel to the Small Generating Facility site to inspect the interconnection and observe the testing. The Interconnection Customer shall provide the NYISO and Connecting Transmission Owner a written test report when such testing and inspection is completed. The Small Generating Facility may not commence parallel operations if the NYISO, in consultation with the Connecting Transmission Owner, finds that the Small Generating Facility has not been installed as agreed upon or may not be operated in a safe and reliable manner.

  • Service Location and Equipment The AGENCY must request in writing and said request must be approved in writing by the COUNTY’S Manager of the CCC or designee, prior to any change in the dates, times, and locations of services provided in this Contract.

  • Inspection and Tests 3.8.1 The Procuring entity or its representative shall have the right to inspect and/or to test the goods to confirm their conformity to the Contract specifications. The Procuring entity shall notify the tenderer in writing in a timely manner, of the identity of any representatives retained for these purposes.

  • Reporting of Metered Data and Parameters 7.2.1 The grid connected Solar PV power plants will install necessary equipment for regular monitoring of solar irradiance (including GHI, DHI and solar radiation in the module plane), ambient air temperature, wind speed and other weather parameters and simultaneously for monitoring of the electric power (both DC and AC) generated from the Project.

  • AIN Selective Carrier Routing for Operator Services, Directory Assistance and Repair Centers 4.3.1 BellSouth will provide AIN Selective Carrier Routing at the request of <<customer_name>>. AIN Selective Carrier Routing will provide <<customer_name>> with the capability of routing operator calls, 0+ and 0- and 0+ NPA (LNPA) 555-1212 directory assistance, 1+411 directory assistance and 611 repair center calls to pre-selected destinations.

Time is Money Join Law Insider Premium to draft better contracts faster.